• Title/Summary/Keyword: T1 relaxation time

Search Result 140, Processing Time 0.023 seconds

Discriminating the Geographical Origin of Sesame Seeds by Low Field NMR (Low field NMR을 이용한 참깨의 원산지 판별)

  • Rho, Jeong-Hae;Lee, Sun-Min
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1062-1066
    • /
    • 2002
  • Low field NMR was employed to discriminate the geographical origin of sesame seeds from Sudan, China, and Korea. Sudan sesame seeds had the lowest contents of moisture and crude fat. Chemical components of Korean and Chinese sesame seeds were similar, whereas relaxation times $(T_1-IR,\;T_1-SR)$ measeured through spin-lattice relaxation pluse techniques using 20 MHz NMR showed significant difference (p0.05). Canonical discriminant analysis could be used to identify the habitat of sesame seeds with over 90% accuracy of NMR results. Non-destructive and fast NMR techniques can be applied to classify Korean sesame seeds from those of other origins.

The Effect of Relaxation Technique on Reduction of Postoperative Pain (이완술 사용이 수술후 동통 감소에 미치는 영향)

  • 박정숙
    • Journal of Korean Academy of Nursing
    • /
    • v.15 no.1
    • /
    • pp.76-96
    • /
    • 1985
  • Postoperative pain is one of the most frequently occurred pain in hospitals, but it has been underestimated because it is only a part of postoperative physiological Process and may disappear in time. It is necessary that nurses me the relaxation technique, planning and implementing by themselves independently, to reduce this postoperative pain. This study is aimed at showing the effect of relaxation technique on reduction of postoperative pain, and exploring the factors influencing postoperative. pain Fifty-seven patients with abdominal surgery who admitted in attacked D Medical Center to K University in Daegu have been studied. Of them twenty-nine were experimental group and the remaining twenty-eight were control group. This study has been conducted for collecting data through interviews and observation from August 23 to October 24, 1984. The tools of this study were two kinds: Postoperative Pain Scale is obtained from a review of references by the researcher, and relaxation technique, designed to use postoperative setting adequately, is also obtained from a review of references by the researcher. After confiriming no significant differences between the two groups, the hypotheses were statistically verified by x²-test, t-test, and pearson Correlation Coefficient. The results of this study are summerized as follows; * The nam hypothesis that the experimental group who use relaxation technique will have less degree of postoperative pain than the control group who don't use relaxation technique is devided into three sub-hypotheses. 1. The first sub-hypothesis that the experimental group will have less score of postoperative pain than control group was accepted (t=7.810, p <.01). Even with controlling pain threshold, showing difference in some degree between the two groups, the experimental group has less score of postoperative pain than the control group. Therefore this confirms the acceptance of the first sub-hypothesis more strongly. 2. The second sub-hypothesis that the expermental group will have less frequency of analgesics than the control group is accepted (x²=9.85, p <.01). 3. The third sub-hypothesis that the experimental group will have less variation of pulse, respiration, and blood pressure between pre End post operative periods than the control group is rejected. So this hypothesis is reverified through comparing the variation of pulse, respiration, and blood pressure between pre and post changing Position to measure the pure effect of relaxation technique. pulse and respiration is significantly lowered in the experimental group (t=7.209, p<.01, t=3.473, p<.01), but systolic and diastolic blood pressure is not different significantly between the two groups (t= 1.309, p>.05, t=1. 727 p>.05). Therefore the third sub-hypothesis is partially accepted. Conclusively, the researcher thinks that it is necessary that nurses should provide patients with relaxation technique to reduce postoperative pain, and to increase independence of nursing.

  • PDF

Thermodynamic and Physical Properties of (NH4)2MnCl4·2H2O by Nuclear Magnetic Resonance Relaxation Times

  • Kim, Yoo Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.2
    • /
    • pp.40-45
    • /
    • 2019
  • The phase transition temperatures and thermodynamic properties of $(NH_4)_2MnCl_4{\cdot}2H_2O$ grown by the slow evaporation method were studied using differential scanning calorimetry and thermogravimetric analysis. A structural phase transition occurred at temperature $T_{C1}$ (=264 K), whereas the changes at $T_{C2}$ (=460 K) and $T_{C3}$ (=475 K) seemed to be chemical changes caused by thermal decomposition. In addition, the chemical shift and the spin-lattice relaxation time $T_{1{\rho}}$ were investigated using $^1H$ magic-angle spinning nuclear magnetic resonance (MAS NMR), in order to understand the role of $NH_4{^+}$ and $H_2O$. The rise in $T_{1{\rho}}$ with temperature was related to variations in the symmetry of the surrounding $H_2O$ and $NH_4{^+}$.

T1-, T2-weighted, and FLAIR Imaging: Clinical Application (T1, T2강조영상, FLAIR영상의 임상 적용)

  • Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • T1-, and T2-weighted imagings and FLAIR (fluid attenuated inversion recovery) imaging are fundamental imaging methods in the brain. T1-weighted imaging is a spin-echo sequence with short TR and short TE and produces the tissue contrast by different T1 relaxation times. In other words, short TR maximizes the difference of the longituidinal magnetization recovery between the tissues. T2-weighted imaging is a spin-echo sequence with long TR and long TE and produces the tissue contrast by different T2 relaxation times. Long TE maximizes the difference of the transverse magnetization decay between the tissues. FLAIR is an inversion recovery sequence using 180 degree inversion pulse. 2500 msec of inversion time is applied to suppress the CSF signal.

  • PDF

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Detection of Iron Nanoparticles using Nuclear Magnetic Resonance Relaxometry and Inverse Laplace Transform

  • Kim, Seong Min
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: Rapid detection of bacteria is very important in agricultural and food industries to prevent many foodborne illnesses. The objective of this study was to develop a portable nuclear magnetic resonance (NMR)-based system to detect foodborne pathogens (E. coli). This study was focused on developing a method to detect low concentrations of magnetic nanoparticles using NMR techniques. Methods: NMR relaxometry was performed to examine the NMR properties of iron nanoparticle mixtures with different concentrations by using a 1 T permanent magnet magnetic resonance imaging system. Exponential curve fitting (ECF) and inverse Laplace transform (ILT) methods were used to estimate the NMR relaxation time constants, $T_1$ and $T_2$, of guar gum solutions with different iron nanoparticle concentrations (0, $10^{-3}$, $10^{-4}$, $10^{-5}$, $10^{-6}$, and $10^{-7}M$). Results: The ECF and ILT methods did not show much difference in these values. Analysis of the NMR relaxation data showed that the ILT method is comparable to the classical ECF method and is more sensitive to the presence of iron nanoparticles. This study also showed that the spin-spin relaxation time constants acquired by a Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence are more useful for determining the concentration of iron nanoparticle solutions comparwith the spin-lattice relaxation time constants acquired by an inversion recovery pulse sequence. Conclusions: We conclude that NMR relaxometry that utilizes CPMG pulse sequence and ILT analysis is more suitable for detecting foodborne pathogens bound to magnetic nanoparticles in agricultural and food products than using inversion recovery pulse sequence and ECF analysis.

Study on Viscoelastic Properties of Rice Plant (벼줄기의 점탄성(粘彈性) 특성(特性)에 관(關)한 연구(硏究))

  • Huh, Yun Kun
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.2
    • /
    • pp.255-264
    • /
    • 1986
  • The objectives of this study were to examine the viscoelastic behaviour of stem samples of rice in force-relaxation and rheological model to represent its relaxation behaviour, and to study the effects of rate of deformation and initial deformation on the relaxation time. The results were as follows; 1. In the process of loading and unloading, there is any plastic deformation so called elasto-plastic hysterisis. 2. Loading and unloading of stem of rice for several cycles has also shown the reduction of plastic or residual deformation and work hardening. 3. The relaxation behaviour of stem of rice in compression may be described by a generalized Maxwell model consisting of three Maxwell units in parallel. The rheological equation of such a model is given as $$F(t)=C_1e^{{-t/{\tau}}_1}+C_2e^{{-t/{\tau}}_2}+C_3e^{{-t/{\tau}}_3}$$ 4. Force relaxation always increased with increasing rates of deformation and initial deformation.

  • PDF

Feasibility of Novel Three-Dimensional Magnetic Resonance Fingerprinting of the Prostate Gland: Phantom and Clinical Studies

  • Dongyeob Han;Moon Hyung Choi;Young Joon Lee;Dong-Hyun Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1332-1340
    • /
    • 2021
  • Objective: To evaluate the feasibility of a new three-dimensional (3D) MR fingerprinting (MRF) technique for the prostate gland by conducting phantom and clinical studies. Materials and Methods: The new 3D MRF technique used in this study enables quick data acquisition and has a high resolution. For the phantom study, the MRF T1 and T2 values in an in-house phantom were compared with those of goldstandard mapping methods using linear regression analysis. For the clinical study, we evaluated 90 patients who underwent prostate imaging with MRF for suspected prostate cancer between September 2019 and February 2020. The mean T1 and T2 values were compared in the peripheral zone, transition zone, and focal lesions using paired t tests. The differences in the T1 and T2 values according to cancer aggressiveness were evaluated using one-way analysis of variance. Results: In the phantom study, the MRF T1 and T2 values showed a perfect correlation with the gold-standard T1 and T2 values (R > 0.99). In the clinical study, the T1 and T2 values in the peripheral zone were significantly higher than those in the transitional zone (p < 0.001, both). The T1 and T2 values in prostate cancer were significantly lower than those in the peripheral and transitional zones. The higher the grade of cancer, the lower the T2 values. Conclusion: The T1 and T2 values obtained from the 3D MRF showed a perfect correlation with the gold standard values in the phantom study. Differences in the T1 and T2 values among the different zones of the prostate gland were identified using 3D MRF in patients.

Nuclear Magnetic Resonance Study of 23Na in NaMgCl3 Single Crystal (NaMgCl3 단결정 내의 23Na 원자핵에 대한 핵 자기 공명 연구)

  • Yeom, Tae Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.185-188
    • /
    • 2015
  • We have investigated nuclear magnetic resonance of $^{23}Na$ nucleus in $NaMgCl_3$ single crystal in the temperature range 200 K~410 K using FT-NMR spectrometer. The spin-lattice relaxation times $T_1$ of $^{23}Na$ nucleus residing at cubic symmetry in the host crystal was measured as a function of temperature. The $T_1$ of $^{23}Na$ nucleus decreased with increasing temperature. The nuclear spin-lattice relaxation rate $1/T_1$ of $^{23}Na$ in $NaMgCl_3$ single crystal was proportional to the temperature T. This behavior is explained with the characteristic feature of the direct process between the nuclear spins and single phonon, $1/T_1$ being proportional to the absolute temperature. The activation energy calculated was $E_a=4.82J/mol$.

Nuclear Magnetic Relaxation in Anisotropic Heisenberg Antiferromagnet $MnCl_{2}.4H_{2}O$ (Heisenberg 반강자성체 $MnCl_{2}.4H_{2}O$의 핵자기완화 연구)

  • Chang Hoon Lee;Cheol Eui Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.54-57
    • /
    • 1995
  • We have studied the room temperature $^{1}H$ nuclear magnetic relaxation in anisotropic antiferromagnet $MnCl_{2}.4H_{2}O$ using a wide range of $^{1}H$ NMR (nuclear magnetic resonance) field. Being a system of dense paramagnetic $Mn^{++}$ ions at room temperature, $MnCl_{2}.4H_{2}O$ shows some features that can be expected from dilute paramagnetic systems, as well as some results that drastically deviate from the dilute paramagnetic approximations. Besides, $^{1}H$ nuclei exhibit an anomalous deviation in the spin-lattice relaxation time ($T_{1}$) around the field of 0.7 T.

  • PDF