• Title/Summary/Keyword: T1영상

Search Result 1,502, Processing Time 0.032 seconds

A study on urban heat islands over the metropolitan Seoul area, using satellite images (원격탐사기법에 의한 도시열섬 연구)

  • ;Lee, Hyoun-Young
    • Journal of the Korean Geographical Society
    • /
    • v.40
    • /
    • pp.1-13
    • /
    • 1989
  • The brightness temperature from NOAA AVHRR CH 4 images was examined for the metropolitan Seoul area, the capital city of Korea, to detect the characteristics of the urban heat island for this study. Surface data from 21 meteorological stations were compared with the brightness temperatures Through computer enhancement techniques, more than 20 heat islands could be recognized in South Korea, with 1 km spatii resolution at a scale of 1: 200, 00O(Fig. 3, 4 and 6). The result of the analysis of AVHRR CH 4 images over the metropolitan Seoul area can be summerized as follows (1) The pattern of brightness temperature distribution in the metropolitan Seoul area shows a relatively strong temperature contrast between urban and rural areas. There is some indication of the warm brightness temperature zone characterrizing built-up area including CBD, densely populated residential district and industrial zone. The cool brightness temperature is asociaed with the major hills such as Bukhan-san, Nam-san and Kwanak-san or with the major water bodies such as Han-gang, and reservoirs. Although the influence of the river and reservoirs is obvious in the brightness temperauture, that of small-scaled land use features such as parks in the cities is not features such as parks in the cities is not apperent. (2) One can find a linerar relationshop between the brightenss temperature and air temperature for 10 major cities, where the difference between two variables is larger in big cities. Though the coefficient value is 0.82, one can estimate that factors of the heat islands can not be explained only by the size of the cities. The magnitude of the horizontal brightness temperature differences between urban and rural area is found to be greater than that of horizontal air temperature difference in Korea. (3) Also one can find the high heat island intensity in some smaller cities such as Changwon(won(Tu-r=9.0$^{\circ}$C) and Po-hang(Tu-r==7.1$^{\circ}$~)T. he industrial location quotient of Chang-won is the second in the country and Po-hang the third. (4) A comparision of the enhanced thermal infrared imageries in 1986 and 1989, with the map at a scale of 1:200, 000 for the meotropolitan Seoul area showes the extent of possible urbanization changes. In the last three years, the heat islands have been extended in area. zone characterrizing built-up area including (5) Although the overall data base is small, the data in Fig. 3 suggest that brightness tempeautre could ge utilized for the study on the heat island characteristics. Satellite observations are required to study and monitor the impact of urban heat island on the climate and environment on global scale. This type of remote sensing provides a meams of monitoring the growth of urban and suburban aeas and its impact on the environment.

  • PDF

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Marrow Conversion Pattern of the Femora and Acetabulum Around Hip Joints According to Age Group : MR Evaluation (연령에 따른 고관절주위 대퇴골 및 절구뼈 골수전환 양상 : MR 평가)

  • Lee, In-Sook;Choi, Hyun-Wook;Seo, Im-Jeong;Woo, Sung-Ku;Moon, Tae-Yong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • Purpose : Marrow edema and fatty degeneration of the hip joint bones could be initial and late signs in hip joint and its bone diseases respectively, which might be differentiated from age-related marrow conversion pattern. So authors have investigated normal marrow conversion pattern of the femur and acetabulum around the hip joints. Materials and methods : Three coronal MR images of 288 hip joint bones in 144 subjects, aged 2 days to 76 years divided to 8 groups every 10 years, were retrospectively analysed for the location and appearance of the converted yellow marrow. The converted yellow marrow were divided to head, neck, and trochanter in the proximal femur and below and above 50% in acetabulum of the hip. Results : The most common type of marrow conversion is the converted yellow marrow in the entire proximal femur and below 50% of acetabulum of the hip. We observed the start of marrow conversion in just before and after 2 years old and stopped at just before and after 20 years old. Conclusion : The understanding of age-related marrow conversion pattern of the hip joint bones would provide some information for differentiation from pathologic condition of them such as edema, fatty degeneration, metastasis, or leukemia.

  • PDF

Spreading of motion aftereffect for rotational motion: Evidence of adaptation of global motion detector (회전 운동 잔여 효과의 확산 현상: 전역적 운동 탐지기의 순응에 대한 증거)

  • Kham Keetaek
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.1
    • /
    • pp.17-27
    • /
    • 2005
  • After prolonged viewing of a moving pattern, a stationary pattern can appear to move in the opposite direction, a phenomenon known as motion aftereffect (MAE). Unlike the classical explanation MAE was not confined to an adapted region; instead it can spread to an adjacent region, which was not adapted previously. In order to examine the relative locus of the mechanism responsible for MAE spreading, a rotating harmonic spiral pattern was presented as an adapting stimulus within an annulus window, and then the duration of MAE was measured in both the adapted annulus region and the non-adapted inner region. Two different kinds of test patterns were used: the same and mirror images of the original adapting pattern. An interesting characteristic of a harmonic spiral is that the orientation of a contour at a given location is different from thar of its mirror image by 90 degrees, and consequently the adapting effect of local motion detector is not expected to occur in the mirror image. The results showed that MAE duration in an adapted region was longer in the same image condition than in its mirror image condition, while MAE duration in an non-adapted region was not found to be different between those two different image conditions. These results suggest that MAE spreading might be produced by the adaptation of global motion detectors, not by local motion detectors.

  • PDF

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

A Study on the Habitat Mapping of Meretrix lyrata Using Remote Sensing at Ben-tre Tidal Flat, Vietnam (원격탐사를 활용한 베트남 Ben-tre 갯벌의 Meretrix lyrata 서식지 매핑 연구)

  • Hwang, Deuk Jae;Woo, Han Jun;Koo, Bon Joo;Choi, Jong-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.975-987
    • /
    • 2021
  • Potential habitat mapping of Meretrix lyrata which is found in large parts of South East Asian tidal flat was carried out to find out causes of collective death. Frequency Ratio (FR) method, one of geospatialstatistical method, was employed with some benthic environmental factors; Digital elevation model (DEM) made from Landsat imagery, slope, tidal channel distance, tidal channel density, sedimentary facesfrom WorldView-02 image. Field survey was carried out to measure elevation of each station and to collect surface sediment and benthos samples. Potential habitat maps of the all clams and the juvenile clams were made and accuracy of each map showed a good performance, 76.82 % and 69.51 %. Both adult and juvenile clams prefer sand dominant tidal flat. But suitable elevation of adult clams is ranged from -0.2 to 0.2 m, and that of juvenile clams is ranged from 0 to 0.3 m. Tidal channel didn't affect the habitat of juvenile clams, but it affected the adult clams. In the furtherstudy, comparison with case of Korean tidal flat will be carried out to improve a performance of the potential habitat map. Change in the benthic echo-system caused by climate change will be predictable through potential habitat mapping of macro benthos.