• Title/Summary/Keyword: T-testing

Search Result 1,530, Processing Time 0.034 seconds

Consideration on data acquisition and analysis system for using short-circuit tests (디지털 측정 및 분석장치의 적용에 관한 연구)

  • Kim, M.H.;Suh, Y.T.;Kim, D.W.;Kang, Y.S.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.38-40
    • /
    • 2001
  • Measuring technology based on the computer and software is used worldwideiy by the aids of remarkably improved digital technology and measuring devices, and the electro- magnetic interference due to high currents and high voltages is being solved by the helps of applied optic instrumentation technology. The automatic acquisition, analysis and storage system of test data is available for utilizing the numerical computation technology. The measuring accuracy and testing efficiency are thus much higher because of the developed technologies. In this paper, the construction of data acquisition system in KERI including measuring devices and its application to the short circuit test are described, and additionally the algorithm of the analyzing program for the automatic process of test data and the results of analyses are described.

  • PDF

The system development for measuring and analyzing operating characteristics of high-voltage circuit-breaker (고압 차단기 동작특성 측정 및 분석용 시스템 개발)

  • Yun, Ji-Ho;Kang, Yun-Sik;Kim, Hong-Ryong;Park, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.77-78
    • /
    • 2007
  • 국제규격에 따라 VCB(vacuum circuit breaker), ACB(air circuit breaker), 등과 같은 전력기기들의 기계적 동작 시험 시, 시험전후의 개폐시간, 개폐속도, 동작코일전류크기, 등과 같은 특성을 측정하고 이들의 변화정도를 평가하여 시험결과를 판단한다. 그러나 시험 중에는 이러한 동작특성들을 측정하지 않기 때문에, 시험 중에 실패하는 경우, 원인 규명에 많은 어려움이 따른다. 이러한 문제를 해결하기 위해, LS산전 PT&T(Power Testing & Technology Institutes)는 시험전후뿐만 아니라 전체시험횟수 동안 동작특성을 측정하고, 이들의 변화추이를 분석할 수 있는 시스템을 구축하고, 관련 소프트웨어를 개발하였다. 본 논문에서는 개발 내용과 결과를 소개하고자 한다.

  • PDF

Active Compliance Control for the Rehabilitation Robot with Cable Driven Transmission (케이블 구동 메커니즘을 이용한 재활 로봇의 능동 컴플라이언스 제어)

  • Kang, Sang-Hoon;Chang, Pyung-Hun;Park, Hyung-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1823-1832
    • /
    • 2004
  • In this paper, we proposed a TDC based F/T sensorless active compliance control algorithm for a rehabilitation robot (KARES II). The preference of compliance of the disabled is presented by clinical testing at Korea National Rehabilitation Center with the disabled. The KARES II was designed to work 12 predefined tasks which are very essential for helping the disabled. Among the tasks, some contact tasks between the robot and the disabled exist. Therefore, TDC based F/T sensorless compliance control algorithm is developed for these tasks without additional cost. We verified the proposed algorithm with experiment. Also for the practical use, suitable compliance for contact tasks is chosen by clinical testing at Korea National Rehabilitation Center.

Application Program Specialized for High Power Testing Station (대전력시험 전용 응용 프로그램)

  • Oh, Seung-Ryle;Park, Ji-Hun;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.150-152
    • /
    • 2008
  • It is necessary to improve the time efficiency in the high power testing station because tests are mainly performed by high-priced equipment. Minimizing a human error through building the database of relevant standards is possible to expect reliable tests. And also, application program that is properly customized for the certain laboratory's power system will help test engineer to easily analyze the phenomenon that is happened in short-circuit and load switching tests. This paper introduces the several functions of the application program that is developed in order to realize these requirements.

  • PDF

Assessment of Insulation Condition in Gas Turbine Generator Stator Windings (가스터빈 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Yang, Gyu-Hyun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

Vibration Analysis of a Cable Supported Wind Turbine Tower Model (케이블 지지된 풍력발전기 타워 구조 모델의 진동해석)

  • Kim, Seock-Hyun;Park, Mu-Yeol;Cui, C.X.
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.47-53
    • /
    • 2007
  • A theoretical model based on Rayleigh-Ritz method is proposed to predict the resonance frequency of a W/T(Wind Turbine) tower structure supported by guy cables. In order to verify the validity of the theoretical model, a reduced W/T tower system is manufactured and tested. Frequency response and mode data are determined by modal testing and finite element analysis is performed to calculate the natural frequency of the tower model. Numerical and experimental results are compared with those by the theoretical analysis. Parametric study by the theoretical model shows how the cable tension and cable elasticity influence the resonance frequency of the W/T tower structure. Finally, vibration response under various rotating speed is investigated to examine the possibility of severe resonance.

  • PDF

Impedance Characteristics Analysis of Eddy Current Testing Sensor for T/R Probe Design (와전류탐상 T/R 프로브 제작을 위한 센서의 임피던스 특성해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.566-569
    • /
    • 2008
  • 와전류탐상(ECT) Transmit-Receive 프로브를 이용한 ECT 방법은 센서코일의 유도기전력의 변화를 관찰하여 피검사체의 결함이나 특성의 변화를 탐지해내는 방법이다. ECT T/R 프로브는 여러 개의 Pancake 코일로 구성되어있고, 각각의 코일은 Transmit 코일과 Receive 코일로 나뉜다. 본 논문은 실제 TH 프로브 제작에 앞서 동일한 특성을 갖는 와전류센서를 설계 및 제작하여 그 특성을 파악하였다. 와전류센서에 인가되는 시험주파수와 Lift-off의 변화에 대한 특성을 파악하고 와전류센서의 임피던스값을 산출하여 정규화 임피던스도를 그려 와전류센서의 특성을 살펴보았다.

  • PDF

Performance Evaluation of Elderly Home Automation Control (EHAC) IoT System

  • Phua, Karsten Cheng Kai;Goh, Wei Wei;Marjani, Mohsen
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.1
    • /
    • pp.214-219
    • /
    • 2021
  • As the number of elderly increased rapidly every year, many elderly still choose to stay independent despite of difficulties and challenges faced in their daily routine. Elderly has desperate needs for support for their living. Internet of Things helps to support and improve elderly's life in many ways to meet the needs and requirements. Home Automation Control (EHAC) is a research based system that support elderly with controlled automation solution that control and operates various home electrical appliances based on the measurement of heart pulse rate and environment temperature. This paper works on EHAC system to evaluate the performance of the system in elderly's daily routine. This paper presented experiments conducted with approach of IoT testing and discussion on analysis of the results.

Applying Parallel Processing Technique in Parallel Circuit Testing Application for improve Circuit Test Ability in Circuit manufacturing

  • Prabhavat, Sittiporn;Nilagupta, Pradondet
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.792-793
    • /
    • 2005
  • Circuit testing process is very important in IC Manufacturing there are two ways in research for circuit testing improvement. These are ATPG Tool Design and Test simulation application. We are interested in how to use parallel technique such as one-side communication, parallel IO and dynamic Process with data partition for circuit testing improvement and we use one-side communication technique in this paper. The parallel ATPG Tool can reduce the test pattern sets of the circuit that is designed in laboratory for make sure that the fault is not occur. After that, we use result for parallel circuit test simulation to find fault between designed circuit and tested circuit. From the experiment, We use less execution time than non-parallel Process. And we can set more parameter for less test size. Previous experiment we can't do it because some parameter will affect much waste time. But in the research, if we use the best ATPG Tool can optimize to least test sets and parallel circuit testing application will not work. Because there are too little test set for circuit testing application. In this paper we use a standard sequential circuit of ISCAS89.

  • PDF

The clinical usefulness of non-invasive prenatal testing in pregnancies with abnormal ultrasound findings

  • Boo, Hyeyeon;Kim, So Yun;Seoung, Eui Sun;Kim, Min Hyung;Kim, Moon Young;Ryu, Hyun Mee;Han, You Jung;Chung, Jin Hoon
    • Journal of Genetic Medicine
    • /
    • v.15 no.2
    • /
    • pp.79-86
    • /
    • 2018
  • Purpose: This study aimed to evaluate the clinical usefulness of non-invasive prenatal testing (NIPT) as an alternative testing of invasive diagnostic testing in pregnancies with ultrasound abnormalities. Materials and Methods: This was a retrospective study of pregnant women with abnormal ultrasound findings before 24 weeks of gestation between April 2016 and March 2017. Abnormal ultrasound findings included isolated increased nuchal translucency, structural anomalies, and soft markers. The NIPT or diagnostic test was conducted and NIPT detected trisomy 21 (T21), T18, T13 and sex chromosomal abnormalities. We analyzed the false positive and residual risks of NIPT based on the ultrasound findings. Results: During the study period, 824 pregnant women had abnormal ultrasound findings. Among the study population, 139 patients (16.9%) underwent NIPT. When NIPT was solely performed in the patients with abnormal ultrasound findings, overall false positive risk was 2.2% and this study found residual risks of NIPT. However, the discordant results of NIPT differed according to the type of abnormal ultrasound findings. Discordant results were significant in the group with structural anomalies with 4.4% false positive rate. However, no discordant results were found in the group with single soft markers. Conclusion: This study found different efficacy of NIPT according to the ultrasound findings. The results emphasize the importance of individualized counseling for prenatal screening or diagnostic test based on the type of abnormal ultrasound.