• Title/Summary/Keyword: T-pipe

Search Result 397, Processing Time 0.028 seconds

Behavior of Axial Load Transfer for Open-ended Steel Pipe Pile in Alluvial Deposits (하상퇴적토층에 관입된 개단강관말뚝의 축하중 전이 거동)

  • 김상현;성인출;정창규;김명학;최용규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.283-290
    • /
    • 2001
  • In this study, static Pile load tests and PDA for open-ended steel pipe pile($\phi$ = 609.6 mm, t = 14 mm) penetrated into the gravel layer(GP - GM) was accomplished and axial load distribution was measured. Based on the tests results, the ultimate bearing capacity and axial load bearing mode were examined. Also, the ultimate pile capacity was calculated by APIL $E^{PLUS}$./.

  • PDF

Development of A Friction Type Garlic Separator (마찰식 박피마늘 선별기 개발)

  • Park, J.B.;Kim, J.T.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Both the wet and dry types of garlic peeling machines are being presently used in domestic garlic processing factory, but the dry type is more popular than the wet type because of higher peeling efficiency. The peeling efficiency of these machines is estimated 50 to 80%, depending on the difference in garlic varieties, physical properties and moisture content of garlic samples. If the peeling time is increased in order to improve the peeling efficiency, the damage on the surface of peeled garlic and the consumption of electric power are also increased. This study was carried out to solve these problems in garlic peeling operation and to obtain the optimun design factor for the friction type separator. The results are summarized as follows : 1. The average friction coefficients of peeled and unpeeled garlic samples were 0.91 and 0.51. respectively, for the acrylic plate, and 0.96 and 0.51, respectively, for the stainless plate. 2. For the inclined acrylic pipe with the pipe length 90 cm, the inclined angle $39^{\circ}$ and the pipe diameter 45-55 mm, the falling time of peeled garlic samples was 0.2 sec, faster than unpeeled garlic samples. 3. For the inclined stainless pipe with the pipe length 90 cm, the inclined angle $34^{\circ}$, $39^{\circ}$ and the pipe diameter pipe 35 mm, the falling time of peeled garlic samples was 0.7 sec, slower than that with the pipe diameter 47mm. 4. The stainless pipe with the pipe length 80~90 cm, the inclined angle $39^{\circ}{\sim}40^{\circ}$ and the pipe diameter 40~50 mm was the most suitable as the material of friction pipe. 5. Experimental garlic peeling machine is composed of garlic sample feeding device, friction stainless pipe and hopper. The peeling efficiency was 81 to 96%, and the separating capacity, 600 gr/min.

  • PDF

Frequency Characteristics of Unsteady Flow of Cylindrical Choke in a Hydraulic Pipe (유압관로에서 원통형 초크의 비정상 유동의 주파수 특성에 관한 연구)

  • Park, S.J.;Yoo, Y.T.;Wee, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.421-434
    • /
    • 1995
  • A new instantaneous flowmeter for hydraulics by means or cylindrical chokes is developed. In this method the instantaneous flowrate through chokes is predicted in real time from measurement of pressure difference on both sides of cylindrical choke. The experimental study for the flowrate of pulsating flow in a pipe is carried out to measure differential pressure drop by using a strain gauge pressure transducer with data acquisition and processing system. A pulsating flow is verified by a visualization method. In the present study, the flow characteristic variables of laminar pulsating flow are investigated analytically and experimentally in a circular pipe. Characteristic parameters of ratio of inertia term to pressure term($\phi_{t.1}$) and ratio of viscous term to pressure term($\phi_{z.1}$) are introduced to describe the flow pattern of laminar pulsating flow.

  • PDF

Application analysis of advanced sewage treatment on the separated sewer pipe (분류식 하수관거에서의 고도하수처리공법 적용성 해석)

  • Park, Soo-Jin;Ko, Jeong-Sup;Baek, Kyung-Won;Choi, Han-Kuy
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.772-777
    • /
    • 2012
  • In order to examine the tailorability of advanced sewage treatment of a separated sewer pipe, we observed the quality of leaked water in a reactor. A2C affiliation and MBR affiliation decreased by over 78% in cases of BOD, COD, and SS. SBR affiliation decreased by 79.1% in a case of T-N. Overall, the efficiency of T-N on the above affiliations was low. SS had the high efficiency in MBR affiliation. In the end, examination of water quality improvement showed that the quality was improved from 20% to 90%; hence, it is expected that this treatment can protect the water resources of the Hongcheon River and makes it easier to use the water of the river.

  • PDF

Development of Pipe-Inspection System Using Computer Vision

  • Park, Chan-ho;Lee, Byungryoung;Soonyoung Yang;Kyungkwan Ahn;Hyunog Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.99.1-99
    • /
    • 2002
  • In this paper, a computer-vision based pipe-inspection algorithm is developed. The algorithm uses the modified Hough transformation and a line-scanning approach to identify the edge line and radius of the pipe image, from which the eccentricity and dimension of the pipe-end is calculated. Line and circle detection was performed using Laplacian operator with input image which are acquired from the front and side cameras. In order to minimize the memory usage and the processing time, a clustering method with the modified Hough transformation for line detection. The dimension of inner and outer radius of pipe is calculated by proposed line-scanning method. The method scans several lines along t...

  • PDF

Community characteristics of early biofilms formed on water distribution pipe materials (수도관 재질에 형성된 초기 생물막 형성 미생물의 군집 특성)

  • Kim, Yeong-Kwan;Park, Sung-Gu;Lee, Dong-Hun;Choi, Sung-Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.767-777
    • /
    • 2012
  • Annular Biofilm Reactor (ABR) equipped with coupons of three different pipe materials (STS 304, PVC, PE) was used to generate drinking water biofilm samples. The level of assimilable organic carbon (AOC) during the sample generation period was $37.3{\mu}g/L$, and this level did not seem to be low enough to limit the formation of biofilm in this study. Terminal-restriction fragment length polymorphism (T-RFLP) analyses determined T-RF profile as early as 3 h of exposure on PVC coupons. Average surface roughness ($R_a$) measured by atomic force microscopic analyses was 125.7 nm for PVC, and this value was higher than for STS (71.6 nm) and PE (74.0 nm). However, biofilm formation was faster on STS (6 h) than on PE (12 h), which indicated that surface roughness might not be the only factor that controlled the initiation of biofilm development. Upon detection of the T-RF peaks, richness (S) and diversity indices such as Shannon (H) and Simpson (1/D) demonstrated a rather slow increase until 48 h followed by rapid increase regardless of the pipe materials. Differences of microbial community structures among the biofilm samples were determined based on the cluster analysis using Jaccard coefficients (Sj). Biofilm communities could be divided into two distinct groups according to the exposure time regardless of the pipe materials. First group contained a young (< 48 h) biofilm samples (10 out of 11) but second group contained a mature (${\geq}$ 48 h) samples (11 out of 14). Results suggested that, due to the complexity of biofilm, the targeting of the first group of cluster was crucial for optimizing the management of drinking water distribution systems and controlling microbial growth.

The Internal Finishing Characteristics of Non-ferromagnetic Pipe Polished by Magnetic Abrasive Machining(I) (자기연마법에 의한 비자성 파이프 내면의 연마특성 (I))

  • Park, W. K.;Rho, T. W.;Seo, Y. I.;Choi, H.;lee, J. C.;Cheong, S. H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.779-782
    • /
    • 2000
  • An internal finishing process by the application of magnetic abrasive machining has been developed as a new technology to obtain a fine inner surface of pipe. In this paper, the finishing process of a non-ferromagnetic pipe by a static magnetic field method is introduced and its finishing characteristics is discussed with effective factors by various experiments. From these experimental results, it is found that the proper suppling quantity of magnetic abrasives per diameter of pipe is important, and the inner surface roughness of pipe is not changed much after certain critical finishing time. As a result of this investigation the 3.2$\mu$m Rmax in inner surface roughness of stainless steel pipe is improved to 0.7$\mu$m Rmax after 6 minutes finishing.

  • PDF

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

Two-module robotic pipe inspection system with EMATs

  • Lee, Jin-Hyuk;Han, Sangchul;Ahn, Jaekyu;Kim, Dae-Hyun;Moon, Hyungpil
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.1041-1063
    • /
    • 2014
  • This work introduces a two-module robotic pipe inspection system with ultrasonic NDE device to evaluate the integrity of pipe structures. The proposed robotic platform has high mobility. The two module mobile robot platform overcomes pipe obstacle structures such as elbow, or T-branch joints by cooperative maneuvers. Also, it can climb up the straight pipeline at a fast speed due to the wheel driven mechanism. For inspection of pipe structure, SH-waves generated by EMAT are applied with additional signal processing methods. A wavelet transform is implemented to extract a meaningful and specific signal from the superposed SH-wave signals. Intensity ratio which is normalized the defect signals intensity by the maximum intensity of directly transmitted signals in the wavelet transforms spectrum is applied to evaluate defects quantitatively. It is experimentally verified that the robotic ultrasonic inspection system with EMAT is capable of non-destructive inspection and evaluation of defects in pipe structure successfully by applying signal processing method based on wavelet transform.