• Title/Summary/Keyword: T-loop

Search Result 561, Processing Time 0.026 seconds

MECHANICAL ANALYSIS OF THE PATTERN OF MOVEMENT DURING RETRACT10N OF MAXILLARY INCISORS BY SPACE CLOSING LOOP (Space closing loop에 의해 야기되는 상악 절치부 이동양상에 관한 역학적 연구)

  • Min, Sang-Hong;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.143-152
    • /
    • 1995
  • This study was performed, by Finite Element Method, to evaluate the stress distribution on the periodontal tissue according to activation of the various closing loops and to predict the pattern of movement of maxillary incisors. At the same time, bull loop, key-hole loop, T-loop, combination loop and asymmetrical T-loop which were used for retraction of maxillary incisors was analysed by Finite Element Method. The following results were obtained 1. Horizontal force was the greatest in bull loop, the followed by key-hole loop, combination loop, T-loop and initial tooth movement exhibited uncontrolled tipping. 2. Horizontal force in asymmetrical T-loop compared to other closing loops was remarkably decreased, and the intrusive force on the incisors occurred. 3. As torque was increased, the moment was increased as a linear increment. 4. As moment was increased, initial movement of tooth changed to root movement from uncontrolled tipping.

  • PDF

A FEM study about the initial stress distribution on canine altered by the application point of preangulated TMA T-loop spring (Preangulated TMA T-loop spring의 적용 위치 변화에 따른 견치의 초기 응력 분포에 대한 유한 요소법적 연구)

  • Kim, Jung-Min;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.521-534
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution on canine altered by the application point of preangulated T-loop spring. For this study, the finite element models of upper left canine, upper left second premolar and upper left first molar were made. Also, the finite element models of $0.017{\times}0.025$ inch preangulated, preactivated T-loop spring and $0.018{\times}0.025$ inch stainless steel wire were made. Three types of T-loop spring were made . the middle of activated T-loop is positioned in accordance with the middle position of distance of bracket position of both the canine and first molar, 2mm anterior, 2mm posterior. We compared the forces and the distribution of stress that were generated by the difference of position of T-loop spring. The results were as follows. 1. All of the 3 types of T-loop spring showed the similar retraction forces. 2. All showed the similar amount & pattern of stress distribution. 3. The centers of rotation of canine in 3 types of T-loop spring were same and were positioned between C and D plane. 4. The canine showed the intrusive force by 2mm anterior positioned T-loop spring, but the extrusive force by 2mm posterior positioned T-loop suing. Neverthless, because of the small amount of the forces, the effect of vertical force was not significant.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS FOR REACTION TO MOLAR UPRIGHTING SPRING (대구치 직립 스프링 적용시 반작용에 관한 삼차원 유한요소법적 연구)

  • Choe, Yoo-Kyung;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.61-74
    • /
    • 1998
  • The Purpose of this study was to investigate the stress distribution and tooth displacement at the initial phase produced by 5 types of molar uprighting springs using finite element method. The three dimensional finite element model of lower dentition, bone and springs was composed of 5083 elements and 2071 nodes. The results were as follows: 1. In case of helical spring and root spring, intrusion of lower canine and first premolar were observed md distal tipping, translation and extrusion of lower second molar were observed. 2. In case of T-loop, modified T-loop and box loop, intrusion and distal translation of lower second premolar were observed, and the largest crown distal tipping and translation of lower second molar were observed in T-loop and the smallest were observed in box loop. 3. In case of T-loop with cinch-bact crown distal tipping and translation of lower second molar were decreased, but extrusion was also decreased. 4. With increase of activation in T-loop, mesial translation and won distal tipping of lower second molar were increased and edentulous space was closing, but distal translation of second premolar was also increased. 5. With increase of tip-back bend in T--loop, distal tipping and translation of lower second molar were increased, but extrusion was also increased more largely.

  • PDF

A STUDY ON THE CHANGES OF THE ELASTIC PROPERTIES TN LOOPED WIRES BY VARIABLE FACTORS (변환요소에 따른 LOOPED WIRE의 탄성 변화에 관한 연구)

  • Na, Yong-In;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.263-271
    • /
    • 1995
  • The purpose of this study nab to evlauate and compare the effect of the variable factors of wire on the elastic properties of looped rectangular wire. Five variable factors were presented-material(Hi-T, blue Elgiloy), wire size(.016'$\;\times\;$.022', .018'$\;\times\;$.025'), loop length(15mm, 20mm), loop configuration(open loop, closed loop), gabling (non-gable, gable). So, the total 256 specimens were divided into 32 groups, and each of those nab pulled on Instron testing machine. The load-deflection curve of each wire obtained, from which force, range in elastic limit, and stiffness were computed and analyzed statistically. The results were obtained as follows : 1. All of the variable factors - wire material, size, loop length loop configuration, and gabling - took a significant effect on load-deflection rate of looped wire. 2. The force at elastic limit was the smallest in the group of Hi-T, .016'$\;\times\;$.022', 20mm loop length, open loop, non-gable, and the largest in the group of blue Elgiloy, .018'$\;\times\;$.025', 15mm loop length, closed loop, non-gable. 3. The range at elastic limit was the smallest in the group of Hi-T, .018'$\;\times\;$.025', 15mm loop length, open loop, non-gable, and the largest in the group of HI-T, .016'$\;\times\;$.022', 20mm loop length, closed loop, gable. 4. Loop configuration and loop length were the most effective factors on the elastic properties of looped wires, and gabling was the least effective.

  • PDF

A photoelastic study of the stress distribution on canine retraction by segmented TMA T-loop spring (Segmented TMA T-loop spring에 의한 견치 후방이동시의 응력분포에 관한 광탄성법적 분석)

  • Yoon, Young-Jooh;Kim, Kwang-Won;Yu, Pil-Sik
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.199-207
    • /
    • 2001
  • The segmented TMA T-loop spring, used for reciprocal space closure and described by Burstone, was used to achievebodily movement of canine. Photoelastic analysis is a technique for the transformation of internal stress into visible light patterns. The two-dimensional photoelastic stress analysis was performed, and stress distribution was recorded by photography. The purpose of this study was to visualize photoelastically the distribution of forces transmitted to the alveolus and surrounding structures using new segmented TMA T-loop spring for canine retraction. The results were as follows: 1. Decreased activation produced decreased stress of upper 1st. premolar extraction site and increased intrusive stress of upper 1st. molar, regardless of T-loop position. 2. At 5mm activation, More posterior positioning of T-loop Produced an increased stress in upper 1st. premolar extraction site. 3. At 3mm activation, More posterior positioning of T-loop produced an increased stress in upper 1st. premolar extraction site and mesial lower half of upper 1st. molar mesio-buccal root. 4. At 1mm activation, More anterior positioning of T-loop produced an increased stress in upper mesial and blew apex area of upper canine root. 5. 0.25 B/L ratio and 3mm activation produced bodily movement of canine. To summarize, desired tooth movement and anchorage requirement is possible by altering the activation and mesio-distal position of the T-loop spring.

  • PDF

The Removal of Organics, Nitrogen and Phosphorus in Loop Reactor Using Fluidized Media (유동상 담체를 이용한 Loop Reactor에서 유기물 및 질소, 인 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.353-360
    • /
    • 2009
  • This study was accomplished using Anaerobic/Anoxic/Oxic upflow packed-bed column reactors with fixed media and Loop Reactor with fluidized media instead of Oxic reactor. The objectives of this study was to investigate the characteristics of organics, nitrogen and phosphorus removal from sewage with the HRT. The average removal efficiencies of $BOD_5$ and SS increase as increasing the hydraulic retention time (HRT) until 16 h of the HRT, and they were constant over 16 h of the HRT. The removal efficiency of $BOD_5$ in case of packed-bed reactor and Loop Reactor was about 86.6% and 90.9% respectively at 16 h of the HRT. The removal efficiency of SS in packed-bed reactor and Loop Reactor was about 78.0% and 88.2% respectively at 16 h of the HRT. The average removal efficiencies of $COD_{Cr}$ and $COD_{Mn}$ showed similar trends as those of $BOD_5$ and SS. At the HRT of 16 h, the removal efficiency of $COD_{Cr}$ in case of packed-bed reactor and Loop Reactor was 63.5%, 75.2% and that of $COD_{Mn}$ was 60.7%, 73.6% respectively. The average removal efficiencies of T-N and T-P increase as increasing the HRT. The removal efficiencies of T-N and T-P in Loop Reactor were 33.6% and 54.5% respectively at 16 h of the HRT and T-N and T-P were better removed in Loop Reactor. From this result, it was found that the performance of Loop Reactor was much higher than the performance of packed-bed reactor and the optimum HRT was 16 h.

Analysis of loop duct system by extended T-method (확장 T-method에 의한 환상식 덕트시스템 해석)

  • 이승철;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF

The Mean Transit Time of the CBD and the Afferent Loop Using $^{99m}Tc-DISIDA$ Scintigram in Truncal Vagotomy (미주신경간절제술에 있어서 $^{99m}Tc-DISIDA$ 신티그램을 이용한 총수담관 및 Afferent loop의 평균지연시간)

  • Moon, Tae-Yong;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.2
    • /
    • pp.199-203
    • /
    • 1988
  • The authors observed functional change of the CBD and the afferent loop with the transit time of $^{99m}Tc-DISIDA$ scintigram in patients treated by the surgical operation of gastric ulcers and cancer at Busan National University Hospital from June, 1987 to April, 1988. So authors estimated the time between the peak activity of the CBD and the afferent loop (TCA), the half transit time of the CBD activity (t 1/2 CBD) and the half transit time of the afferent loop activity (t 1/2 A-loop) in 9 patients undergone truncal vagotomy, who have no specific symptoms at 2 to 6 months after the operation, 5 patients undergone the operation without truncal vagotomy, and 7 persons as a control group. The results were as follows: I) In control group, the mean TCA, t 1/2 CBD and t 1/2 duodenum were $8.6{\pm}9.0$ min, $38.7{\pm}17.3$ min. and $28.6{\pm}10.9$ min, respectively. 2) In the operation group without truncal vagotomy, the mean TCA, t 1/2 CBD and t 1/2 A-loop were $10.0{\pm}7.1$ min. $48.2{\pm}22.3$ min. and $39.4{\pm}26.7$ min. respectively. 3) In the operation group with truncal vagotomy, the mean TCA, t 1/2 CBD and t 1/2 A-loop were $15.0{\pm}8.7$ min., $36.1{\pm}16.5$ min. and $42.6{\pm}24.4$ min, respectively. From the above results, we concluded that the transit time of the CBD and the afferent loop is not affected by truncal vagotomy.

  • PDF

Critical Adjuvant Influences on Preventive Anti-Metastasis Vaccine Using a Structural Epitope Derived from Membrane Type Protease PRSS14

  • Ki Yeon Kim;Eun Hye Cho;Minsang Yoon;Moon Gyo Kim
    • IMMUNE NETWORK
    • /
    • v.20 no.4
    • /
    • pp.33.1-33.19
    • /
    • 2020
  • We tested how adjuvants effect in a cancer vaccine model using an epitope derived from an autoactivation loop of membrane-type protease serine protease 14 (PRSS14; loop metavaccine) in mouse mammary tumor virus (MMTV)-polyoma middle tumor-antigen (PyMT) system and in 2 other orthotopic mouse systems. Earlier, we reported that loop metavaccine effectively prevented progression and metastasis regardless of adjuvant types and TH types of hosts in tail-vein injection systems. However, the loop metavaccine with Freund's complete adjuvant (CFA) reduced cancer progression and metastasis while that with alum, to our surprise, were adversely affected in 3 tumor bearing mouse models. The amounts of loop peptide specific antibodies inversely correlated with tumor burden and metastasis, meanwhile both TH1 and TH2 isotypes were present regardless of host type and adjuvant. Tumor infiltrating myeloid cells such as eosinophil, monocyte, and neutrophil were asymmetrically distributed among 2 adjuvant groups with loop metavaccine. Systemic expression profiling using the lymph nodes of the differentially immunized MMTV-PyMT mouse revealed that adjuvant types, as well as loop metavaccine can change the immune signatures. Specifically, loop metavaccine itself induces TH2 and TH17 responses but reduces TH1 and Treg responses regardless of adjuvant type, whereas CFA but not alum increased follicular TH response. Among the myeloid signatures, eosinophil was most distinct between CFA and alum. Survival analysis of breast cancer patients showed that eosinophil chemokines can be useful prognostic factors in PRSS14 positive patients. Based on these observations, we concluded that multiple immune parameters are to be considered when applying a vaccine strategy to cancer patients.

Microstrip Bandpass Filter Using of a T-Shaped Meander Loop Resonator (Microstrip Bandpass Filter을 이용한 향상된 T-Shaped Meander Loop 공진기)

  • 정주현;오인열;나극환
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.157-160
    • /
    • 2001
  • 본 논문에서 5.8GHz의 주파수 대역에서 사용할 수 있는 향상된 커플링 구조와 크기를 줄인 dual-mode microstrip bandpass filter를 설계하였다. 여기서 meander loop resonator를 쓰는 이유는 크기가 작고 방사 손실이 적으며 패턴이 간단하기 때문이다. 또한 이와 비슷한 특성을 갖는 ring, square patch, disk등은 불연속 성분을 가짐으로써 이중모드의 구현이 가능하다. 향상된 형태의 dual-mode microstrip bandpass filter의 변형된 T-shaped meander loop resonator를 소형으로 발전되고. 높은 선택도를 가지는 구조이다. 이 형태의 filter에서 150MHz의 bandwidth을 가지고 5.8GHz주파수를 가지는 구조로 설계하였다.

  • PDF