• 제목/요약/키워드: T-Scan

Search Result 611, Processing Time 0.031 seconds

$^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant (개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔)

  • Zeon, S.K.;Ryu, J.G.;Park, C.K.;Yoo, Y.S.;Jung, D.S.;Lee, J.K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

UDP-Based Active Scan for IoT Security (UAIS)

  • Jung, Hyun-Chul;Jo, Hyun-geun;Lee, Heejo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.1
    • /
    • pp.20-34
    • /
    • 2021
  • Today, IoT devices are flooding, and traffic is increasing rapidly. The Internet of Things creates a variety of added value through connections between devices, while many devices are easily targeted by attackers due to security vulnerabilities. In the IoT environment, security diagnosis has problems such as having to provide different solutions for different types of devices in network situations where various types of devices are interlocked, personal leakage of security solutions themselves, and high cost, etc. To avoid such problems, a TCP-based active scan was presented. However, the TCP-based active scan has limitations that it is difficult to be applied to real-time systems due to long detection times. To complement this, this study uses UDP-based approaches. Specifically, a lightweight active scan algorithm that effectively identifies devices using UPnP protocols (SSDP, MDNS, and MBNS) that are most commonly used by manufacturers is proposed. The experimental results of this study have shown that devices can be distinguished by more than twice the true positive and recall at an average time of 1524 times faster than Nmap, which has a firm position in the field.

Efficient Test Data Compression and Low Power Scan Testing for System-On-a-Chip(SOC) (SOC(System-On-a-Chip)에 있어서 효율적인 테스트 데이터 압축 및 저전력 스캔 테스트)

  • Park Byoung-Soo;Jung Jun-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.229-236
    • /
    • 2005
  • Testing time and power consumption during testing System-On-a-Chip (SOC) are becoming increasingly important as the IP core increases in a SOC. We present a new algorithm to reduce the scan-in power and test data volume using the modified scan latch reordering. We apply scan latch reordering technique for minimizing the hamming distance in scan vectors. Also, during scan latch reordering, the don't care inputs in scan vectors are assigned for low power and high compression. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases.

  • PDF

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

Low Power Scan Testing and Test Data Compression for System-On-a-Chip (System-On-a-Chip(SOC)에 대한 효율적인 테스트 데이터 압축 및 저전력 스캔 테스트)

  • 정준모;정정화
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.12
    • /
    • pp.1045-1054
    • /
    • 2002
  • We present a new low power scan testing and test data compression mothod lot System-On-a-Chip (SOC). The don't cares in unspecified scan vectors are mapped to binary values for low Power and encoded by adaptive encoding method for higher compression. Also, the scan-in direction of scan vectors is determined for low power. Experimental results for full - scanned versions of ISCAS 89 benchmark circuits show that the proposed method has both low power and higher compression.

Low Power Test for SoC(System-On-Chip)

  • Jung, Jun-Mo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.892-895
    • /
    • 2011
  • Power consumption during testing System-On-Chip (SOC) are becoming increasingly important as the IP core increases in SOC. We present a new algorithm to reduce the scan-in power using the modified scan latch reordering and clock gating. We apply scan latch reordering technique for minimizing the hamming distance in scan vectors. Also, during scan latch reordering, the don't care inputs in scan vectors are assigned for low power. Also, we apply the clock gated scan cells. Experimental results for ISCAS 89 benchmark circuits show that reduced low power scan testing can be achieved in all cases.

  • PDF

The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time (스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구)

  • Lee, Jong-Hun;Ryu, Jae-Kwang;Chung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The examination of nuclear medicine observes the change in accordance with the time elapsed in the same region purposed and there are many examinations to acquire the image during the same term. At this time, the same parameter should be applied. The hepatobiliary scan, lung scan etc, are the acquired examination in the divided time with a regular term. Pre-set time that is applied in continued next image is set in order to acquire the fixed counts. The same scan time should be applied for each image. This study will look for the rational plan and analyze the change of scan time in accordance with the time of the decision of scan time at examination that pre-set time is applied. Methods: The hapatobiliary scan that use the radio pharmaceutical $^{99m}Tc$-mebrofenin is choosed as compensation from Jan. 2009 to Mar. 2009 in the department of nuclear medicine in ASAN MEDICAL CENTER. Scan is started after 5 minutes from when 222 MBq (6 mCi) is injected to patient. We let patient stand up between both detectors, and possibly close to the front of detector. When scan time reach 10%, 25%, 50%, 75% of total scan time, we measured the expected total scan time. After finishing all of scan, we compared the total scan time and the expected total scan time, while image is acquiring. and we observed the change of scan time in accordance with radio activity by using phantom. Results: After starting scan, a difference of when scan time reach 10%, 25%, 50%, 75% of total scan time is that the biggest difference is 5 seconds on 10%. There statistically is difference between 25% (t:2.88, p<0.01) and 50% (t:2.05, p<0.01). Conclusions: When the same the scan time is applied in the examination that acquire the many frame, concluding the same scan time has a important effect on a quantitative analysis. Although method that decide the scan time after finish all of the examinations, there is a few problem to apply practical affairs. This may cause an inaccurate result on the examination that need a quantitative analysis. We think that operator should try to improve it. At least, after reach 50% of total scan time, deciding the total scan time mean that you can minimize error of a quantitative analysis caused by unmatched scan time from a gap of image.

  • PDF

A review on the development of a scan statistic and its applications (스캔 통계량의 발전 과정과 응용에 대한 고찰)

  • 김병수;김기한
    • The Korean Journal of Applied Statistics
    • /
    • v.6 no.1
    • /
    • pp.125-143
    • /
    • 1993
  • The primary objective of the paper is to review the development of approximations of the null distribution of a scan statistic and to show how these approximations were improved. Let $X_1, \cdots, X_N$ be a sequence of independent uniform random variables on an interval (0, t]. A can statistic is defined to be the maximum number of observations in a subinterval of length t $\leq$ T, when we continuously (or discretely) move the subinterval from 0 to T. A scan statistic is used to test whether certain events occur in a cluster aganist a null hypothesis of the uniformity. It is difficult to calculate the exact null distribution of a scan statistic. Several authors have suggested approximations of the null distribution of a scan statistic since Naus(1966). We conceive that a scan statistic can be used for detecting a "hot region" is defined to be a region at which the frequencies of mutations are relatively high. A "hot region" may be regarded as a generalized version of a hot spot. We leave it for a further study the concrete formulation of deteciton a "hot region" in a mutational spectrum.uot; in a mutational spectrum.

  • PDF

Feedback on Baseline Use of Staging Images is Important to Improve Image Overuse with Newly Diagnosed Prostate Cancer Patients

  • Sawazaki, Harutake;Sengiku, Atsushi;Imamura, Masaaki;Takahashi, Takeshi;Kobayashi, Hisato;Ogura, Keiji
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1707-1710
    • /
    • 2014
  • Background: The objective of this study was to evaluate baseline use and positive rates of staging images (bone scan, CT) in newly diagnosed patients with prostate cancer (PCa) and to improve staging image overuse. Materials and Methods: This retrospective study covered a consecutive series of patients with PCa who underwent stage imaging at our institution between 2006 and 2011. Various clinical and pathological variables (age, PSA, biopsy Gleason score, clinical T stage, positive biopsy core rate) were evaluated by multivariate logistic regression analysis for their ability to predict a positive staging image. All patients were stratified according to the NCCN risk stratification and positive rates were compared in each risk group. Results: 410 patients (100%) underwent a bone scan and 315 patients (76.8%) underwent a CT scan. Some 51 patients (12.4%) had a positive bone scan, clinical T3 and T4 being significant independent predictors. Positive bone scan rates for low-, intermediate-, high-, and very high-risk groups were 0%, 0%, 8.25%, and 56.6%. Some 59 (18.7%) patients had a positive CT scan, with elevated PSA and clinical T3, T4 as significant independent predictors. Low-, intermediate-, high- and very high-risk group rates were 0%, 0%, 13.8% and 80.0%. Conclusions: The incidences of positive staging image in low- and intermediate- risk group were reasonably low. Following feedback on these results, staging in low- and intermediate- risk groups could be omitted.

Study of Disclusion Time during Mandibular Eccentric Movement in Myofascial Pain Syndrome Patients by T-Scan II, Computerized Occlusal Analysis System (컴퓨터 교학분석기인 T-Scan II를 이용한 측방운동시 구치부 이개시간에 관한 연구)

  • Shin, Jun-Han;Kwon, Jeong-Seung;Kim, Seong-Taek;Park, Hyung-Uk;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.187-197
    • /
    • 2011
  • Temporomandibular disorders(TMD) is a collective term which is embracing a number of clinical problems that involve the masticatory musculature, the TMJ and associated structures, or both. Myofascial pain, which is a kind of masticatory muscle disorder of TMD, is the sensory, motor, and autonomic symptoms caused by myofascial trigger points. There has been some controversies regarding etiologies of TMD and MFP. Especially the issue of occlusal conditions has been a critical issue for long time. Despite much efforts, the results of studies regarding occlusal conditions were contradictory. These controversies might be mostly due to various factors resulting from the complex nature of TMD, however, inaccurate and inappropriate study design, selection criteria, methodologies also play significant roles. Recently, a computerized occlusal analysis system, T-Scan II which made it possible to reveal quantifiable time data and relative force data for analyzing occlusion, was introduced. Some authorities suggested that the concept of disclusion time and prolonged disclusion time of posterior tooth and MFP are related using T-Scan II. But the previous studies which used T-SCAN II are not reliable for they did not provide accurate diagnostic criteria of MFP. Morever they did not compare with controls, and had many other problems. The purpose of this study was to evaluate the relationship between MFP and prolonged disclusion time of posterior tooth, which is one of the occlusal factors of TMD, by selecting 30 subjects as the study group through strict criteria and comparing them with 38 controls using T-SCAN II, computerized occlusal analysis system. The results, statistically analyzed, are summarized as follows: 1. Cronbach ${\alpha}$ coefficient of repeated measurements of disclusion time was 0.92. 2. There were no statistically significant differences at repeated measured disclusion time of both side between control and study group. 3. There was no statistically significant diffefence in the disclusion time between right and left side. From the results above, we can suggest that there was no relationship between MFP and disclusion time, so irreversible treatments leading to the reduction of disclusion time for treating MFP would not be appropriate. However more controlled, large scaled study, which consider various occlusal factors, and quantification of symptoms using Helkimo index would be necessary in the future.