Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration (RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1733-1738
    • /
    • 2008
  • The treatment efficiency of rotating biological contactors (RBCs) for the high strength of dairy wastewater was investigated. Two different systems were conducted composing of a single RBC with tapered aeration reactors for the system A and a sequential RBCs following tapered aeration reactors for the system B. Experiments using dairy wastewater were conducted for 50 days period of time, in which hydraulic rates were maintained at the constant ratios of 346L per day and variable BOD concentrations were at the range from 1,358mg/L to 829mg/L, the $COD_{cr}$, concentration of the range were from 2,384mg/L to 1,329mg/L, the range of T-N concentrations was from 66mg/L to 38mg/L, and 50% of internal recycle and 50% of sludge return were performed. Results indicated that the removal efficiencies of the system B were higher than those of the system A. The removal efficiencies of system A for the BOD, $COD_{cr}$, T-N and T-P were 97.8%, 96.7%, 87.2% and 82%, respectively. The removal efficiencies of system B for the BOD, $COD_{cr}$, T-N and T-P were as of 98.5%, 98.5%, 91.3% and 89%.

Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum (Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

Removal Character of Nitrogen and Phosphorus in Swine Wastewater with Injection Time of Acetic Acid on SBR (SBR에서 아세트산 주입시간변화에 따른 양돈폐수의 질소, 인 제거특성)

  • Huh, Mock;Lee, Yong-Doo;Kang, Jin-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.1
    • /
    • pp.132-137
    • /
    • 2003
  • This study was carried out to investigate removal character of nitrogen and phosphorus with injection time of acetic acid on SBR, which is one of the biological treatment process. Wastewater used in experiment period was swine wastewater with character, relatively lower organic material concentration than nitrogen concentration. In the experiment with injection time of acetic acid, run 1 wasn't injected acetic acid during the anoxic period, and run 2 was injected intermittently acetic acid during the anoxic period of 15 hours. And run 3 was injected intermittently during the anoxic period of 3hours from end of wastewater filling. And filing time of the wastewater was 20hour from run 1 to run 3. In the study, the highest removal efficiency of organic and nitrogen were obtained by the operating condition of Run 2(the ratio of mixing/aeration time : 16.5/5.5, injection time of acetic acid : 15hours) and T-P was obtained by the operation condition of Run 3(the ratio of mixing/aeration time : 16.5/5.5, injection time of acetic acid : 3hours),and removal efficiency of $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, T-N and T-P in the treated water was 96.1%, 87.7%, 90.6%, 86.6% and 84.5%, respectively.

  • PDF

Optimum Design of Animal Wastewater Treatment System (畜産廢水處理시스템의 最適說計要因 導出)

  • Oh, In-Hwan;Park, Joeng-Hyun;Kim, Beom-Seok;Lee, Sang-Rak;Maeng, Won-Jae
    • Journal of Animal Environmental Science
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1995
  • An efficient Treatment of animal wastewater is one of the hot issues for preventing the environmental pollution. It should be established the design parameter in order to purify the animal wastewater. A test is carried on in the pilot plant as a simplified activated sludge process. A vibration sieve separator is deviced to keep the pollution load constant by means of separation of solid matter. The BOD removal efficiency of the vibration sieve showed over 50%. As the test results, the BOD contents of the influent was in average of 3,000 mg/I and that of the effluent 85 mg/I. So, the BOD removal rate showed 97% in average. The SS-contents in the primary chamber was about 3,300 mg/I and that of effluent 92 mg/I. The SS removal efficiency showed 97%. The removal rate of total nitrogen and phosphore were in average of 82% respectively. Carrying out in winter season, it showed relatively good results; The design parameter approved in this test can be applied to the full-time farmers.

  • PDF

Development of New BNR Process Using Fixed-Biofilm to Retrofit the Existing Sewage Treatment Plant (고정생물막을 이용한 기존 하수처리장의 생물학적 영양염 제커 신공정개발)

  • Kim, Mi-Hwa;Lee, Ji-Hyung;Chun, Yang-Kun;Park, Tae-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1093-1101
    • /
    • 2000
  • The object of this study was to develop new BNR process using fixed-biofilm which could be applied to retrofit the existing wastewater treatment plant or to introduce as tertiary treatment plant. To achieve complete denitrification from typical raw sewage in Korea, external carbon source must be supplied because $SCOD_{cr}/T-N(NH_4{^+}-N+NOx-N)$of raw sewage was lower than other countries. In this study, the ratio of $SCOD_{cr}/NH_4{^+}-N$ was 2.49 and the influent $NH_4{^+}$-N concentration during the experimental period was varied from 25 to 37 mg/L. To enhance nitrogen removal from the sewage, the two processes using fixed biofilm were adopted as R-Hanoxic/mid.settler/aerobic/anoxic/ aerobic) and R-2(aerobic/mid.settlerlanoxic/anoxic/aerobic), respectively. In the comparison of $NH_4{^+}$-N, T-N effluent quality and T-N removal efficiency in both processes without external carbon source, R-1 process was better than R-2 process for nitrogen removal from raw sewage. With respect to $SCOD_{cr}$/NOx-N ratio and total nitrogen removal in each anoxic reactor of two processes, R-1's was more effective than R-2's for distributing organic matters of raw sewage. In the both processes using fixed biofilm, the amount of required alkalinity to remove unit $NH_4{^+}$-N were 5.18 and 5.76($g{\cdot}CaCO_3/g{\cdot}NH_4{^+}-N_{removed}$), respectively and were lower than activated sludge BNR process(7.14).

  • PDF

Characteristics of Wastewater Treatment in Applying RBC Modified Dephanox Process (회전원판법을 적용한 Modified Dephanox 공정의 하수처리특성)

  • Kang, Min-Koo;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.477-486
    • /
    • 2010
  • This study was performed with the object in which it improves the nitrification by using RBC, that is one of the biological waste water treatment process. By applying the Modified Dephanox process to RBC in this research in order to evaluate the improvement of the nitrification by RBC a research was conducted. There is the most conspicuous feature of the process of using RBC. it is that the nitrification can be smoothly performed even if the suspended solid of the high concentration as the interference factor in the nitrification tank is flowed in. Moreover, as a result of experiment, TCOD removal efficiency of the process showed up more than about 90%. when influent TCOD loading rate was 0.04~0.1 kg / $day{\cdot}m^3$. and T-N removal efficiency is high at about 75% in spite of the process operating of the laboratory scale was observed. Also, As increasing influent ${PO_4}^{3-}$-P, T-P loading rate, ${PO_4}^{3-}$-P, T-P removal efficiency was increased. Finally, it was elucidated that the utilization of RBC in external nitrification system resulted in not only high nitrification performance but also stable system operation by minimizing inhibitory effect of overflowed suspended solid (SS).

Evaluation of Pollutant Removal Efficiency through Field Test-Bed Experiment in the Rural Small Stream (저수지 유입하천 현장적용실험을 통한 수질정화효율 평가)

  • Choi, Sun Hwa;Oh, Jong Min;Kim, Tae-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.12
    • /
    • pp.1135-1143
    • /
    • 2014
  • This study was carry out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat (FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow, and we conducted a experiment on the water treatment process using the aquatic plants such as Eichhornia crassipes. The removal efficiencies (%) of water quality parameters were SS 80.9%, COD 74.6%, TN 76.8%, TP 84.4%, DTN 93.8% and DTP 98.3%, respectively. Temperature, a effect factor, was $21.8{\pm}5.9^{\circ}C$ during the operating period, according to temperature had no effect on the removal efficiencies of pollutants. Hydraulic retention time (HRT) strongly correlated with removal efficiencies (%) of SS and TP having r=0.414 (p<0.005), r=0.446 (p<0.005), respectively, and when HRT was 5day had highly removal efficiency (%) in SS and TP. TN and TP removal efficiency increased with ratio decreasing in both COD/TN and COD/TP of Influent.

Phosphorus Removal from Domestic Sewage by Electrolysis with Aluminium Electrodes (알루미늄의 전기분해를 이용한 오수 중의 인 제거)

  • Cheong, Kyung-Hoon;Choi, Hyung-Il;Jung, Oh-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.70-76
    • /
    • 1999
  • A laboratory experiment was performed to investigate the phosphorus removal using the activated sludge-electrolysis reactor which consisted of A$^2$/O system and aluminium electrodes as cathode and anode. In this system, the phosphorus was removed by aluminium ion, which was eluted from aluminiumelectrodes by electrolysis. In the batch experiments, when the current densities were 0.026, 0.052 and 0.08 A/dm$^2$, the phosphorus removal efficiencies for synthetic sewage were 66.4, 86.4 and 98.7% respectively. These results showed that the phosphorus removal efficiency increased with the increase of the current density. When the current values were 13, 26 and 40 mA respectively, the amounts of Al$^{3+}$ eluted from electrodes according to Faraday's law were 0.049, 0.07 and 0.12 g and Al/P mole ratio were 1.1, 2.0 and 3.41. In the continuous experiments, As hydraulic retention time(HRT) increased, COD and total nitrogen(T-N) removal efficiencies for domestic sewage increased. The average phosphorus removal rates of the activated sludge-electrolysis system were 97, 91, 80 and 80% at the HRT of 48, 24, 18 and 12 hours, respectively. Especially, the phosphorus removal rate in the activated sludge system with aluminium electrodes was higher than that in the system without aluminium electrodes.

  • PDF

Study of Sewage Treatment using Multi-soil-layering System (다단토양층을 이용한 하수처리에 관한 연구)

  • Son, Dae-Hee;Chung, Yun-Chul;Shin, Jeong-Hoon;Jung, Jin-Young;Ahn, Dae-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.215-222
    • /
    • 2004
  • The sewages produced from small villages, rural community, drinking water reservation area and park which doesn't have sewage piping system can be caused a serious water pollution at the restricted areas. The objective of this research was to suggest an economical and effective sewage treatment method by investigating the removal of the organics, nitrogen, and phosphorus in the multi-soil-layering reactor. Soil, natural zeolite, and iron slag were used as a supporting media of multi-soil-layering in this research. The purpose of natural zeolite addition was to maintain the consistent ammonium exchange capacity by providing a sequential environment, and that of iron slag addition was to remove phosphorus by adsorption. Continuous experiment of lab-scale single-soil-layering (S-1), multi-soil-layering (S-2), and mixed-soil-layering (S-3) methods were studied to compare and optimize three different types of the reactors. The organic removal efficiencies showed more than 90% in all three reactors. While S-1 and S-3 reactors showed about T-N removal of 31%, 45%, respectively, the average T-N removal efficiency of the S-2 reactor represented an 87%. In conclusion, that results suggest that the multi-soil-layering reactor could be effectively utilized as a plant for treatment of small village sewage.

Phosphate Adsorption Characteristics of a Filter Medium, Adphos, and Its Efficiency by the Filtration Experiment Combined with the Vegetation Mat (Adphos 여재의 인 흡착특성과 식생 매트와 결합한 여과실험에 의한 효율)

  • Kim, Ji Ah;Joo, Gwang Jin;Choi, I Song;Chang, Kwang Hyeon;Oh, Jong Min
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.231-237
    • /
    • 2016
  • The purpose of this study is to analyze phosphate adsorption characteristic of the filter media applied in water purification technology. And it is also to observe the removal efficiency of the technology that was developed by combining the purification abilities of filter media and the vegetation mat. The filter media, Adphos, is the subject of this study. The result of adsorption test shows that $PO_4{^{3-}-P}$ adsorption characteristics of Adphos is determined by the Langmuir isotherm model fitting and the $q_m$ (maximum adsorption amount) value is calculated as 1.162 mg/g. To verify the removal efficiency of the purification technology, a lab-scale reactor, including a 400 mm depth of filter bed filled by Adphos, was manufactured. Yellow flag Iris (Iris pseudacours L.) was planted on the vegetation bed and the coir-roll was used to fix the root of vegetation. The reactor ran 8 hours per day over 71 days, and the results of filtration experiment show that average removal efficiency of SS, T-N and T-P were calculated as 94%, 41% and 64% respectively. With these results, it was proved that the purification technology is highly effective. And for the long-time use, a maintenance guide is also required.