• Title/Summary/Keyword: T-N removal efficiency

Search Result 326, Processing Time 0.029 seconds

Effect of Temperature on Removals of Organic Matter, Nitrogen and Phosphorus in MLE and M-Dephanox Processes (온도가 MLE 및 M-Dephanox 공정의 유기물, 질소 및 인 제거 효율에 미치는 영향)

  • Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • The present study evaluated effect of temperature on removals of organic matter (C), nitrogen (N) and phosphorus (P) in Modified-Dephanox (M-Dephanox) process, which is hybrid system, comparing with those of Modified-Ludzack Ettinger (MLE) under the suspended-growth bacteria, as control. M-Dephanox process was more stable than MLE process in the removal of C, N, P, especially in nitrification, as the temperature was decreased from $25^{\circ}C$ to $16^{\circ}C$. As the temperature was decreased from $25^{\circ}C$ to $16^{\circ}C$, the removal efficiency of $NH_4{^+}-N$ of M-Dephanox process was decreased by 3.8%, but that of MLE process decreased by 25.7%. T-N removal efficiency of M-Dephanox was higher than MLE process by 27.1% and 26.9% at $25^{\circ}C$ and $16^{\circ}C$ of temperature, respectively.

A study on development of basic natural system for polluted streams using wasted concrete and Oenanthe javanica (미나리와 폐콘크리트를 이용한 하천정화공법의 기초 연구)

  • Kim, Jwa-Kwan;Yoon, Sung-Yoon
    • Journal of Wetlands Research
    • /
    • v.2 no.1
    • /
    • pp.59-67
    • /
    • 2000
  • The aim of this study is to identify the role of this natural treatment system, which consists of Oenanthe javanica and wasted concrete as bio-media. Therefore, it was designed to experiment water quality, BOD, SS, T-N, T-P to recognize the efficiency of treatment system with one biofilter tank using wasted concrete and vegetation bed using Oenanthe javanica. It was also designed to compare two different biofilter reactors, which are air lift and upflow methods. In the result, it was demonstrated that upflow method is more efficient system to control water quality of polluted streams. The vegetation bed using Oenanthe javanica has the treatment efficiency of 41 % (BOD), 52 % (COD), 60% (SS), 36 % (T-P), 70 % ($NH_4-N$). It was therefore proved that removal rates of nutrients are not so good except $NH_4-N$ concentration with nitrification.

  • PDF

Analysis of Field Experimental Data for Water Quality Improvement of Tributary Stream to Estuarine Reservoir Using Constructed Wetland System (인공습지를 이용한 하구담수호 유입하천수 수질개선 현장실험결과 분석)

  • Ham, Jong-Hwa;Yoon, Chun-G.;Koo, Won-Seok;Kim, Hyung-Chul;Shin, Hyun-Bhum
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.141-153
    • /
    • 2004
  • Wetland system is widely accepted as one of natural water purification systems around the world for nonpoint sources pollution control. Constructed wetlands have become a popular technology for treating contaminated surface and waste water. In this study, the field experiment to reduce nonpoint source pollution loadings from polluted stream waters using wetland system was performed from June 2002 to March 2004. Four wetlands were used and the size of each one was 0.8ha. Water of Dangjin stream flowing into Seokmun estuarine reservoir was pumped into wetlands. Inflow and hydraulic residence time of the system was 500 $m^3$/day∼1,500 $m^3$/day, 2∼5 days, respectively. After 2 year operation, plant-coverage of the wetlauds was about 70% from bare soil surface at initial stage . Average water quality of the influent was $BOD_5$ 4.17 mg/L, TSS 18.45 mg/L, T-N 4.32 mg/L, and T-P 0.30 mg/L. The average removal rate of $BOD_5$, TSS, T-N and T-P during the study period was 5.6%, 46.6%, 45.7%, and 54.8%, respectively. Organic ($BOD_5$) removal rate was low and the reason might be low influent concentration. Wetland removal rate of T-P was about 10% higher than T-N. Performance of the experimental system was compared with existing data base (NADB), and it was within the range of general system performance. Overall, the wetland system was found to be adequate for treating polluted water stream with stable removal efficiency even during the winter period. Most of the nonpoint source pollutions from watershed are transported by streams or ditches, and they could be controled by constructed wetland system before entering the lake or reservoir.

A Study on the Removal of Nitrogen and Phosphorus by Addition of Coagulant in the Sulfur Denitrification Process Coupled to the Membrane Bioreactor (MBR과 황탈질 공정에서 응집제 주입에 따른 질소.인 제거에 관한 연구)

  • Lee, Young-Ho;Yoo, Soung-Jong;Oh, Dae-Min;Lee, Young-Sin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.949-956
    • /
    • 2010
  • A method for simultaneous removal of nitrogen and phosphate from sewage by elemental sulfur denitrification with membrane bioreactor was proposed, and capacity $10\;m^3$/day of pilot plant was operated for 350 days. This study was investigated to have the effect of denitrification rate and T-P removal with the addition of Alum in Sulfur denitrification Reactor (SDR). The addition of Alum and alkalinity ($NaHCO_3$) in the effluent of MBR was tried to remove simultaneous phosphate and nitrogen in SDR. Characteristics of total nitrogen (T-N) and total phosphate (T-P) removal was compared without and with the addition of Alum as a coagulant. T-N removal without and with the addition of Alum was 92.1% and 87.8%, respectively. And denitrification efficiency was 93.8% and 87.1%, respectively. T-P removal rate was increased to 75.6% in SDR by addition of Alum (2.6~4 mg/L as Al), but T-P removal rate was about 26.7% without the addition of Alum. Therefore, denitrification rate was 6.7% of reduction but T-P removal rate was increased by addition of Alum.

Research on Improvement of Lake Water Quality Using Artificial Floating Island (호소 수질 개선을 위한 인공식물섬 장치 개발 연구)

  • Kim, Tae-Hoon;Ahn, Tae-Woong;Jung, Jae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.263-270
    • /
    • 2010
  • This is a research on development of water purification equipment called artificial floating island (=AFI) for the stagnant water area which can secure exuberant landscape and water-friendility. The equipment devised in this study is designed to make up the weakness of conventional AFIs and improves the removal efficiency of pollutants using the mixture of media and plants. The air compressor positioned at the inlet releases air with inflow continuously, the water pump at the outlet sprays as a form of fountain with causing a disturbance on stable water column, then, both of them contribute improvement of water quality over a large area. We applied Bio-stone as a media in this system and performed an experiment of pre-efficiency test, and we concluded that the higher pollutants concentration of inflow, the higher removal efficiency we obtained. At the result of lab-scale experiment, in the case of high-concentration inflow, in the removal efficiency of SS is 62.2%, BOD is 50.2%, COD is 55.1%, T-N is 31.6%, T-P is 38.4%. In addition, to evaluate the field application, we set up the facilities in Sin-gal lake located in Yongin-Si Gyeonggi-Do, and researched on the removal efficiency of outflow relative to the inflow. As a result, SS is 53.5%, BOD is 32.8%, COD is 36.9%, T-N is 22.6%, T-N is 33.2%.

Treatment of Artificial Sewage Using a Zeolite Column (제올라이트 칼럼에 의한 인공생활하수처리)

  • Seo, Jeoung-Yoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.178-188
    • /
    • 2002
  • Constructed wetlands typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. Removal efficiency was $COD_{Cr}$ 94.63% T-P 41.41% and $NH_4^+-N$ 99.75% at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of zeolites in the diameter range of 0.5 to 1 mm and 1 to 3 mm. Accordingly, hydraulic load 314 $L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixtures were used to determine the optimal mixing ratio by volume of a zeolite (A) in the diameter range of 0.5 to 1 mm to a zeolite (B) in the diameter range of 1 to 3 mm 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm $COD_{Cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. That of T-P ranged 56.42 to 58.72% and, that of T-N and $NH_4^+-N$ was 87% and 99% regardless of mixing ratios of two zeolites. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at Inter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate far Inter medium of constructed wetland Removal efficiency was higher in down-flow than in up-flow, and all contaminants were removed most in 20 cm filter height near feeding area.

Removal of COD and T-N caused by ETA from Nuclear Power Plant Wastewater using 3D Packed Bed Bipolar Electrode System (3D 복극충진전기분해를 이용한 원전 ETA에 의해 유발된 폐수 내 COD 및 T-N 제거)

  • Kim, Han-Ki;Jeong, Joo-Young;Shin, Ja-Won;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.409-421
    • /
    • 2012
  • Ethanolamine (ETA) is mainly used to prevent corrosion of pipe in secondary cooling system of nuclear power plant. Condensed ETA in wastewater could increase COD and T-N when it was emitted to natural water system. Compared to conventional treatments, electrochemical oxidation process using packed bed bipolar electrodes was adopted to treat COD and T-N. According to arrangement of feeder electrode, single packed bed bipolar electrode reactor and multi-paired packed bed bipolar reactor were developed and conventional zero-valent iron (ZVI) was selected as conducting bipolar electrode. Bipolar electrodes were coordinated three-dimensionally in the reactor. The experimental results showed that COD and T-N was little removed in unit system at different pH condition (pH 8 and 11) on 100V. However, in multi-paired system that applied 600V, COD was eliminated 80.85% (anode-cathode-anode, A-C-A) and 85.11% (cathode-anode-cathode, C-A-C), respectively. T-N was also removed 96.88% (A-C-A) and 90.63% (C-A-C), simultaneously. Current efficiency was estimated both single and multi-paired system. At unit bipolar packed bed reactor, current efficiency was almost zero, however in multi-paired system, current efficiency was 300~500% at A-C-A and 250~350% at C-A-C. Current efficiency was over 100% hence it was confirmed that this system is more effective than conventional electrochemical oxidation system.

Treatment Kinetics of Wastewater and Morphological Characteristics of Biofilm in Upflow Biobead® Process (상향류식 바이오비드 공법을 이용한 오·폐수 처리특성 및 부착 생물막의 형태적 특징)

  • Yum, Kyu-Jin;Lee, Jeong-Hun;Kim, Sun-Mi;Choi, Weon-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.201-212
    • /
    • 2002
  • The objective of this study was to investigate the treatment efficiency, kinetics, and morphological characteristics of biofilm in upflow $Biobead^{(R)}$ process, a kind of biological aerated filter(BAF). The $Biobead^{(R)}$ system showed high removal rates of $COD_{Mn}$(76~83%), $BOD_5$(67~88%) and SS(71~91%) for food wastewater with high salt concentration ($>4,000mg/{\ell}$) under short reaction times(2~3hrs). Even at aerobic condition, the system had high treatment efficiency for both T-N (51~63%) and T-P(62~81%). The removal kinetics of $COD_{Mn}$, $BOD_5$, T-N, T-P, and $Cl^-$ in the $Biobead^{(R)}$ system showed a plug-flow pattern with reaction rate constants($hr^{-1}$) of 0.58, 0.63, 0,30, 0.48, and 0.38 respectively. A backwashing process to remove excess biomass and filtered solids was needed at least once during 22-hour operation at $0.5kg\;BOD\;m^{-3}{\cdot}d^{-1}$ loading. At the higher loading($1.0kg\;BOD\;m^{-3}{\cdot}d^{-1}$) the backwashing interval was shorten by 8 hours. The COD, BOD, T-N, and T-P were removed from 43 to 66% only by aerobic biodegradation. The SS was removed over 70% by the filtering of $Biobead^{(R)}$ media in the treatment system. The first one of three serial Biobead reactors showed the highest removal values for $COD_{\alpha}$(52.3%), $COD_{Mn}$(38.8%), BOD(62.5%), and T-N(40.0%). The SS and T-P had the highest removal values(47.5% and 29.2%) at the second one of the serial reactors. The biofilm had non-homogeneous spatial distribution and the colonies were embedded in the sunk area of the Biobead. The thickness of the biofilm was very thin ($5.0{\sim}29.4{\mu}m$) compared to the biofilm thickness($200{\sim}300{\mu}m$) used in other BAF systems.

The Nitrogen and Phosphorus Removal of Municipal Wastewater with CNR Process using Influent as a Carbon Source (유입수를 탄소원으로 이용한 CNR공법의 질소, 인의 제거특성)

  • 김영규;김인배;이영준
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.81-85
    • /
    • 2001
  • The aim of this study was to evaluate on the removal effect of total nitrogen and posphorus in municipal wastewater by decreasing hydraulic retention time(HRT) from 6 hour to 4 hour on CNR process using influent as a Carbon Source. CNR(Cilium Nutrient Romoval) is the process combining $A^2$/O process with cilium media of H2L corporation. The removal efficiencies for BOD$_{5}$, T-N and T-P were 81.1%, 61.4%, 61.4%, respectively. The removal efficiency of nitrogen and posphorus were low by decreasing hydraulic retention time(HRT) from 6 hour to 4 hour on CNR process.s.

  • PDF

A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution (고속도로 현장별 비점오염 저감시설 선정방안 연구)

  • Lee, Yong-Bok;Choi, Sang-Il;Park, Kye-Su;Seong, Il-Jong;Jung, Sun-Kook
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.