  • In monocular vision, bead and eye optokinetic nystagmus (OKN) display directionnal asymmetry, in lower vertebrates such as chickens, T-N stimulation being more efficient in evoking this visuomotor reflex than N-T stimulation. The N-T component of monocular OKN is significantly weaker in chickens. Coil recordings and observation showed that in adult chickens, prolonged monocular visual deprivation by unilateral eyelid suture provoked significant and progressive increase of the N-T component in chickens. This plasticity phenomenon involved the eye and head OKN in chickens. The administration of THIP, a GABA agonist, abolished reversibly the increase of the N-T component in chickens. This fact suggests that the GABAergic system could be involved in determining this plasticity phenomenon observed in adult lower vertebrates.

  • PDF

Application in Ultrafiltration and Reverse Osmosis Module Set with Acrylic Wastewater Pretreated by Coagulation-Filtration-Neutralization Process (응집-여과-중화 공정에 의해 전처리된 아크릴 폐수의 한외여과와 역삼투 모듈 조합 공정에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with coagulation-filtration-neutralization, it was utilized in UF/RO process. After composing of ultrafiltration and reverse osmosis module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. It was found that permeate flux of UF module in module set 4 was about two${\sim}$three times larger than that of UF module in module set 1. Final quantity of permeate from the module set 2 and module set 3 combined with tubular module was shown very good result. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in all UF modules. The removal efficiency of TDS, T-N and COD was very excellent in RO module. Final water quality of acrylic wastewater was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

A Study on the Effect of Chemical Pretreatment for Livestock Wastewater on the Linked Treatment of Sewage (축산폐수 처리 시 화학적 전처리가 연계처리에 미치는 영향 연구)

  • Han, Jun-Suk;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.89-97
    • /
    • 2010
  • In this study, to investigate the effect of chemical pretreatment for livestock wastewater, laboratory scale test for ozonation and linked treatment of sewage were conducted. and the results were obtained as follows. The ozonation of livestock wastewater showed the COD removal rate per hour to be 17%, 78% and 62% at each pH 4, 7 and 10, respectively. With transformation of NBDCOD to biodegradable BDCOD by ozonation, the ratio of SCODcr/TCODcr was increased from 26% to 38%. Accordingly, pretreatment of livestock wastewater affected to the biological post treatment process to elevate removal efficiency by transformation of nonbiodegradable mass to biodegradable mass. As the results of linked treatment of pre-ozonated livestock wastewater and sewage in the MLE process, the treatment efficiencies of TCODcr 93.8%, T-N 74.3%, T-P 89.7%, SS 97.5% were earned at 100% of internal recycle rate. When the internal recycle rate was increased to 150%, the treatment efficiencies of TCODcr 94.5%, T-N 54.5%, T-P 70.8%, SS 98.5% were earned. Also the removal efficiencies of TCODcr 92.6%, T-N 83.1%, T-P 81.9%, SS 98.5% were earned as the internal recycle rate was increased to 200%. Especially, nitrogen removal efficiency in the linked treatment showed 74.3%, 54.5%, 83.1% at 100%, 150% and 200% of internal recycle ratio, respectively, which revealed the tendency of higher removal efficiency than that of sewage treatment.

Comparison and Management of Water Purification Efficiency of Artificial Wetland according to Inflow Water Conditions: Focusing on the Gyeongancheon Basin (유입수 조건에 따른 인공습지 수질 정화효율 비교: 경안천 유역을 중심으로)

  • Seol Jun Lee;Beomjin Eun;Jong Hwan Kim;I Song Choi;Jong-Min Oh
    • Korean Journal of Ecology and Environment
    • /
    • v.57 no.1
    • /
    • pp.28-38
    • /
    • 2024
  • In this study, in order to analyze the water purification efficiency according to the influent water conditions of artificial wetlands, the purification efficiency was compared at two points where sewage treatment water flows in and one point where good effluent flows in. As a result of reviewing the results of the analysis of influent and effluent and the removal efficiency, the T-N and T-P removal efficiency was calculated at 54.7% and 77.4%, respectively, for the two points where sewage treatment water was treated, the treatment efficiency of SS 90.8%, BOD 51.1%, TOC 30.6%, T-N 38.8%, T-P 55.3% was shown. As a result, the efficiency of removing pollutants in the artificial wetland was found to be proportional to the concentration of influent water, and in order to create an efficient artificial wetland, it is judged that thorough review and management at the design stage are necessary considering that the removal efficiency of high-concentration contaminated water was high.

A Study on the Treatment of Landfill Leachate using Membrane and Evaporator (Lab Test) (분리막과 증발기를 이용한 매립지 침출수 처리에 관한 연구 (Lab test))

  • Kang, Shin-Gyung;Park, Yung-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2125-2134
    • /
    • 2000
  • This research was to develope the economical treatment processes of the landfill leachate to meet the legal discharge standards. To achieve this purpose, experiments were conducted in laboratory to choose the optimum process and to obtain the design factors before a pi!ot-scale test. The concept of the process developing in this research was using the reverse osmosis system. The submerged membrane bio-reactor was used to achieve pre-treatment of reverse osmosis system and the concentrate was treated by evaporator with land fill gas as a fuel. The results of the research showed that SS, $BOD_5$, $COD_{cr}$, $NH_4{^+}-N$ and T-N were removed 99.0%, 43.0%, 12.9%, 48.5% and 18.7% respectively in the submerged membrane bio-reactor. The reverse osmosis system could remove $BOD_5$, $COD_{cr}$, $NH_4{^+}-N$ and T-N as an efficiency of97.5%, 97.6%, 79.7% and 85.4% respectively. The evaporator could remove $COD_{cr}$, $NH_4{^+}-N$ and T-N as an efficiency of 90.5%, 50.6% and 63.3% respectively. However the condensed water of the evaporator was not satisfied the legal standard and should be treated in reverse osmosis with the pre-treated leachate.

  • PDF

Development of New BNR Process Using Fixed-Biofilm to Retrofit the Existing Sewage Treatment Plant (고정생물막을 이용한 기존 하수처리장의 생물학적 영양염 제커 신공정개발)

  • Kim, Mi-Hwa;Lee, Ji-Hyung;Chun, Yang-Kun;Park, Tae-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1093-1101
    • /
    • 2000
  • The object of this study was to develop new BNR process using fixed-biofilm which could be applied to retrofit the existing wastewater treatment plant or to introduce as tertiary treatment plant. To achieve complete denitrification from typical raw sewage in Korea, external carbon source must be supplied because $SCOD_{cr}/T-N(NH_4{^+}-N+NOx-N)$of raw sewage was lower than other countries. In this study, the ratio of $SCOD_{cr}/NH_4{^+}-N$ was 2.49 and the influent $NH_4{^+}$-N concentration during the experimental period was varied from 25 to 37 mg/L. To enhance nitrogen removal from the sewage, the two processes using fixed biofilm were adopted as R-Hanoxic/mid.settler/aerobic/anoxic/ aerobic) and R-2(aerobic/mid.settlerlanoxic/anoxic/aerobic), respectively. In the comparison of $NH_4{^+}$-N, T-N effluent quality and T-N removal efficiency in both processes without external carbon source, R-1 process was better than R-2 process for nitrogen removal from raw sewage. With respect to $SCOD_{cr}$/NOx-N ratio and total nitrogen removal in each anoxic reactor of two processes, R-1's was more effective than R-2's for distributing organic matters of raw sewage. In the both processes using fixed biofilm, the amount of required alkalinity to remove unit $NH_4{^+}$-N were 5.18 and 5.76($g{\cdot}CaCO_3/g{\cdot}NH_4{^+}-N_{removed}$), respectively and were lower than activated sludge BNR process(7.14).

  • PDF

A Study on the Limiting Factors in Nitrogen Removal with Fixed Biofilm Process (고정생물막 공법을 이용한 질소제거에 있어서 제한요인에 관한 연구)

  • 지용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.63-68
    • /
    • 1996
  • This study was to discuss limiting factors influenced on the removal efficiencies of nitrogenous compounds investigated using the polypropyrene media which was to attach microorganism in order to apply the fixed-biofilm process. The main limiting factors are the hydraulic retention time (HRT), C/N ratio, $COD/NO_{3}-N$ ratio and temperature. The hydraulic retention time HRT were 6, 8, 10, 12 hrs and the C/N ratio range was 2.5-9.5. The $COD/NO_{3}-N$ ratio range was 3.2-21.9 and the temperature were 15, 20, 25, 30, $35^{\circ}C$, respectively. The results of this study are summerized as follows. 1. Hydraulic retention time (HRT) to obtain removal efficiencies of T-N higher than 85% had to be 10 hrs above. 2. The removal efficiencies of T-N decreased at C/N ratio from 6.2 to 4.8 in this anoxic-contact aeration system. 3. Denitrification rate decreased at $COD/NO$_{3}$-N$ ratio from 8.0 to 5.0 4. As temperature increased, removal efficiencies of T-N increased.

  • PDF

Sequencing batch reactor treating ship sewage and external carbon source (연속 회분식 공정을 이용한 선박오수와 외부탄소원의 혼합처리)

  • Park Sang-Ho;Choi Jeong-Hye;Ko Sung-Chul;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.147-152
    • /
    • 2004
  • In Sequence Batch Reactor (SBR), the removal efficiencies if nutrient materials such as nitrogen and phosphate depend highly on quantity and quality of organic carbon source. Food waste thai contains abundant organic materials has been produced in ship. The applicability if anaerobically fermented if food waste (AFFW) as an external carbon source was examined in the lab-scale SBR process operated at $25^{\circ}C$. With the addition if AFFW increased, average removal efficiencies if $COD_cr$, T-N, T-P changed to $98.5\%,\;95\%,\;93\%$, respectively. Denitrification rate is 0.30g $NO_3-N/g\;VSS{\cdot}day$. In summary, it was suggested tint AFFW sould be used as an economical and effective carbon source for the biological nitrogen and phosphate removal.

  • PDF

Effects of Influent Flow Distribution Ratio and HRT on Sewage Treatment Efficiency of the ASA Process (유입수 분배비와 체류시간이 ASA 공정의 가정오수 처리효율에 미치는 영향)

  • Yang, Eun-Gyoung;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.1
    • /
    • pp.13-24
    • /
    • 2009
  • This study was performed to determine the effect of the influent flow distribution ratio and hydraulic retention time(HRT) on removal of organic matter, nitrogen and phosphorus when domestic sewage was treated by the advanced step aeration(ASA) process. Results of the experiment for the determination of the optimum influent flow distribution ratio between the anaerobic reactor and the anoxic reactor showed BOD removal efficiencies of above 92.0% at all influent flow distribution ratios from 9:1 to 4:6. The highest T-N removal efficiency was 82.6% at the influent flow distribution ratio of 6:4. On the other hand, the highest T-P removal efficiency was 67.8% at the influent flow distribution ratio of 9:1. Considering both the T-N and T-P removal efficiencies, the influent distribution ratio of 6:4 was considered the optimum. Results of the experiment for the determination of the optimum HRT at the optimum influent flow distribution ratio of 6:4 revealed BOD removal efficiencies better than 92.7% at all HRTs from 12hr down to 6hr. The highest T-N and T-P removal efficiency were 82.6% and 59.5%, respectively both at the HRT of 8hr. In conclusion, the optimum influent flow distribution ratio and HRT for treatment of domestic sewage by the ASA process were determined to be 6:4 and 8hr, respectively.

The efficiency variation of UF(tubular)/RO(spiral wound) process using acrylic wastewater treated by different pretreatment processes (아크릴 폐수의 전처리공정에 따른 UF(tubular)/RO(spiral wound) 공정의 성능변화)

  • Lee, Kwang-Hyun;Han, Sung-Bum;Choi, Dae-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.387-394
    • /
    • 2002
  • The efficiency variation of UF(tubular)/RO(spiral wound) process using acrylic wastewater treated by photo-catalyst pretreatment and coagulant-filter-neutralization pretreatment processes were discussed wit the variation of appled pressure and temperature. Ultrafiltration tubular module using acrylic wastewater treated by photo-catalyst pretreatment and coagulant-filter-neutralization pretreatment processes was shown that COD and T-N were not highly affected with the variation of appled pressure and temperature. It was shown that removal efficiency of COD and T-N was low. Removal efficiency of TDS and turbidity with ultrafiltration tubular module was better with the acrylic wastewater by photo-catalyst pretreatment than acrylic wastewater by coagulant-filter-neutralization pretreatment. T-N and TDS were shown high removal efficiency in reverse osmosis membrane process.