• Title/Summary/Keyword: T axis

Search Result 845, Processing Time 0.034 seconds

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.

Variability and Horizontal Structure of Sea Surface Height Anomaly Estimated from Topex/poseidon Altimeter in the East (Japan) Sea (동해의 Topex/Poseidon 고도계로부터 추정된 해면고도이상치의 수평구조와 변동성)

  • Kim, Eung;Ro, Young-Jae;Kim, Chang-Shik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.2
    • /
    • pp.94-110
    • /
    • 2003
  • This study utilizes the dataset of Topex/Poseidon(T/P) altimeter sea surface height (1992-2000 yr., 286 cycles)to investigate the tempore-spatial variability in the East (Japan) Sea. Optimal interpolation (Ol) technique was applied to the pre-processed T/P dataset (level 2) to produce sea surface height anomaly (SSHA) map on regular grids. Spectral analyses of the timeseries of the SSHA at chosen stations and empirical orthogonal function (EOF) analysis of the SSHA in the entire East Sea were made. Distribution of the SSHA can be divided by the southern and northern regions sharply by the polar front situated in the middle of the East Sea. The southern region under the direct influence of the Tsushima Current exhibits higher amplitude of the SSHA fluctuation, while the northern region does relatively smaller one. The spatio-temporal variability of the SSHA in the East Sea can be characterized by the five modes of the EOFs accounting for more than 85% of the total variance. The first mode dominates the SSHA variation in the entire domain with strong seasonal and inter-annual periods accounting for the 72.3% of the total variance. The other modes (up to 5th account for 14%) are responsible for the SSHA variation associated with the local current system, meandering of the polar frontal axis, and mesoscale eddies. Spectral peaks with significant confluence level show semi-annual, annual and interannual (2, 3-4 years) periods.

The Study on the Construction Criteria and Dujabee Technique of the Construction of the Cheomseongdae (첨성대축조 규준방식과 드잡이기술에 대한 기술사적 접근 연구)

  • Kim, Derk Moon
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.4
    • /
    • pp.92-103
    • /
    • 2012
  • The Cheomsungdae was built in the Silla dynasty during the reign of queen Seondeok. It has a round cylindrical structure with a flowing curved fa ade. The identity of the Cheomsungdae has not been revealed since there is not much historical evidence or documents about the building. This study is trying to investigate the building technique and method from the technical point of view of the past when it was constructed. There have been much work and studies done for the Cheomsungdae, but not much were focusing on the technical aspects of the building. In addition there are many questions and doubts about the hypothesis of the building technique of Cheomsungdae since there aren't any remaining documents or historical evidence supporting it. Among many questions, we think that the discussion on falsework technique is not considering traditional construction method of the Dujabee (a traditional construction technique using various tools and equipment for the stability of the building) technique. Therefore, it is hard to identify them as reliable historical facts. As the result of the study, we want to provide the basic data on the construction techniques of Korean traditional architecture and broaden the study scope of technical history by narrowing the errors. The study could be summarized into three points. 1. The historical architecture Cheomseongdae was constructed by using traditional crane techniques such as a Noklo (pulley ladder). Cheomseongdae was re-evaluated as a high level technology for the history of architecture. 2. The benchmark method on Cheomseongdae construction has been applied with a precise scientific method based on the geometrical principals using the central axis. 3. In terms of the history of Korean traditional architecture technology, as there aren't many studies done we proposed various basic data for the traditional crane techniques and criteria of Korean traditional architecture technology. We could expect various and active studies for the technical approach of the history of architecture.

Analysis of Quality Improvement of a Floating Image Using a Hybrid Retroreflective Mirror Array Sheet (혼성-병풍형 구조의 재귀반사 거울 배열판을 이용한 부양영상 개선 분석)

  • Yu, Dong Il;Baek, Young Jae;Yong, Hyeon Joong;O, Beom Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.4
    • /
    • pp.142-145
    • /
    • 2019
  • Normally, a corner cube retroreflector (CCRR) sheet is used as a retroreflective mirror array (RRMA) in a volumetric display. Each CCRR unit reflects light in the retroreflective direction, which is parallel to the incident light, and it makes a blurred image, as it shifts the position of light within its dimensions. Adopting a "curved planar wall" and "parabolic focusing" (x-axis), a hybrid-t(transverse direction)-RRMA is proposed, to improve the image quality and brightness. The improvement of image contrast is achieved by tuning a "linear v-shaped groove" structure to a "parabolic v-shaped groove". Also, the system has been simplified and the brightness enhanced 4 times by removing the half mirror.

C7 Fracture as a Complication of C7 Dome-Like Laminectomy : Impact on Clinical and Radiological Outcomes and Evaluation of the Risk Factors

  • Yang, Seung Heon;Kim, Chi Heon;Lee, Chang Hyun;Ko, Young San;Won, Youngil;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.575-584
    • /
    • 2021
  • Objective : Cervical expansive laminoplasty is an effective surgical method to address multilevel cervical spinal stenosis. During surgery, the spinous processes of C2 and C7 are usually preserved to keep the insertion points of the cervical musculature and nuchal ligament intact. In this regard, dome-like laminectomy (undercutting of C7 lamina) instead of laminoplasty is performed on C7 in selected cases. However, resection of the lamina can weaken the C7 lamina, and stress fractures may occur, but this complication has not been characterized in the literature. The objective of the present study was to investigate the incidence and risk factors for C7 laminar fracture after C7 dome-like laminectomy and its impact on clinical and radiological outcomes. Methods : Patients who underwent cervical open-door laminoplasty combined with C7 dome-like laminectomy (n=123) were classified according to the presence of C7 laminar fracture. Clinical parameters (neck/arm pain score and neck disability index) and radiologic parameters (C2-7 angle, C2-7 sagittal vertical axis, and C7-T1 angle) were compared between the groups preoperatively and at postoperatively at 3, 6, 12, and 24 months. Risk factors for complications were evaluated, and a formula estimating C7 fracture risk was suggested. Results : C7 lamina fracture occurred in 32/123 (26%) patients and occurred at the bilateral isthmus in 29 patients and at the spinolaminar junction in three patients. All fractures appeared on X-ray within 3 months postoperatively, but patients did not present any neurological deterioration. The fracture spontaneously healed in 27/32 (84%) patients at 1 year and in 29/32 (91%) at 2 years. During follow-up, clinical outcomes were not significantly different between the groups. However, patients with C7 fractures showed a more lordotic C2-7 angle and kyphotic C7-T1 angle than patients without C7 fractures. C7 fracture was significantly associated with the extent of bone removal. By incorporating significant factors, the probability of C7 laminar fracture could be assessed with the formula 'Risk score = 1.08 × depth (%) + 1.03 × length (%, of the posterior height of C7 vertebral body)', and a cut-off value of 167.9% demonstrated a sensitivity of 90.3% and a specificity of 65.1% (area under the curve, 0.81). Conclusion : C7 laminar fracture can occur after C7 dome-like laminectomy when a substantial amount of lamina is resected. Although C7 fractures may not cause deleterious clinical outcomes, they can lead to an unharmonized cervical curvature. The chance of C7 fracture should be discussed in the shared decision-making process.

Cone-beam computed tomographic evaluation of mandibular incisor alveolar bone changes for the intrusion arch technique: A retrospective cohort research

  • Lin Lu;Jiaping Si;Zhikang Wang;Xiaoyan Chen
    • The korean journal of orthodontics
    • /
    • v.54 no.2
    • /
    • pp.79-88
    • /
    • 2024
  • Objective: Alveolar bone loss is a common adverse effect of intrusion treatment. Mandibular incisors are prone to dehiscence and fenestrations as they suffer from thinner alveolar bone thickness. Methods: Thirty skeletal class II patients treated with mandibular intrusion arch therapy were included in this study. Lateral cephalograms and cone-beam computed tomography images were taken before treatment (T1) and immediately after intrusion arch removal (T2) to evaluate the tooth displacement and the alveolar bone changes. Pearson's and Spearman's correlation was used to identify risk factors of alveolar bone loss during the intrusion treatment. Results: Deep overbite was successfully corrected (P < 0.05), accompanied by mandibular incisor proclination (P < 0.05). There were no statistically significant change in the true incisor intrusion (P > 0.05). The labial and lingual vertical alveolar bone levels showed a significant decrease (P < 0.05). The alveolar bone is thinning in the labial crestal area and lingual apical area (P < 0.05); accompanied by thickening in the labial apical area (P < 0.05). Proclined incisors, non-extraction treatment, and increased A point-nasion-B point (ANB) degree were positively correlated with alveolar bone loss. Conclusions: While the mandibular intrusion arch effectively corrected the deep overbite, it did cause some unwanted incisor labial tipping/flaring. During the intrusion treatment, the alveolar bone underwent corresponding changes, which was thinning in the labial crestal area and thickening in the labial apical area vice versa. And increased axis change of incisors, non-extraction treatment, and increased ANB were identified as risk factors for alveolar bone loss in patients with mandibular intrusion therapy.

The Outcome of Postoperative Radiation Therapy for Patients with Stage II Pancreatic Cancer (T3 or N1 Disease) (2기(T3 또는 N1) 췌장암 환자들의 수술 후 방사선치료의 성적 및 고찰)

  • Kim, Sang-Won;Kim, Myung-Wook;Kim, Wook-Hwan;Kang, Seok-Yun;Kang, Seung-Hee;Oh, Young-Taek;Lee, Sun-Young;Yang, Ju-No;Chun, Mi-Sun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.213-218
    • /
    • 2007
  • Purpose: To analyze retrospectively the outcome of postoperative radiation therapy with or without concurrent chemotherapy for curatively resected stage II pancreatic cancer with T3 or N1 disease. Materials and Methods: Between January 1996 and December 2005, twenty-eight patients completed adjuvant radiation therapy at Ajou University Hospital. The patients had either pathologic T3 stage or N1 stage. The radiation target volume encompassed the initial tumor bed identified preoperatively, resection margin area and celiac nodal area. In the case of N1 patients, the radiation field extended to the lower margin of the L3 vertebra for covering both para-aortic lymph nodes bearing area. The median total radiation dose was 50 Gy. Ten patients received concurrent chemotherapy. Results: Thirteen patients (46%) showed loco-regional recurrences. The celiac axis nodal area was the most frequent site (4 patients). Five patients showed both loco-regional recurrence and a distant metastasis. Patients with positive lymph nodes had a relatively high probability of a distant metastasis (57.1%). Patients that had a positive resection margin showed a relatively high local failure rate (57.1%). The median disease-free survival period of all patients was 6 months and the 1-and 2-year disease free survival rates were 27.4% and 8.2%, respectively. The median overall survival period was 9 months. The 2-and 3-year overall survival rates were 31.6% and 15.8%, respectively. Conclusion: The pancreatic cancer patients with stage II had a high risk of local failure and a high risk of a distant metastasis. We suggest the concurrent use of an effective radiation-sensitizing chemotherapeutic drug and adjuvant chemotherapy after postoperative radiation therapy for the treatment of patients with stage II pancreatic cancer.

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Alterations in Thyroid Hormone Levels After Open Heart Surgery (개심술 후 갑상선 호르몬치 변화에 대한 연구)

  • 김광휴;조삼현
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.131-136
    • /
    • 1997
  • The hemodynamic effects of thyroid hormones which is well established, affect myocardial contractility, heart rate, and myocardial oxygen consumption. The alterations in thyroid function test are frequently seen in patients with nonthyroidal illness and often correlate with the severity of the illness and the prosnosis. In this study, thyroid hormone changes were investigated in 20 patients who received cardiopulmonary bypass(CPB). All patients showed a state of biochemical euthyroidism preoperatively: The results were as follows : 1. Serum triiodothyronine(73) reached to its nadir(30.05 $\pm$ 17.5ng/dl, p(0.001) at 10 minutes after the start of CPB and remained low(p(0.05) throughout the study period. 2. Serum thyroxine(74) concentr tion slightly decreased after CPB, but maintained within normal range. 3. Serum free thyroxine(W4) concentration slightly increased after CPB, but maintained within normal range. 4. Serum thyroid stimulating hormone(TSH) concentration increased 10 minute after CPB, reached to its nadir(3.37 $\pm$ 0.81u1U/m1, p(0.001) at 2 hours after CPB. After then, serum TSH concentration decreased and reached its normal levels at 24 hours after CPB. 5. The patients whose postoperative recovery was uneventful(Group 1) had higher serum 73 levels than those who had postoperative complications(Group 2)(p<0.05). Group 1 showed elevating patterns of serum 73 in the fourth day after operation, whereas group 2 did not show such an elevating pattern. These findings are similar to the euthyroid sick syndrome seen in severely ill patients and indicate that patients undergoing open heart surgery have suppression of the pituitary-thyroid axis.

  • PDF

Comparison on the Fracture Strength Depending on the Fiber Post and Core Build-up (섬유 강화 포스트와 코어 축성 방법에 따른 파절 강도에 관한 비교)

  • Lee, Ja-Hyoung;Shin, Sooyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.225-235
    • /
    • 2009
  • A common procedure of restoration of endodonticlly treated tooth with fiber-reinforced post is followed by core build-up after post cementation. However, this technique is complex and time-consuming. The aim of this study was to compare fracture strength of premolar, restored with various methods of core fabrications on fiber-reinforced posts and casting metal restoration. Forty five freshly extracted human mandibular premolars were obtained and devided into 5 groups acconding to the type of post and methods of core build-up. In Group A, D.T. $Light-post^{(R)}$ were cemented with $DUO-LINK^{TM}$ and then $LIGHT-CORE^{TM}$ was used for core restoration. In Group B, D.T. $Light-post^{(R)}$ and $DUO-LINK^{TM}$ were used for cementing in the postspace, and $DUO-LINK^{TM}$ was used again for core restoration. In Group C, $Light-post^{(R)}$ bonding and the core build-up were performed simultaneously by using $DUO-LINK^{TM}$. In Group D, $LuxaPost^{(R)}$ was bonded by using $LuxaCore^{(R)}-Dual$. Again, $LuxaCore^{(R)}-Dual$ was used for core restoration. In Group E, $LuxaPost^{(R)}$ bonding and the core build-up were performed simultaneously by using $LuxaCore^{(R)}-Dual$. Axial reduction was formed parallelly as possible and 45 degree bevel was made at buccal occlusal surface. Crowns were fabricated and cemented. Each tooth was embedded in self-curing acrylic resin to the level of 2mm below the CEJ. Specimens were fixed on universal testing machin such that the axis of the tooth was at 45 degree inclination to the horizontal plane, and compressive force was applied at a crosshead speed of 1mm/min until failure occurred. The mean fracture strength was the highest in group A followed by descending order in group B, D, E and C. However, there were no statistically significant differences between groups with regard to the fracture strength. The type of the post or build-up methods of the core does not seem to influence the fracture strength.