• Title/Summary/Keyword: T axis

Search Result 845, Processing Time 0.028 seconds

Fabrication of six-beam accelerometer with self-eliminated off-axis sensitivity by summing circuit (합산회로를 통하여 타축감도가 자체상쇄된 6빔 가속도센서의 제조)

  • 심준환;김동권;이종현
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.33-39
    • /
    • 1998
  • A six-beam accelerometer with self-compensated off-axis sensitivity was fabricated onthe selectively diffused (111)-oriented n/n$^{+}$/n silicon substrates by a unique porous silicon micromachining technique, which has self-stip characteristics and highly seletive formation of porous silicon layer during anodic reaction. Also, the characteristics of the fabricated accelerometer were investigated. The sensitivity of the acceleormeter added up outputs of three bridges through a summing circuit was 0.68 mV/g and the nonlinearity was less than 2% of the full scale output. The measured first resonant frequency was 4.236 kHz. When the outputs of three bridges were compared to summing output of bridges obtained through summing circuit, the normal output for Z-axis acceleration exhibited the same value s summing outputs of three bridges without reduction of sensitivity and thus the sensitivity decrease due to additional beam was compensated. Although a maximum off-axis sensitivity in one bridge of the accelerometer showed 17% of normal sensitivity, the off axis sensitivity obtained from summing output of three bridges decreased to 1.0%. Therefore, the self-elimination of off-axis sensitivity can be simply realized by obtaining the output of the sensor through summing circuit.t.

  • PDF

NMR Chemical Shift for a 4d$^1$ system when the Threefold Axis is Chosen to be the Axis of Quantization

  • Ahn, Sang-Woon;Yuk, Geun-Young;Ro, Seung-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 1986
  • The NMR chemical shift arising from 4d electron angular momentum and 4d electron spin dipolar-nuclear spin angular momentum interaction for a $4d^1$ system in a strong crystal field of octahedral symmetry, when the threefold axis is chosen as the quantization axis, has been investigated. A general expression using a nonmultipole expansion method is derived for the NMR chemical shift. From this expression all the multipolar terms are determined. We find that the nonmultipolar results for the NMR chemical shift ${\Delta}B$, is exactly in agreement with the multipolar results when $R {\ge} 0.20$ nm. It is also found that the 1/$R^7$ term contributes to the NMR chemical shift almost the same as the 1/$R^5$ in magnitude. The temperature dependence analysis of ${\Delta}B$/B(ppm) at various values of R shows that the 1/$T^2$ term has the dominant contribution to the NMR chemical shift but the contributions of other two terms are certainly significant for a $4d^1$ system in a strong crystal field of octahedral symmetry when the threefold axis is chosen to be the axis of quantization.

Vibration Suppression control for an Articulated Robot: Effects of Model-Based Control Applied to a Waist Axis

  • Collier, T.;Itoh, Masahiko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.31.4-31
    • /
    • 2001
  • This paper deals with a control technique of eliminating the transient vibration of a waist axis of an articulated robot. This technique is based on a model-based control in order to establish the damping effect on the mechanical part. The control model is composed of reduced-order electrical and mechanical parts. This model estimates a load speed converted to the motor shaft. The difference between the estimated load speed and the motor speed is calculated dynamically and is added to the velocity command to suppress the transient vibration of a waist axis of the arm. This control model is easily obtained from design or experimental data and can be easily integrated into a DSP. This control technique is applied to a waist axis of an articulated robot composed of a harmonic drive ...

  • PDF

Design of a Four-axis Force/Moment Sensor for Measuring the Applied Force to Wrist (손목에 가해지는 힘측정을 위한 4축 힘/모멘트센서 설계)

  • Hong, Tae-Kyung;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.1011-1016
    • /
    • 2013
  • Patients have the paralysis of their wrists, and can't use of their wrists freely. But their wrists can be recovered by wrist-bending rehabilitation exercise. Professional rehabilitation therapeutists exercise the wrists of patients in hospital. But the wrists of patients have not exercised enough for the rehabilitation, because the therapeutists are much less than patients in number. Therefore, the wrist rehabilitation robot should be developed, and it have to measure the applied force to the patients' wrists for their safety. In this paper, the four-axis force/moment sensor was designed for the wrist rehabilitation robot. As a test results, the interference error of the four-axis force/moment sensor was less than 0.91%. It is thought that the sensor can be used to measure the applied force to the patients' wrists.

The Development of An Error Measurement System of 5-Axis Mill & Turn Machine Tool by Double Ball Bar Test (DBB를 이용한 5축 복합가공기의 오차 측정 시스템 개발에 관한 연구)

  • Kim T.H.;Jung Y.G.;Ko H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.243-244
    • /
    • 2006
  • In this paper, the development of an error measurement system of 5-axis mill & turn machine tool presented by double ball bar test, which has been widely used to measure the overall accuracy of machining center. and the reliability of an error measurement system of 5-axis mill & turn machine tool was secured by the direct cutting test.

  • PDF

Design of a Three-Axis Force Sensor for Wrist Bending-Exercise Rehabilitation Robot (손목굽힘운동 재활로봇을 위한 3축 힘센서 설계)

  • Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.118-123
    • /
    • 2013
  • Most serious stroke patients have the paralysis of their wrists, and can't use of their hands freely. But their wrists can be recovered by rehabilitation exercise. Recently, professional rehabilitation therapeutists exercise the wrists of stroke patients in hospital. But the wrists of stroke patients have not rehabilitated, because the therapeutists are much less than stroke patients in number. Therefore, the wrist bending-exercise rehabilitation robot that can measure the bending force of the patients' wrists is developed. In this paper, the three-axis force sensor was designed for the wrist bending-exercise rehabilitation robot. As a test results, the interference error of the three-axis force sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist bending force of the patient.

Study on the Neutral Axis of Glulam and its Mechanical Properties (적층목질재(積層木質材)(Glulam)의 중립축(中立軸)과 강도적(强度的) 성질(性質)에 관한 연구(硏究))

  • Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.42-52
    • /
    • 1990
  • In this study, thick 24mm glulams were composed of thick. 3, 4, 6, 8mm Larch laminas to study that the theoretical analysis and the experimental analysis regarding the location of neutral axis of the glulams were compared, and to study on the effect of location of neutral axis on mechanical properties of glulam. The variation of location of neutral axis after proportional limit(or elastical limit) was studied to offer basic data to make the better composition method of glulam. The result obtained can be summarized as follows: 1. The theoretical neutral axis was 0.547 in solid wood, and also 0.547 in glulams because glulams were composed of only Larch laminas. 2. In solid wood, the deviation of the theoretical and the experimental neutral axis location was 0.1%, But in glulams, the deviation from-12.2% to + 7.8% showed nonuniform pattern but no large deviation. Because laminas was only of Larch and so the mechanical properties of laminas were monotonous. 3. The neutral axis exerted no influance on the elasticity of glulam, which meaned that the maximum shear strength in the neutral axis showed no influance on elasticity limit. 4. The only minutely lower elasticities of glulam than that of solid wood were shown. This was because of influance of glue lines of glulam on the elasticlties. 5. The failure type of glulam was wholly simple tension failure and the horizontal shear failure near neutral axis was not taken place, which was that glue line was complete in bonding and the strength of the lamina was not various but uniform. 6. The ratio of tension strain($^{\varepsilon}t$) I compression strain($^{\varepsilon}c$) initially showed uniform level After the elasticity limit. the ratio was increased with the flow of time and so the tension strain was more increased than compression strain. So this proved tension lamination technique, which is that the mechanical properties of glulam could be improved, if the lamina of more superior strength would he added on the bottom side of the glulam.

  • PDF

Rate-Dependence of Off-Axis Tensile Behavior of Cross-Ply CFRP Laminates at Elevated Temperature and Its Simulation

  • Takeuchi, Fumi;Kawai, Masamichi;Zhang, Jian-Qi;Matsuda, Tetsuya
    • Advanced Composite Materials
    • /
    • v.17 no.1
    • /
    • pp.57-73
    • /
    • 2008
  • The present paper focuses on experimental verification of the ply-by-ply basis inelastic analysis of multidirectional laminates. First of all, rate dependence of the tensile behavior of balanced symmetric cross-ply T800H/epoxy laminates with a $[0/90]_{3S}$ lay-up under off-axis loading conditions at $100^{\circ}C$ is examined. Uniaxial tension tests are performed on plain coupon specimens with various fiber orientations $[{\theta}/(90-{\theta})]_{3S}$ ($\theta$ = 0, 5, 15, 45 and $90^{\circ}C$) at two different strain rates (1.0 and 0.01%/min). The off-axis stress.strain curves exhibit marked nonlinearity for all the off-axis fiber orientations except for the on-axis fiber orientations $\theta$ = 0 and $90^{\circ}$, regardless of the strain rates. Strain rate has significant influences not only on the off-axis flow stress in the regime of nonlinear response but also on the apparent off-axis elastic modulus in the regime of initial linear response. A macromechanical constitutive model based on a ply viscoplasticity model and the classical laminated plate theory is applied to predictions of the rate-dependent off-axis nonlinear behavior of the cross-ply CFRP laminate. The material constants involved by the ply viscoplasticity model are identified on the basis of the experimental results on the unidirectional laminate of the same carbon/epoxy system. It is demonstrated that good agreements between the predicted and observed results are obtained by taking account of the fiber rotation induced by deformation as well as the rate dependence of the initial Young's moduli.

Effects of Sodium Bicarbonate on Electrocardiogram in Hyperkalemia (과칼륨혈증의 심전도변화와 중조(重曹)투여가 이에 미치는 영향)

  • Cho, Young-Ho;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 1982
  • The effects of $NaHCO_3$ on the electrocardiogram of rats were studied in the induced hyperkalemia. The subjects were divided into 4 groups: the group 1 was normal control and the data on this normal control had teen obtained from the following three groups before administration of KCl or $NaHCO_3$, the group 2 (KCl) was administered 40 ml per kg body weight of the 10 per cent KCl solution, the group 3 $(NaHCO_3)$ was administered 40 ml per kg body weight of the 10 per cent $NaHCO_3$ solution, and the group 4 $(KCl+NaHCO_3)$ was received 10 per cent KCl, which was followed by administration of 10 per cent $NaHCO_3$ at one and half hours later. In KCl, the heart rate was decreased rapidly, and then maintained its level, later rapid decreasing heart rate was followed by the cardiac stand still. The mean electrical axis of QRS complex became progressively deviated to the left. The amplitude of T wave was increased transiently but was not changed thereafter. There was prolongation of the P-Q interval and the Q-T interval at the beginning and then they were shortened. In $NaHCO_3$, the heart rate was decreased rapidly at the beginning, later showed a tendency of recovery. The mean electrical axis of QRS was not changed initially, but later became deviated to the left. The amplitude of T wave was not changed. There was prolongation of the P-Q interval and the Q-T interval at the beginning and then they were shortened. In $KCl+NaHCO_3$, there were a tendency of recovery of both the amplitude of the T wave and the electrical axis of the QRS complex after administration of $NaHCO_3$ but the heart rate was not recovered. There was prolonged P-Q interval, but the Q-T interval was relatively unchanged.

  • PDF