• 제목/요약/키워드: T/S bolts

검색결과 26건 처리시간 0.02초

고장력볼트 냉간압조용 비조질강 특성에 관한 연구 (Mechanical Properties and Workability of Non Heat Treated Steel on Cold Forming of High Tension Bolts)

  • 황범규;정택우;이영선;최정묵;문영훈
    • 소성∙가공
    • /
    • 제19권4호
    • /
    • pp.210-216
    • /
    • 2010
  • The importance and interests for saving of energy and cost in industry has grown up. Therefore, process optimization to reduce the process and energy become one of the most important things. The non-heat treated steel, post-heat-treated is no necessary, has attractive points as structural materials. However, establishment of mechanical properties is necessary to apply non-heat-treated steel to structural parts. In this study, for non-heat-treated steel and pre-heat-treated steel, we have investigated microstructure, hardness, the tensile strength, compressive strength. And the FE analysis technology to predict the hardness value of forged part is developed on micro-alloyed steel forged part.

T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향 (Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device)

  • 공창덕;방조혁;이정환
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

섬유금속적층판 제작을 위한 PTFE 몰드 기반 마이크로파 공정에 대한 실험적 연구 (Experimental Study on Manufacturing Fiber Metal Laminate using Microwave Heating Based on PTFE Mold)

  • 박으뜸;이영헌;김정;강범수;송우진
    • 소성∙가공
    • /
    • 제29권4호
    • /
    • pp.179-187
    • /
    • 2020
  • Existing composite forming processes such as the autoclave, prepreg compression forming (PCF), RTM, etc. require high production costs because of their long processing time. On the other hand, microwave heating process (MHP) can reduce the production costs since both mold and composite material can be heated directly. The aim of this study is to manufacture a mold consisting of polytetrafluoroethylene (PTFE), quartz glass, stainless steel clamps, and polyether ether ketone (PEEK) bolts for fabricating FML based on self-reinforced polypropylene (SRPP) using the MHP. First, the flame test was carried out prior to the MHP to check the temperature on the mold and whether the spark occurred at the mold and the edge of the FML. Second, the uniaxial tensile test was then conducted to obtain the mechanical properties of the FML manufactured by the MHP. The mechanical properties were compared with those of the FML fabricated by the PCF. As a result, the MHP using the PTFE mold can manufacture the FML more rapidly than the PCF, and obtain acceptable mechanical properties.

이형 하부다이아프램으로 보강된 각형 CFT 기둥-보 접합부의 내진성능에 관한 연구 (A Study on Seismic Performance for CFT Square Column-to-Beam Connections Reinforced with Asymmetric Lower Diaphragms)

  • 최성모;윤여상;김요숙;김진호
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.579-589
    • /
    • 2003
  • 콘크리트충전 강판(CFT)기둥과 H-형강 보 접합부의 기존 보강 방식은 상 하 동일 다이아프램 형태로 처리하는 것이 일반적이지만, 우리나라와 같은 중 약진지역에서는 하부플랜지에 인장 발생률이 적으므로 하부측을 단순화시켜 경제적인 접합부를 만들 수 있다. 우선적으로 본 논문에서는 단순인장실험을 실시하여 인장거동을 파악하고, 그 결과를 확장 적용하여 하부측 단순화의 타당성을 검증하였다. 본 실험에서는 상부에 복합십자형 다이아프램(Combined Diaphragm)을 하부에는 네 가지 형식 즉, 복합십자형, 무보강, 수평 T-bar, 수직 Plate를 다아아프램으로 제작한 실대크기의 실험체를 ANSI/AISC SSPEC-2002 가력 프로그램(AISC,2002)에 따라 반복가력실험을 하였다. 하부다이아프램에 사용된 수평 T-bar와 수직 Flat bar의 스터드 볼트는 횡력에 의해 하부다이아프램에 인장력이 가해질 때 보 플랜지의 인장력을 내부 콘크리트에 전달하기 위함이다. 각각의 실험체는 하부 인장시 내력의 차이가 조금 있었으나 모든 실험체가 AISC에서 규정하고 있는 합성보통모멘트 골조인(AISC,2002) 0.01rad의 비탄성회전 능력을 발휘하였다. 하부 접합부의 거동을 분석한 결과, 단순화된 하부다이아프램은 내력과 강성뿐만 아니라 소성 변형 능력이 우수하며 현장에 사용하기에 충분한 내진성능을 나타냄을 입증하였다.

좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과 (Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device)

  • 공창덕;이정환
    • Composites Research
    • /
    • 제15권4호
    • /
    • pp.23-31
    • /
    • 2002
  • 시편 게이지 면적($길이{\;}{\times}{\;}폭$)의 이차원 크기효과가 T300/924 $[45/-45/0/90]_3s$ 탄소섬유/에폭시 적층판의 압축거동에 대해 조사하였다. 개조된 압축시험치구(ICSTM)와 좌굴방지장치가 $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm,{\;}90mm{\;}{\times}{\;}90mm$의 게이지 길이와 폭을 가진 시편들의 압축시험에 사용하였다. 모든 경우의 파괴들은 시편 게이지 길이 내에서 주로 갑자기 발생하였다. 파괴 후 분석결과는 $0^{\circ}$층의 섬유의 미소좌굴에 의해 파괴를 시작하여 최종파괴를 일으키는 임계파괴기구일 것으로 생각되었다. 이것은 매트릭스 지배적인 파괴를 의미하며, 초기섬유굴곡에 따라 파괴가 지배적으로 시작된다는 것을 말한다 이것은 또한 제작공정과 품질이 압축강도를 결정하는 중요한 역할을 한다고 볼 수 있다. 좌굴방지장치를 장착하고 시험할 때 장치의 볼트 조임 토크에 따라 시편과의 접촉마찰 등에 의해 실제 압축강도 보다 크게 나타나는 결과를 보였다. 좌굴방지장치의 영향을 유한요소법을 이용하여 해석한 결과 실제 압축강도 보다 7% 정도 크게 나타남을 확인하였다. 부가적으로 홀을 갖는 시편들의 압축시험도 수행되었다. 홀에 의한 국부응력집중이 적층판 강도에 지배적 요인이었다. 파괴강도는 홀 크기와 시편 폭이 증가할수록 감소하였으나 탄성응력집중계수로 예측된 값보다는 일반적으로 크게 나타났다. 이것은 사용된 복합재가 이상적인 취성재질이 아니라는 것을 의미하며 홀 주위에서 다소간의 응력이완이 발생한다고 볼 수 있다. X선 검사 사진분석에서 섬유좌굴과 층간분리형태의 손상이 파괴하중의 약 80%에서 홀 가장자리로부터 시작되었고 임계파괴크랙길이인 2-3mm의 불안정한 상태에 도달하기 전까지는 하중 증가와 더불어 안정되게 파괴가 진전되었다(시편의 기하학적 크기에 의존함). 이 손상과 파괴는 선형 cohesive zone 모델로 해석되었다. 노치없는 시편의 압축강도와 평면 파괴인성의 측정된 적층판 변수들을 사용하여 홀의 크기와 시편 폭의 함수로서 홀을 갖는 적층판의 압축강도를 성공적으로 예측하였다.

SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가 (Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel)

  • 오상훈;최영재;윤성기;이동규
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.271-280
    • /
    • 2010
  • 본 연구에서는 국내 건축 구조용 강재인 SN490 강재를 사용하여 실물 크기의 H형강 보와 기둥으로 구성된 모멘트저항골조의 외부 T자형 용접모멘트접합부를 대상으로 실험을 계획하였다. 실험변수를 용접접근공형상, 접합부 이음 방식, RBS(Reduced Beam section)로 하여 9개의 시험체를 제작하였고, 반복재하 실물대 실험을 수행하였다. 실험에 따른 각 시험체의 파괴형태 및 모멘트-층간변위 관계, 변형률 분포를 나타내었으며, 재료인장 실험을 통하여 실험에 사용된 시험체의 전소성모멘트를 구한 다음 특수모멘트 접합부에 해당하는 시험체를 분류하였다. 각 시험체의 모멘트-층간변위 곡선을 골격곡선과 바우싱거곡선으로 분리하여 내력상승률, 소성배율, 에너지 소산량 등을 나타내었으며 이를 가지고 각 시험체의 소성변형능력을 평가하였다. 실험결과 용접접근공이 제거된 시험체가 기존 용접접근공형상을 가지는 시험체에 비하여 우수한 내진성능을 나타내었고, 보 웨브를 용접과 볼트를 병행하고 전단탭을 전체에 걸쳐 보강 용접한 시험체가 가장 우수한 내진성능을 나타내었다.