• Title/Summary/Keyword: T/R probe

Search Result 96, Processing Time 0.029 seconds

Comparison of ECT Probes in Diagnosis of Defects

  • Mun, Ho-Young;Kim, Chang-Eob
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.190-196
    • /
    • 2014
  • In this paper, the characteristics of a defective elliptical aluminum plate are analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.

Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe

  • Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • In this paper, the eddy current signals come from a pair oi transmit-receive (T/R) pancake coil on ECT array Probe are analyzed with the variations of the lift-of and of the distance between transmit and receive coils. To obtain the electromagnetic characteristics of the probes, the governing equation describing the eddy current problems is derived from Maxwell's equation and is solved using three-dimensional finite element method. Eddy current signals from T/R coils on ECT array probe have quite different characteristics compared with ones from impedance coil on rotating pancake coil probe. The results in this paper ran be helpful when the field eddy current signals from ECT array probe are evaluated.

Measurement of the Three-Dimensional Flow Fields of a Gun-Type Gas Burner Using Triple Hot-Wire Probe (3중 열선 프로브를 이용한 Gun식 가스버너의 3차원 유동장 측정)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.23-31
    • /
    • 2006
  • Mean velocities and turbulent characteristics in the three-dimensional flow fields of a gun-type gas burner were measured by using triple hot-wire probe (T-probe) in order to compare them with the results already presented by X-type hot-wire probe (X-probe). Vectors obtained by the measurement of two kinds of probes in the horizontal plane and in the cross section respectively show more or less difference in magnitude each other, but comparatively similar shape in overall distribution. Axial mean velocity component along the centerline shows that the value by T-probe is about ten times smaller than that by X-probe above the range of X/R=3. Also, the axial component of turbulent intensity along the centerline appears the biggest difference between the two probes. Moreover, axial mean velocity component, axial turbulent intensity component and rotational along the Y-directional distance show a big difference between slits and swirl vanes. On the whole, the values by T-probe appear smaller than those by X-probe.

  • PDF

SYNTHESIS AND APPLICATION OF NEW SPIN PROBES

  • Kim, S.D.;Freeman, H.S.;Mcgregor, R.
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1990.06b
    • /
    • pp.67-67
    • /
    • 1990
  • Three non-ionic and two anioinic spin probes, differing in size and substituent, were synthesized. Their mobility in dried nylon 6 film was investicated by the spin probe technique using electron spin resonance spectrometer. When the size of a spin probe was large and the interaction between the probe molecules and polymer chains existed, the mobility of spin probes decreased. From Arrhenius plots of rotational correlation time, one discontinuity point ($T_d$) was determined. The activation energies for rotation below and above $T_d$ were discussed in terms of the mode of probe rotation. Three spin probes could be viewed as azo dyes having a built-in nitroxide radical. Photolysis of them in dimethylformamide and in nylon 6 film was performed by exposure to 254 nm UV light in the presence of air. It was found that dyes having a built-in nitroxide radical showed better photostability than dyes derived from ${\bata}-naphthol$..

  • PDF

Pathogen-Imprinted Polymer Film Integrated probe/Ti3C2Tx MXenes Electrochemical Sensor for Highly Sensitive Determination of Listeria Monocytogenes

  • Xiaohua, Jiang;Zhiwen, Lv;Wenjie, Ding;Ying, Zhang;Feng, Lin
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.431-437
    • /
    • 2022
  • As one of the most hazardous and deadliest pathogens, Listeria monocytogenes (LM) posed various serious diseases to the human being, thus designing effective strategy for its detection is of great significance. In this work, by preparing Ti3C2Tx MXenes nanoribbon (Ti3C2TxR) as carrier and selecting thionine (Th) acted simultaneously as signal probe and functional monomer, a LM pathogen-imprinted polymers (PIP) integrated probe electrochemical sensor was design to monitor LM for the first time, that was carried out through the electropolymerization of Th on the Ti3C2TxR/GCE surface in the existence of LM. Upon eluting the templates from the LM imprinted cavities, the fabricated PIP/Ti3C2TxR/GCE sensor can rebound LM cells effectively. By recording the peak current of Th as the response signal, it can be weakened when LM cell was re-bound to the LM imprinted cavity on PIP/Ti3C2TxR/GCE, and the absolute values of peak current change increase with the increasement of LM concentrations. After optimizing three key parameters, a considerable low analytical limit (2 CFU mL-1) and wide linearity (10-108 CFU mL-1) for LM were achieved. In addition, the experiments demonstrated that the PIP/Ti3C2TxR sensor offers satisfactory selectivity, reproducibility and stability.

Development of Prevotella nigrescens ATCC $33563^T$-Specific PCR Primers (Prevotella nigrescens ATCC $33563^T$ 균주-특이 중합효소연쇄반응 프라이머 개발)

  • Song, Soo-Keun;Yoo, So-Young;Kim, Mi-Kwang;Kim, Hwa-Sook;Lim, Sun-A;Kim, Do-Kyung;Park, Jae-Yoon;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.212-220
    • /
    • 2008
  • A Pn10 DNA probe was introduced as a Prevotella nigrescens ATCC $33563^T$-specific DNA probe. In that study, the specificity of the Pn10 was tested with only type or reference strains of 5 oral bacterial species. The purpose of this study is to evaluate the specificity of the Pn10 using the wild type strains of P. nigrescens and is to develop the P. nigrescens ATCC $33563^T$-specific PCR primers based on the nucleotide sequence of the Pn10. The specificity of the Pn10 DNA probe was determined by Southern blot analysis. The nucleotide sequence of Pn10 DNA probes was determined by chain termination method. The PCR primers were designed based on the nucleotide sequence of cloned DNA fragment. The data showed that Pn10 DNA probe were hybridized with the genomic DNAs from P. nigrescens ATCC $33563^T$ and KB6. The Pn10 homologous region, KB6-Pn10, of P. nigrescens KB6 was cloned by PCR and sequenced. The Pn10 and KB6-Pn10 DNA fragments were consisted of 1,875 bp and 1,873 bp, respectively. The percent identity of the two was 98.8% and the divergence of them was 0.6%. The two primer sets (Pn10-F-AC/ Pn10-R-AC and Pn10-F-A/ Pn10-R-A), designed base on the nucleotide sequences of Pn10 DNA probe, were specific to the P. nigrescens ATCC $33563^T$. The two PCR primer sets could detect as little as 4 pg of genomic DNA of P. nigrescens ATCC $33563^T$. These results indicate that the two PCR primer sets have proven useful for the identification of P. nigrescens ATCC $33563^T$, especially with regard to the maintenance of the strain.

Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP (T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • In this paper the signal analysis of eddy current test using transmit-receive(T/R) pancake coil of ECT array probe using electromagnetic finite element method(FEM) is performed. For characteristics analysis, the notch defect is used. The depth of defect is 40[%] of steam generator tube thickness, and inside defect and outside defect are used as simulation examples. The signal analysis is performed according to the variation of receive coil position. The receive coil is positioned $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$ of circumferential position of transmit coil. To obtain e electromagnetic characteristics of robes, the governing equation is derived from Maxwell's equations, and the problem is solved using the 3-dimensional finite element method. The signal magnitude of inside defect is bigger than that of outside defect, and the signal difference can be seen according to the variation of position of receive coil. The experimental signal and numerical signal of ASME standard tube show similar results. The results in this paper can be helpful when the ECT signals from ECT array probe are evaluated and analyzed.

Design of Broad Bandwidth Dipole Antenna with CMM Feeding Probe Structure (CMM 급전 구조를 가지는 광대역 다이폴 안테나의 설계)

  • Lee, Ji-Chul;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.1030-1036
    • /
    • 2010
  • This paper proposes a simulation design for feeding probe with the CMM(Cylindrical Magneto Material) structure for broad bandwidth of a dipole type antenna. In order to ensure low frequency bandwidth, the magnetic material with high relative permeability was considered in design calculation. It was confirmed that the broad bandwidth was independent on the relative permeability value and depended on the control of distance($r_m$) between magnetic material and feeding probe, and of magnetic material thickness($t_m$). Furthermore, an antenna size with the CMM was miniaturized about 18 % comparison with its size without the CMM.

Approximation Equation for Broad Bandwidth Antenna Design Using CMMS

  • Min, Kyeong-Sik;Lee, Ji-Chul
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.296-302
    • /
    • 2010
  • This paper proposes an approximate equation for broad bandwidth conditions in an antenna feeding probe design with a cylindrical magneto material structure (CMMS). The bandwidth calculation has been conducted according to the relation between the distance ($r_m$) between the magneto material and feeding probe, and the magneto material thickness ($t_m$) for a given ${\mu}_r$. The bandwidth of a proposed antenna with CMM feeding structure is improved about 182 %, when ${\mu}_r=20+j0.001$, in comparison with the bandwidth of an antenna without CMMS. The maximum error extent between the bandwidth calculated by the approximation equation and by the numerical calculation of the proposed antenna is about $\pm$3.2 % for ${\mu}_r=10+j0.001$. The approximation equation proposed in this study can solve the conventional problem of the complex process and the long time required for reiterative calculation, and allow simple and precise design with prediction. The accuracy of an approximated equation is compared with the results calculated by a commercial tool and verified by reasonable agreement between them.