• Title/Summary/Keyword: SystemC

Search Result 26,440, Processing Time 0.05 seconds

A Study on the Development & Performance Improvement of Vertical Type LPE System for a Ulta Thin Layer Single Crystal Growth (초박막구조 단결정성장을 위한 수직형 LPE장치의 제작과 성능개선에 관한 연구)

  • 오종환;홍창희
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.4
    • /
    • pp.83-92
    • /
    • 1995
  • In this study, a vertical type LPE system has been developed for III-V semiconductor compounds single crystal growth. On the basis of the experience & basic study using this system, the system modification has been carried out for a ultra thin multi-layer single crystal. The temperature fluctuation was within ${\pm}0.006^{\circ}C$ at $800^{\circ}C$, temperature uniformity for graphite boat around was within ${\pm}0.15^{\circ}C$ at $650^{\circ}C$, and cooling rate was controllable from $2.2^{\circ}C$/min to $0.05^{\circ}C$/min. As a result it is considered to satisfy the condition to grow a ultra thin layer single crystal of III-V semiconductor compounds.

  • PDF

Research for Implant system according to investment condition and Bum out temperature (Implant system의 매몰조건과 소환온도에 대한 조사)

  • Park, Geun-Hyeung
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.115-121
    • /
    • 2001
  • This study was investigated on effect of implant system about investment condition and burn out temperature. Posterior bridges were fabricated by using plastic sleeve and gold sylinder. The results were as follows; In plastic sleeve test and fitting cast copings. the phosphate bonded investment showed better gypsum bonded investment. The pure special liquid showed better margin fitness compared with mixed liquid (special liquid + distilled water). In gold cylinder test. the good burn out temperature of Ceramic PFG and Crown Gold was evaluated $0^{\circ}C$ to $820^{\circ}C$ and was decreased on $780^{\circ}C$ for 30 minutes. $0^{\circ}C$ to $750^{\circ}C$ and was decreased on $650^{\circ}C$ for 30 minutes.

  • PDF

Web-Based Score Processing System using C2 Architecture (C2 아키텍처를 이용한 웹 기반 성적처리 시스템)

  • Jeong, Hwa-Young;Kim, Jong-Jin;Kim, Jong-Hoon
    • Journal of The Korean Association of Information Education
    • /
    • v.9 no.1
    • /
    • pp.49-55
    • /
    • 2005
  • Web-Based instruction system embodied according to traditional process until present. But, these method have inefficiency in system development and give trouble of operation and administration after development. Therefore, It need induction of component based development in Web-Based instruction system. In this research, I constructed score processing system by component composition. I embodied component by Java Beans and used C2 architecture at the composition method. In this result, I shown in application possibility of component based development in Web-Based instruction system as to construct whole score processing system through composition of each component.

  • PDF

A Study on Design of TMR Control System for Steam Turbine (터빈 감시제어용 삼중화 제어시스템 설계에 관한 연구)

  • Ahn, Jong-Bo;Kim, Kook-Hun;Kim, Seog-Joo;Kim, Chun-Kyong;Kim, Jong-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.663-665
    • /
    • 2000
  • For the control system of thermal turbine in fuel and nuclear power plant, as high reliability and availability are required, redundant control system is generally applied. This paper presents the configuration and design of such a redundant control system that can be suitable for control and monitoring of the turbine. System components such as I/O system, communication networks, voting system are designed, and especially the new intelligent voter using serial communication are proposed. The characteristics of the implemented control system is independence of the control, protection and monitoring functions, and discrimination of the redundancies, and high availability. The control functions such as speed control, load control, valve control and protective functions such as overspeed and PLU are designed in detail.

  • PDF

A Study on the RF Shower System to Extend Interrogating Range for the Low Power RFID Reader System (저출력 RFID 시스템에서 인식거리 확대를 위한 전력 공급용 RF Shower 시스템)

  • Jung, Jin-Wook;Bae, Jae-Hyun;Oh, Ha-Ryoung;Seong, Yeong-Rak;Song, Ho-Jun;Jang, Byeong-Jun;Choi, Kyung;Lee, Jung-Suk;Lee, Hong-Bae;Lee, Hak-Yong;Kim, Jong-Min;Shin, Jae-Cheol;Park, Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.526-533
    • /
    • 2006
  • In this paper, we presented the synchronization module between RF shower system and RFID Reader to extend interrogating range on Mobile RFID system, Costas Loop and FPLL(Frequency/phase Lock Loop) were used. We achieved compromised range of 3MHz locking frequency, 1ms locking time and figured out remarkable Hopping frequency of the Reader. The prototype of the new designed RFID system has been tested with ISO18000-6 type-B Tag. The read range between designed RFID Reader and Tag has been measured, it increased triple times by adjusting the Shower system output level.

Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Carbon Dioxide (R744) and Propane (R290) (내부 열교환기 부착 $CO_2-C_3H_8$용 캐스케이드 냉동시스템의 성능 특성)

  • Son, Chang-Hyo
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.6
    • /
    • pp.526-533
    • /
    • 2009
  • In this paper, cycle performance analysis of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system with internal heat exchanger is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree and gas cooling pressure and evaporating temperature in the propane (R290) low temperature cycle and the carbon dioxide (R744) high temperature cycle. The main results were summarized as follows : The COP of cascade refrigeration system of $CO_2-C_3H_8$ (R744-R290) increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of cascade refrigeration system increases with the increasing evaporating temperature, but decreases with the increasing gas cooling pressure. Therefore, superheating and subcooling degree, compressor efficiency, evaporating temperature and gas cooling pressure of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system have an effect on the COP of this system.

Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향)

  • Kim, Jung-Cheol;Lee, Kyu-Sun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.

A New Temperature Control System by PWM Control Method for Thermal Massage System (PWM 제어방식에 의한 온열치료기의 새로운 온도제어 시스템)

  • Song, Myoung-Gyu;Lee, Jae-Heung
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.409-419
    • /
    • 2014
  • This paper proposes a new temperature control algorithm and system configuration of the pTMS(personal Thermal Massage System). By controlling the pulse width of the PWM(Pulse Width Modulation), the temparature of the heating lamp can be controlled stably, which is indispensable to the massage function. This technology is also adapted to the 'thermal massage', 'thermal acupressure', 'thermal moxibustion' functions of medical equipments. The temperature could be set at between $40^{\circ}C{\sim}70^{\circ}C$ by increments of $5^{\circ}C$, the control could be made in real time by increments of $1^{\circ}C$, and the temperature is displayed on the monitor by triggering every 2 seconds. when the present temperature is equal to the preset temperature, the PWM signal is minimized, and when the present temperature is higher than the preset temperature, overheating is prevented by interrupting the PWM output signal. When the difference of temperature exceeds $4^{\circ}C$, the PWM control is maximized in order for the system to reach the target temperature within a short period of time.

The Motion of Carbon Plume in Ar Plasmas (Ar 플라즈마 상태에서의 탄소 입자 운동 모델링)

  • So, Soon-Youl;Chung, Hae-Deok;Lee, Jin;Park, Gye-Choon;Kim, Chang-Sun;Moon, Chae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.15-19
    • /
    • 2006
  • A pulsed laser ablation deposition (PLAD) technique is an excellent method for the fabrication of amorphous carbon (a-C) films, because it can generate highly energetic carbon clusters on a substrate. This paper was focused on the understanding and analysis of the motion of C particles in laser ablation assisted by Ar plasmas. The simulation has carried out under the pressure P=50 mTorr of Ar plasmas. Two-dimensional hybrid model consisting of fluid and Monte-Carlo models was developed and three kinds of the ablated particles which are carbon atom (C), ion ($C^+$) and electron were considered in the calculation of particle method. The motions of energetic $C^+$ and C deposited upon the substrate were investigated and compared. The interactions between the ablated particles and Ar gas plasmas were discussed.

  • PDF