• Title/Summary/Keyword: System-rated power

Search Result 366, Processing Time 0.026 seconds

A design of vertical axis wind power generating system combined with Darrieus-Savonius for adaptation of variable wind speed (다변풍속 적응형 Darrieus-Sauonius 초합 수직푹 풍력발전 시스템의 설계)

  • 서영택;오철수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.185-192
    • /
    • 1996
  • This paper presents a design of vertical axis Darrieus wind turbine combine with Savonius for wind-power generating system to be adapted for variable wind speed. The wind turbine consists of two troposkien- and four Savonius-blades. Darrieus turbine is designed with diameter 9.4[m], chord length 380[mm], tip speed ratio 5. Savonius turbine is designed with diameter 1.8[m], height 2[m], tip speed ratio 0.95. The design of turbine is laid for the main data of rated wind speed 10[m/s], turbine speed 101.4[rpm]. The generating power is estimated to maximum power 20[kW], and this is converted to commercial power line by means of three phase synchronous generator-inverter system. Generating system is designed for operation on VSVF(variable speed variable frequency) condition and constant voltage system.

  • PDF

Repetitive Controller for High Power UPS System with Low Switching Frequency (낮은 스위칭 주파수를 갖는 대용량 무정전 전원장치를 위한 반복제어기)

  • Lee, Taeyeong;Cho, Younghoon;KIM, JISU;BYEON, YONGSEOP
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.477-478
    • /
    • 2016
  • This paper introduces a repetitive controller in low switching frequency applications. Generally, A high power UPS system has a high rated current. And the system usually consist of high power IGBT has a tail current. So the high power UPS system operates in low switching frequency because of this tail current. The repetitive controller improve THD of output voltage or current by reducing the steady state error. The effect of the repetitive controller is proved by simulations.

  • PDF

An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

A Study of Safety Acquirement for an Assessment of Ultra High Pressure System (초고압 시스템의 안전성 확보에 대한 연구)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Kim, Jae-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.5
    • /
    • pp.7-14
    • /
    • 2010
  • Ultra high pressure system, which can be generally increased over 1,000bar, needs to have sealing mechanism to protect leakage and selection of the materials used in the intensifier. Components such as pressure vessel, hydraulic hose assembly, accumulator, hydraulic cylinder, hydraulic valve, pipe, etc., are tested under the impulse-pressure conditions. Components need to be tested under 1.5 to 3 times of rated pressure to check the tolerance even though rated pressure range of these components are not ultra high pressure. So, the ultra high pressure system needs to be equiped to test components. In this study, safety assessments of ultra high pressure system which are using failure analysis of components, changing the types of the control system, and finite element analysis with static condition, are investigated.

The Development of Power Conditioning System for 100kW MCFC Systems (100kW급 MCFC용 계통연계형 Power Conditioning System 개발)

  • Jung, Hong-Ju;Kwon, Hyoung-Nam;Chung, Joon-Mo;Suh, In-Young;Lim, Hee-Cheon;Ahn, Kyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1784-1787
    • /
    • 2005
  • This paper presents the development and testing of a power conditioning system(PCS) for application to a 100kW Molten Carbonate Fuel Cell(MCFC) generation system. The MCFC generation system is a part of a four year government funded research project that began in 2001. This paper presents the results of various tests and performance verification of the 100kW PCS using a DC power system that simulates the DC output of the MCFC fuel cell. Performance of the DC/DC, DC/AC converters were verified, and basic control functions such as grid connection, protection and characteristics of each components were tested. The tests were performed under light load and rated load conditions to verify the operation efficiency, power quality effects, and stability of the PCS.

  • PDF

Development of Turbo Expanders with Hydrostatic Bearings for Hydrogen Liquefaction Plants (정압 베어링을 적용한 수소 액화 공정용 터보 팽창기 개발)

  • Lee, Donghyun;Kim, Byungock;Park, Mooryong;Lim, Hyungsoo
    • Tribology and Lubricants
    • /
    • v.37 no.3
    • /
    • pp.91-98
    • /
    • 2021
  • This paper presents a hydrostatic bearing design and rotordynamic analysis of a turbo expander for a hydrogen liquefaction plant. Th~e turbo expander includes the turbine and compressor wheel assembled to a shaft supported by two hydrostatic radial and thrust bearings. The rated speed is 75,000 rpm and the rated power is 6 kW. For the bearing operation, we use pressurized air at 8.5 bar as the lubricant that is supplied to the bearing through the orifice restrictor. We calculate the bearing stiffness and flow rate for various gauge pressure ratios and select the orifice diameter providing the maximum bearing stiffness. Additionally, we conduct a rotordynamic analysis based on the calculated bearing stiffness and damping considering design parameters of the turbo expander. The predicted Cambell diagram indicates that there are two critical speeds under the rated speed and there exists a sufficient separation margin for the rated speed. In addition, the predicted rotor vibration is under 1 ㎛ at the rated speed. We conduct the operating test of the turbo expander in the test rig. For the operation, we supply pressurized air to the turbine and monitor the shaft vibration during the test. The test results show that there are two critical speeds under the rated speed, and the shaft vibration is controlled under 2.5 ㎛.

Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker (2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구)

  • Oh, SeungRyle;Han, Kisun;Kim, TaeKyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • Recently, the circuit-breaker rated voltage is getting higher as the transmission voltage increases. To increase the circuit-breaker rated voltage, a multi-break circuit-breaker which has two or more breakers in series is adopted. For multi-break circuit-breaker, a grading capacitor is used to mitigate the Transient Recovery Voltage(TRV) and control the voltage distribution across the individual interrupter units. However, all over the world, there are many failures such as mechanical damage, explosion due to insulation breakdown. Therefore, it is necessary to study the causes of failure and the new performance verification method. In this paper, we investigate the causes of dielectric breakdown of the grading capacitors in the KEPCO power system and propose the performance verification method.

The Comparison of PWM Converter's Topology in Electric Train (철도차량용 PWM 컨버터방식 비교)

  • 이현원;김남해
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.97-100
    • /
    • 1999
  • AC to DC single phase PWM converter for traction application requires rated high power and voltage. Therefor, series or parallel operation converters are necessary with considering the limitation of the power device specification. This paper compares the characteristic between two parallel operation of conventional PWM converter and Single phase three level converter about comparison of power circuit, cooling system control method and harmonic current by computer simulation.

  • PDF

A Study on Multi-level Converter Based on Distribution Active Hybrid Solid State Transformer (멀티레벨 컨버터 기반 배전용 능동형 하이브리드 반도체 변압기에 대한 연구)

  • Yun, Chun-gi;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.84-86
    • /
    • 2018
  • Active hybrid solid state transformer(AHSST) is newly emerging as a device to maintan the power quality of power distribution. AHSST has a simple structure in which a power electronics device is connected in series to a conventional distribution transformer. The connected power electronics device maintains the constant voltage regardless of the primary grid voltage fluctuation through the secondary voltage control to improve the power quality. It also has a simple structure compare to conventional solid state transformer system and can achieve the same performance with fractionally-rated converter. This paper proposes an multi-level converter based on AHSST system that has a simpler control method and wider voltage control range than the conventional AHSST. The proposed system is verified by simulations.

  • PDF

Gird-interactive Current Controlled Voltage Source Inverter System with UPS (UPS를 고려한 계통연계 전류제어형 전압원 인버터)

  • Ko, Sung-Hun;Lim, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.