• 제목/요약/키워드: System of Circulation

검색결과 1,701건 처리시간 0.036초

저층수 흡입식 광역 순환장치의 설계변수에 따른 배출량 및 소비동력 변화 특성에 대한 수치 해석 연구 (Numerical Analysis on Changes in Flowrate of Draft Water and Power by Changing Design Parameters of a Long-Distance Water Circulation)

  • 송동근;홍원석;김영철;박명하
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.23-28
    • /
    • 2010
  • A draft tube which has impeller to elevate bottom water and spread it over surface of lake water, induces convective circulation of lake water, a Long-Distance Circulation (LDC). Circulation of lake water make stratified water mixed and enhance DO (Dissolved Oxygen) of bottom water. Circulation rate of water is determined by draft rate of the tube, which is dependent on design parameters of the draft tube system, i. e. dimension of impeller and diffuser, inclined angle of impeller, impeller shape, and rotational speed. In this study, change in draft rate and power consumption of circulation equipment was investigated numerically with changing impeller dimension, angle and rotational speed. It was found that flowrate of draft water was increased as the dimensions of draft tube and impeller, and rotational speed and inclined angle of impeller increased. The power consumption was also elevated with increasing parameter values, and final selection of parameter values was made to satisfy target flowrates and power consumption.

Numerical simulation of a toroidal single-phase natural circulation loop with a k-kL-ω transitional turbulence model

  • Yiwa Geng;Xiongbin Liu;Xiaotian Li;Yajun Zhang
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.233-240
    • /
    • 2024
  • The wall friction correlations of oscillatory natural circulation loops are highly loop-specific, making it difficult to perform 1-D system simulations before obtaining specific experimental data. To better predict the friction characteristics, the nonlinear dynamics of a toroidal single-phase natural circulation loop were numerically investigated, and the transition effect was considered. The k-kL-ω transitional turbulence and k-ω SST turbulence models were used to compute the flow characteristics of the loop under different heating powers varying from 0.48 to 1.0 W/cm2, and the results of both models were compared with previous experiments. The mass flow rates and friction factors predicted by the k-kL-ω model showed a better agreement with the experimental data than the results of the k-ω SST model. The oscillation frequencies calculated using both models agreed well with the experimental data. The k-kL-ω transitional turbulence model provided better friction-factor predictions in oscillatory natural circulation loops because it can reproduce the temporal and spatial variation of the wall shear stress more accurately by capturing the movement of laminar, transition turbulent zones inside unstable natural circulation loops. This study shows that transition effects are a possible explanation for the highly loop-specific friction correlations observed in various oscillatory natural circulation loops.

대학도서관 이용조사를 통한 경영개선 연구 - C 대학도서관 이용자의 대출기록 분석을 중심으로- (A Management Improvement Study by the Use Survey of an Academic Library - Focused on the Analysis of Circulation Records of the C-Academic Library Users -)

  • 유경종;박일종
    • 정보관리학회지
    • /
    • 제24권3호
    • /
    • pp.93-117
    • /
    • 2007
  • 본 논문은 C대학도서관의 학술정보시스템(LAS)에 구축되어 있는 장서와 대출기록 및 고객관련 데이터를 수집하여 이를 분석하고 그 결과를 고객관계관리(CRM)에 적용할 수 있는 방안을 제시하였다. 수집된 자료는 C대학도서관에서 소장하고 있는 대출이 가능한 단행본 총 269,387책의 서지데이타와 고객 12,281명의 데이터, 이용자 대출기록 39,269건이었다. 대출기록 분석 데이터에서 관계변수로 이용자 신분, 대출빈도, 대출책수와 대출횟수, 출판년도를 추출하여 데이터 마이닝 기법으로 분석하고, 상관계수로 검증하였다.

Experimental and numerical investigations on effect of reverse flow on transient from forced circulation to natural circulation

  • Li, Mingrui;Chen, Wenzhen;Hao, Jianli;Li, Weitong
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.1955-1962
    • /
    • 2020
  • In a sudden shutdown of primary pump or coolant loss accident in a marine nuclear power plant, the primary flow decreases rapidly in a transition process from forced circulation (FC) to natural circulation (NC), and the lower flow enters the steam generator (SG) causing reverse flow in the U-tube. This can significantly compromise the safety of nuclear power plants. Based on the marine natural circulation steam generator (NCSG), an experimental loop is constructed to study the characteristics of reverse flow under middle-temperature and middle-pressure conditions. The transition from FC to NC is simulated experimentally, and the characteristics of SG reverse flow are studied. On this basis, the experimental loop is numerically modeled using RELAP5/MOD3.3 code for system analysis, and the accuracy of the model is verified according to the experimental data. The influence of the flow variation rate on the reverse flow phenomenon and flow distribution is investigated. The experimental and numerical results show that in comparison with the case of adjusting the mass flow discontinuously, the number of reverse flow tubes increases significantly during the transition from FC to NC, and the reverse flow has a more severe impact on the operating characteristics of the SG. With the increase of flow variation rate, the reverse flow is less likely to occur. The mass flow in the reverse flow U-tubes increases at first and then decreases. When the system is approximately stable, the reverse flow is slightly lower than obverse flow in the same U-tube, while the flow in the obverse flow U-tube increases.

습식 마늘박피 시스템 개발 (III) - 미생물 제어 시스템의 도입 - (Development of a Garlic Peeling System Using High-Pressure Water Jets (III) - Introduction of a microbial control system -)

  • 김정호;배영환
    • Journal of Biosystems Engineering
    • /
    • 제30권1호
    • /
    • pp.17-24
    • /
    • 2005
  • An efficient microbial control system was introduced into a garlic peeling system using pressurized water in order to improve the quality and the shelf-life of peeled garlic. High microbial density of the spoiled peeled garlic and the water used for peeling and washing indicated that an efficient microbial control system is necessary far the peeling system. Though Pseudomonas spp. and Penicillium spp. were closely related to the spoilage of peeled garlic, the spoilage of peeled garlic was thought to be caused mainly by nonspecific increase in microbial density. The shelf-life of the garlic peeled by pressurized water was longer than that of the garlic peeled by pressurized air, and the degree of damage had great effect on the shelf-life of peeled garlic. Ozonated water was effective in decreasing the microbial contamination and in increasing the shelf-life of peeled garlic. Based on the findings of the study, following improvements were made to the garlic peeling system using pressurized water; 1) the water circulation system was modified in order to completely separate the water for washing from the water for garlic peeling, 2) filtration and cooling equipments were introduced into the circulation system of the water for peeling, and 3) an ozone generator which could continuously supply ozonated water (dissolved ozone concentration of 0.4 ppm) was attached to the circulation system of the water for washing.

전차선로 전기적 특성 평가 시스템 구현 (Implementation of Electrical Property Assessment System for Overhead Contact Lines)

  • 오석용;박영;조용현;이기원;송준태
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.497-503
    • /
    • 2011
  • Currently in Korea, the simple catenary type overhead contact line system is being applied to both conventional lines and high speed lines of electric railway, and circulation current flowing into the catenary system frequently bring undesirable consequences. Namely, the connector wire has many problems according to a flow of excessive circulation current and arc current on catenary when an electric train runs at high speed. This paper presents the development and application of a real-time data acquisition system designed to measure the electrical characteristics of an overhead catenary system in electric railways. The developed system is capable of storing data of a 25 kV power source in a live wire state through a telemetry environment. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of current of an overhead catenary system.

단순화된 피동 원자로건물 냉각계통 내 자연순환에 관한 수치적 연구 (Numerical Investigation on Natural Circulation in a Simplified Passive Containment Cooling System)

  • 서정수
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.92-98
    • /
    • 2018
  • The flow of cooling water in a passive containment cooling system (PCCS), used to remove heat released in design basis accidents from a concrete containment of light water nuclear power plant, was conducted in order to investigate the thermo-fluid equilibrium among many parallel tubes of PCCS. Numerical simulations of the subcooled boiling flow within a coolant loop of a PCCS, which will be installed in innovative pressurized-water reactor (PWR), were conducted using the commercially available computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the RPI model were used for turbulence closure and subcooled flow boiling, respectively. As the first step, the simplified geometry of PCCS with 36 tubes was modeled in order to reduce computational resource. Even and uneven thermal loading conditions were applied at the outer walls of parallel tubes for the simulation of the coolant flow in the PCCS at the initial phase of accident. It was observed that the natural circulation maintained in single-phase for all even and uneven thermal loading cases. For uneven thermal loading cases, coolant velocity in each tube were increased according to the applied heat flux. However, the flows were mixed well in the header and natural circulation of the whole cooling loop was not affected by uneven thermal loading significantly.

Prediction of shiver differentiation by the form alteration on the stable condition

  • Kim, Jeong-lae;Kim, Kyu-dong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제9권4호
    • /
    • pp.8-13
    • /
    • 2017
  • Movement technique is comprised of the movement status of the circulation differentiation rate (CDR) and rotation differentiation rate (RDR) on the shiver movement form. Condition of the differentiation rate by the shiver movement form is to be modified the teetering movement system. As to fix the movement of signal on the material of body, we compared a shiver value of the circulation differentiation rate on the circulation state. The concept of rotation differentiation rate was identified the reference of rotation differentiation signal and rotation differentiation signal by the rotation state. For detecting a alteration of the CDR-RDR of the maximum and average in terms of the movement form, and shiver movement value that was a shiver value of the top alteration of the Top-ф$_{MAX-AVG}$ with $12.80{\pm}1.27units$, that was a shiver value of the peripheral alteration of the Per-ф$_{MAX-AVG}$ with $4.38{\pm}1.15units$, that was a shiver value of the limbus alteration of the Lim-ф$_{MAX-AVG}$ with $1.65{\pm}0.25units$, that was a shiver value of the center alteration of the Cen-ф$_{MAX-AVG}$ with $0.25{\pm}0.01units$. The teetering movement will be to assess at the ability of the movement form for the control degree of differentiation rate on the CDR-RDR that was shown the circulation and rotation form by the differentiation rate system. Teetering differentiation system was modified of a form by the special movement and was included a shiver data of teetering movement rate.

An Implementation of DAQ and Monitoring System for a Smart Fish Farm Using Circulation Filtration System

  • Jeon, Joo Hyeon;Lee, Na Eun;Lee, Yoon Ho;Jang, Jea Moon;Joo, Moon Gab;Yoo, Byung Hwa;Yu, Jae Do
    • Journal of Information Processing Systems
    • /
    • 제17권6호
    • /
    • pp.1179-1190
    • /
    • 2021
  • A data acquisition and monitoring system was developed for an automated system of a smart fish farm. The fish farm is located in Jang Hang, South Korea, and was designed as circulation filtration system. Information of every aquaculture pool was automatically measured by pH sensors, dissolved oxygen sensors, and water temperature sensors and the data were stored in the database in a remoted server. Modbus protocol was used for gathering the data which were further used to optimize the pool water quality to predict the rate of growth and death of fish, and to deliver food automatically as planned by the fish farmer. By using JSON protocol, the collected data was delivered to the user's PC and mobile phone for analysis and easy monitoring. The developed monitoring system allowed the fish farmers to improve fish productivity and maximize profits.

자연순환식 태양열 급탕 시스템의 성능 추정 방법에 관한 연구 (A Study on the System Performance Prediction Method of Natural Circulation Solar Hot Water System)

  • 윤석범;전문헌
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.37-53
    • /
    • 1987
  • This study has been prepared for the purpose of developing the system performance prediction method of natural circulation solar hot water system. The storage tank of the natural circulation solar hot water system equipped with flat-plate solar collector is located at higher elevation than the solar collectors. Therefor, the storage tank temperature distribution formed accordance with configuration of storage tank by flow rate of circulating fluid affect system collection efficiency. In this study measure the storage tank temperature distribution with various experimental system under real sun condition and present the theoretical prediction method of the storage tank temperature. Moreover measure the flow rate not only day-time but also night-time reverse flow rate with die injection visual flow meter. Main conclusion obtain from the present study is as follows; 1) The storage tank temperature distribution above the connecting pipe connection position is the same as that of the fully mixed tank and below the connection position is the same as that of stratified tank. 2) The system performance sensitive to the storage tank temperature distribution. Therefore detailed tank model is necessary. Average storage tank temperature can be calculate 3% and storage tank temperature profile can get less than 10% difference with this model system.

  • PDF