• Title/Summary/Keyword: System Capacity

Search Result 8,692, Processing Time 0.038 seconds

Wideband DS/CDMA system capacity analysis impacted by the man-made noise and imperfect sectorization (불완전 섹터화 및 인공잡음의 영향에 의한 광대역 DS/CDMA시스템의 용량 분석)

  • Kim, Hae-Ki;Kim, Nam
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.65-68
    • /
    • 1999
  • In this paper the Wideband DS/CDMA system capacity variation is analyzed by the impact of imperfect sectorization and man-made noise, which is more predominant in urban area than thermal noise. In general man-made noise is increasing as the electronic machines are increasing nowadays. It shows that user capacity and cell radius variation are much sensitive by the man-made noise.

  • PDF

The Cooling Effect of PAD Location and FAN Capacity on Greenhouse (PAD 위치 및 FAN 용량에 따른 온실의 냉방효과)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.399-404
    • /
    • 1999
  • This study were performed to find the cooling effect and to provide design data during summer season for the Pad& Fan system of greenhouse . The temperature variation along the greenhouse width were analyzed. Also, the effect of the pad location and fan capacity on the cooling of the greenhouse were analyzed. While Pad &Fan systems were operating the temperatures in greenhouse were very different along the meausring locations. It is recommeded that PAD location and FAN capacity should be considered to design the Fan and Pad system in order to provide greenhouse the optimum temperature condition.

  • PDF

Generativity Capacity: Conceptual Definition and Determinants (제너러티비티역량 : 개념적 정의 및 결정요인)

  • Yoon, Jihyun;Kwahk, Kee-Young
    • Knowledge Management Research
    • /
    • v.15 no.3
    • /
    • pp.95-120
    • /
    • 2014
  • In order to successfully adapt in ever-changing social and economic environment, organizational members need to get a capacity to be open to accepting change, effectively leverage the knowledge assets accumulated inside and outside the company for pursuing new values. In this study, we defined such competence as generativity capacity and demonstrated mechanism for forming generativity capacity and an impact on job performance. We suggested absorptive capacity, tertius iungens orientation, use of information technology as antecedent variables of generativity capacity. For empirically verifying the proposed model, we collected sample data from 201 workers and conducted analysis using a structural equation modeling. The empirical analysis results revealed that all of the proposed antecedent variables significantly impacted on generativity capacity, which in turn had a significant effect on job performance. We expect that this study will provide researchers and managers who want to get a broader perspective on knowledge management beyond the boundaries with useful theoretical and practical implications.

  • PDF

Analysis of Line Capacity for the Special Structure in Railway (특이구조를 갖는 선로구간의 용량분석에 관한 연구)

  • Kim Dong-Hee;Hong Soon-Heum
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.668-673
    • /
    • 2003
  • Line Capacity is a criteria for transport capacity and is used to evaluate railroad investment alternatives or to decide train frequency when establish transportation plan. There are two methodologies to increase transport capacity of railway. One is to invest railroad equipment or vehicles, and the other is to improve operation efficiency through optimization. Such all efforts are intended to increase transport capacity by improving line capacity. So far, this criteria is calculated statical and experimental numerical formula. But, line capacity has special attribute that changes dynamically according to operational conditions, so there is a need of new line capacity estimation system. In this paper, we present a new estimation method of line capacity based on the probability simulation, and apply to normal railline section and special structured railine section.

  • PDF

Capacity Expansion Planning Model of Private Distribution Center Under Usability of Public Distribution Center (영업용 물류센터 사용하에서 자가 물류센터의 크기 확장계획 모형)

  • Chang, Suk-Hwa
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.1
    • /
    • pp.71-79
    • /
    • 2010
  • This paper addresses capacity expansion planning model of distribution center under usability of public distribution center. For discrete and finite time periods, demands for distribution center increase dynamically. The capacity expansion planning is to determine the capacity expansion size of private distribution center and usage size of public distribution center for each period through the time periods. The capacity expansion of private distribution center or lease usage of public distribution center must be done to satisfy demand increase for distribution center. The costs are capacity expansion cost and excess capacity holding cost of private distribution center, lease usage cost of public distribution center. Capacity expansion planning of minimizing the total costs is mathematically modelled. The properties of optimal solution are characterized and a dynamic programming algorithm is developed. A numerical example is shown to explain the problem.

Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods (대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

Performance Analysis of an Intelligent Peripheral System in Advanced Intelligent Network (시뮬레이션을 통한 AIN IP 시스템의 호처리용량 분석)

  • Suh, Jae-Joon;Choi, Go-Bang;Yeo, Kun-Min;Jun, Chi-Hyuck
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.77-87
    • /
    • 1998
  • Intelligent Peripheral(IP) system is to provide specialized resource functions (SRF) such as playing announcement, collecting user information, and receiving messages in the Advanced Intelligent Network (AIN). We analyze the call processing capacity of an AIN IP system being developed in ETRI through an extensive simulation using SLAM II under a variety of AIN service scenarios. We consider televoting (VOT) and universal personal telecommunication (UPT) services which are to be provided at the fit implementation of the AIN in Korea. As the performance criteria to determine the call processing capacity, processor utilization, delay and call loss probability are considered. It turns out that the major processor called SAMP is the bottleneck processor, the service response delay dominates the delay performance, and the call loss probability becomes the primary criterion in determining the call processing capacity of the AIN IP system. It is also shown that the call processing capacity of the AIN IP system is determined by the utilization of the processor and the delay performance when the VOT ratio is below 70 percent but it is determined by the call loss probability due to the lack of service channels for providing the SRF operations.

  • PDF

Power Control Based Call Admission Control Method of the CDMA PCS System

  • 이강원;국광호;최정락
    • Korean Management Science Review
    • /
    • v.16 no.1
    • /
    • pp.39-50
    • /
    • 1999
  • This paper proposes a new call admission control method to enhance the reverse link capacity of a cell with heavy traffic in the CDMA PCS system under the uneven traffic load between cells. Since the capacity of a cell in the CDMA system is restricted by the total interference caused by terminals in the own cell and the adjacent cells, we can enhance the capacity of a cell by reducing the interference from other cells if possible. Our power control method allows that the signal powers received in base stations with heavy traffic be larger than those received in base stations with light traffic in order to make the interference due to other cells in the cells with heavy traffic relatively small. In the previous study, it was assumed that the signal power received by each base station in the CDMA PCS system is same when the call admission control algorithm is implemented. We could show that the reverse link capacity of a cell in the CDMA PCS system can be increased about 20% under our call admission control method.

  • PDF

An Analysis of Various Factors that Determines the Size of Electric Room(22.9Kv class) (전기실의 면적을 결정하는 제 요소의 분석(22.9Kv class))

  • Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.443-445
    • /
    • 2001
  • As the new large buildings are continuously being built with the advanced technology and skills, an adequate size of electric room needs to be obtained so that engineers establish an efficient and reliable system in the electric room. Considering the current capacity, its expansion and its connecting system, the final size of it should be determined in order to bring an effective use of the building. Usually the extension of electricity capacity is on the increase after construction and it comes from the lack of scientific evaluation on the electric room. Later when the expansion of computer and important electric equipment that needs much capacity is impossible, it will cause a great deal of damage to the renting business of the building as well as becomes the unstable factors of the whole system. Therefore, it is important to have the exact method of calculating the effective size of electric room, the heart of the building, especially when the value of land price is very high. In addition, it should be calculated in an accurate way due to the diversification of the system and the compact size of the electricity equipment. However, the research on this area and the comparison and evaluation of the size after construction have not been made enough and the results of them have not been applied when calculating a new size of electric room. Accordingly, this study examines three methods prescribed in the standards of electricity installation technology through case analysis and suggests substantial data by system, capacity, and purpose.

  • PDF

A Study on Sizing of Battery for Effective Operation of Stand-alone Renewable Generation System (독립형 신재생발전 시스템의 효율적인 운영을 위한 배터리 용량산정에 관한 연구)

  • Shin, Hee-Sang;Hue, Jae-Sun;Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • This paper presents the method of ESS energy capacity calculation for stand-alone renewable energy generation system consisting of photovoltaic energy. There is almost no power from photovoltaic system during sunless days. So this source is very weak in terms of the power supply reliability. To improve problem of power supply, battery is mainly used Energy Storage System(ESS). The number of sunless days and Depth of Discharge(DOD) is important factor to determine energy capacity of battery. However, a many study for economical design is required due to the high cost of ESS. In this paper, we propose the new method of ESS energy capacity calculation by applying different DOD for operation with and without sun. We determine the Battery capacity using higher DOD of operation during sunless day than the DOD of the normal operation. And we carried out an economic analysis of the calculation results.