• Title/Summary/Keyword: System Base

Search Result 7,078, Processing Time 0.035 seconds

MR Evaluation of Tendinous Portions in the Subscapularis Muscle (견갑하근의 건 부분에 대한 자기공명영상을 이용한 분석)

  • Shon, Min-Soo;Koh, Kyoung-Hwan;Lee, Sung-Sahn;Yoo, Jae-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.35-45
    • /
    • 2011
  • Purpose: The purpose of this study was to document the structural features of the tendinous portions within the non-pathologic subscapularis muscle by performing high resolution MR imaging of the shoulder. Materials and Methods: Between April 2007 and May 2010, we retrospectively obtained the MR scans of 88 consecutive young patients (88 shoulders) who were in their twenties. MRI and MR arthrography were performed using a 3.0-T system for the evaluation of glenohumeral instability and nonspecific shoulder pain. None of the patient in this study had any evidence of injury to the tendon or muscle belly of the subscapularis. On MR images, we recorded the transverse length of a stout tendinous band and the total tendinous portion of the subscapularis. In addition, we recorded the number of intramuscular tendinous slips of the susbscapularis. Results: The mean transverse length of the tendinous band was 15.0 mm (range: 8 to 20 mm). The mean transverse length of the total tendinous portion was 48.9 mm (range: 40 to 60 mm). The number of intramuscular tendinous slips on the base of the glenoid fossa was 3 in 20 (22.72%), 4 in 45 (51.14%) and 5 in 23 shoulders (26.14%). On the lateral portion, the intramuscular tendinous slips became gradually rounder and thicker and they gave converge in the superior direction. Conclusion: In this study, the structural features of the tendinous portions of the subscapularis on the MR scans were identified. This will in return give good justification for the lines to be pulled during biomechanical stimulation and also for the surgical approach to restore the biomechanical function.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Alteration of Apurinic/Apyrimidinic Endonuclease-1/Redox Factor-1 in Human Mon-small Cell Lung Cancer (비소세포 폐암조직에시 Apurinic/Apyrimidinic Endonuclease-1/Redox Factor-1의 발현변화)

  • Yoo, Dae-Goon;Song, Yun-Jeong;Cho, Eun-Jung;Kang, Min-Woong;Han, Jong-Hee;Na, Myung-Hoon;Lim, Seung-Pyung;Yu, Jae-Hyeon;Jeon, Byeong-Hwa;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.529-535
    • /
    • 2007
  • Background: An imbalance between oxidants and antioxidants leads to oxidative stress, and this has been proposed to play an important role in the pathogenesis of lung neoplasm. Apurinic/apyrimidinic endonuclease-1/redox factor-1 (APE/ref-1) is a multifunctional protein involved in DNA base excision repair and the redox regulation of many transcription factors. However, the alteration of the expressed levels of APE/ref-1 in non-small cell lung cancer is unknown. Material and Method: Forty-nine patients with surgically resected non-small cell lung cancer (NSCLC) were included in this study. Immunohistochemical staining with APE/ref-1 antibodies was performed, and their expressions were analyzed via Western blotting for specific antibodies. Result: APE/ref-1 was localized at the nucleus and mainly in the non-tumor region of the NSCLC tissue specimens; it was expressed in the cytoplasm and nucleus of the NSCLC. The nuclear and cytoplasmic expressions of APE/ref-1 in lung cancers were markedly up-regulated in the NSCLC, and this was correlated with the clinical stage. Catalase, as first-line antioxidant defense, was dramatically decreased in the NSCLC. Conclusion: Taken together, our results suggest that APE/ref-1, and especially cytoplasmic APE/ref-1, was upregulated in the lung cancer regions, and this may contribute to the compensatory defense system against oxidative stress. A low expression of catalase might have fundamental effects on the extracellular redox state of lung tumors, along with the potential consequences for the tumors.

Location Analysis of A Collective Consumption Facility with GIS: The Location of Gu-Office and Its Administrative District in Ulsan, South Korea (GIS기법을 이용한 도시공공서비스 시설의 입지분석 -울산시 구 관할구역과 구청입지를 중심으로-)

  • Cho, Sung-Ho;Park, Soon-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.2 no.1
    • /
    • pp.69-85
    • /
    • 1996
  • This research adoptes a spatial analysis function of the Geographic Information System[GIS] to analyze the location and the service district of a collective consumption facility, to discover the optimal location, and to redefine the service district. The location and spatial district of a collective consumption facility strongly influences the quality of life of residents. This research studies administrative offices and districts, especially Gu-offices in Ulsan. Ulsan would be raised to the status of Kwangyokshi in 1997; so that, the status of four Gus would be changed from a general administration into a self-governing administration. The summary of this research focuses on five significant points. First, the districts of four Gus were strongly required to be redefined to obtain the maximization of the degree of potential development as well as of the efficiency and equity of administring services. The spatial range of residents in a Gu was not in accord with its administrative district. The administrative districts of four Gus in Ulsan were not balanced in terms of area and population, and the high degree of disparity among Gus existed the efficiency and equality of a collective consumption service. Second, the current gu-offices were located based on security of land and accessibility of a main route; so, there was difficult to find the creteria and the principles of selections of the location of Gu offices. The social disparity of an administrative service existed in the accessibility into Gu-offices. Third, the administrative districts of Gus were redefined with spatial analysis tool of ARC/INFO. It was recommended that Ulsan maintain four Gus under the condition of five Kwangyokshi in South Korea. The redefined districts of administration reduced the disparity among four Gus in terms of area and population. improved the degree of harmony between the spatial range of residents of Gus and the administrative district of Gus, and increased the efficiency and equity of administrative service. Fourth, within the redefined adminis trative district of a Gu, the centroid reduced the maximum distance and mean distance; so, the efficiency and equity of public service provided by the Gu-office were improved. Last, the spatial analysis function of GIS helped to select the optimal location and to delineate the district of public service with more speedly and objectively. The function of spatial analysis of GIS was very useful to minimize the conflict in the determination of the location of a collective consumption facility and of the service district. To improve location analysis with GIS. non-spatial data base such as budget, thought of residents, and development policy and program, should be constructed.

  • PDF

The Origin and Evolution of the Mesozoic Ore-forming Fluids in South Korea: Their Genetic Implications (남한의 중생대 광화유체의 기원과 진화특성: 광상 성인과의 관계)

  • Choi, Seon-Gyu;Pak, Sang-Joon
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.517-535
    • /
    • 2007
  • Two distinctive Mesozoic hydrothermal systems occurred in South Korea: the Jurassic/Early Cretaceous(ca. $200{\sim}130$ Ma) deep-level ones during the Daebo orogeny and the Late Cretaceous/Tertiary(ca. $110{\sim}45$ Ma) shallow hydrothermal ones during the Bulgugsa event. The Mesozoic hydrothermal system and the metallic mineralization in the Korean Peninsula document a close spatial and temporal relationship with syn- to post-tectonic magmatism. The calculated ${\delta}^{18}O_{H2O}$ values of the ore-forming fluids from the Mesozoic metallic mineral deposits show limited range for the Jurassic ones but variable range for the Late Cretaceous ones. The orogenic mineral deposits were formed at relatively high temperatures and deep-crustal levels. The mineralizing fluids that were responsible for the formation of theses deposits are characterized by the reasonably homogeneous and similar ranges of ${\delta}^{18}O_{H2O}$ values. This implies that the ore-forming fluids were principally derived from spatially associated Jurassic granitoids and related pegmatite. On the contrary, the Late Cretaceous ferroalloy, base-metal and precious-metal deposits in the Taebaeksan, Okcheon and Gyeongsang basins occurred as vein, replacement, breccia-pipe, porphyry-style and skarn deposits. Diverse mineralization styles represent a spatial and temporal distinction between the proximal environment of subvolcanic activity and the distal to transitional condition derived from volcanic environments. The Cu(-Au) or Fe-Mo-W deposits are proximal to a magmatic source, whereas the polymetallic or the precious-metal deposits are more distal to transitional. On the basis of the overall ${\delta}^{18}O_{H2O}$ values of various ore deposits in these areas, it can be briefed that the ore fluids show very extensive oxygen isotope exchange with country rocks, though the ${\delta}D_{H2O}$ values are relatively homogeneous and similarly restricted.

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

Population Structure and Fine-scale Habitat Affinity of Cymbidium kanran Protected Area as a Natural Monument (천연기념물 한란 보호구역의 개체군 구조 및 미세 서식처 선호성)

  • Shin, Jae-Kwon;Koo, Bon-Youl;Kim, Han-Gyeoul;Kwon, He-Jin;Son, Sung-Won;Lee, Jong-Seok;Cho, Hyun-Je;Bae, Kwan-Ho;Cho, Young-Chan
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.176-185
    • /
    • 2014
  • There are no population ecological research on the natural monument (No. 191) Jeju Cymbidium kanran in South Korea. In this study, we analyzed the population structure and fine-scale habitat affinity of C. kanran in Sanghyo-dong, Jejudo Island from Oct. 2013 to Feb. 2014. We observed total of 1,237 individuals (4,341 pseudobulbs) of C. kanran (989.6 population $ha^{-1}$) within (1.25 ha) and only 17 (1.4%) individuals were inflorescent. In 60.9% of the entire populations, disease symptoms such as spots and blight leaves were observed. C. kanran populaton exhibited reverse-J shaped size distribution based on leaf area classes as individual size parameter. The three size related attributes of C. kanran (no. of pseudobulb $r_s$=-0.159, no. of leaves $r_s$=-0.148 and leaf arera $r_s$=-0.114) and soil temperature revealed a negative relationship (p<0.0001). Most of C. kanran (95.4%) were grown under Castamopsis cuspidata and spatially, C. kanran were strongly clumped at all distances. Population characteristics of C. kanran in the study area were likely originated from species habitat affinity and successional environment. Through this study, base line data for C. kanran's habitat monitoring was established and conservation measures based on population characteristics were discussed.

Discussions about Expanded Fests of Cartoons and Multimedia Comics as Visual Culture: With a Focus on New Technologies (비주얼 컬처로서 만화영상의 확장된 장(場, fest)에 대한 논의: 뉴 테크놀로지를 중심으로)

  • Lee, Hwa-Ja;Kim, Se-Jong
    • Cartoon and Animation Studies
    • /
    • s.28
    • /
    • pp.1-25
    • /
    • 2012
  • The rapid digitalization across all aspects of society since 1990 led to the digitalization of cartoons. As the medium of cartoons moved from paper to the web, a powerful visual culture emerged. An encounter between cartoons and multimedia technologies has helped cartoons evolve into a video culture. Today cartoons are no longer literate culture. It is critical to pay attention to cartoons as an "expanded fest" and as visual and video culture with much broader significance. In this paper, the investigator set out to diagnose the current position of cartoons changing in the rapidly changing digital age and talk about future directions that they should pursue. Thus she discussed cases of changes from 1990 when colleges began to provide specialized education for cartoons and animation to the present day when cartoon and Multimedia Comics fests exist in addition to the digitalization of cartoons. The encounter between new technologies and cartoons broke down the conventional forms of cartoons. The massive appearance of artists that made active use of new technologies in their works, in particular, has facilitated changes to the content and forms of cartoons and the expansion of character uses. The development of high technologies extends influence to the roles of appreciators beyond the artists' works. Today readers voice their opinions about works actively, build a fan base, promote the works and artists they favor, and help them rise to stardom. As artist groups of various genres were formed, the possibilities of new stories and texts and the appearance of diverse styles and world views have expanded the essence of cartoon texts and the overall cartoon system of cartoon culture, industry, education, institution, and technology. It is expected that cartoons and Multimedia Comics will continue to make a contribution as a messenger to reflect the next generation of culture, mediate it, and communicate with it. Today there is no longer a distinction between print and video cartoons. Cartoons will expand in every field through a wide range of forms and styles, given the current situations involving installation concept cartoons, blockbuster digital videos, fancy items, and characters at theme parks based on a narrative. It is therefore necessary to diversify cartoon and Multimedia Comics education in diverse ways. Today educators are faced with a task to bring up future generations of talents who are capable of leading the culture of overall senses based on literate and video culture by incorporating humanities, social studies, and new technology education into their creative artistic abilities.

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

The Effect of Wedding Industry Employees Exchange Relationship on their Job Satisfaction and Voluntary Service Intentions (웨딩산업종사자의 교환관계가 직무만족과 자발적 서비스 의도에 미치는 영향에 관한 연구)

  • Byun, Sang-Woo;Lee, Hyang-Sook
    • Management & Information Systems Review
    • /
    • v.32 no.5
    • /
    • pp.69-88
    • /
    • 2013
  • This study aimed to analyze the effects that the exchange relationship among employees engaged in the wedding industry in Busan, Ulsan and Gyeongnam area exerted on job satisfaction and voluntary service intentions. For this purpose, a theoretical model was presented based on previous studies and the relationship among variables was analyzed based on the analysis results through a survey. There have recently been great difficulties in the whole wedding industry due to the global economic depression and the low birthrate. Moreover, it is hard to optimize the future business environment. In particular, the low birthrate has weakened the demand base of the wedding industry. As a result, it is expected that the competition among companies will be more fierce in the wedding industry. Employees' voluntary service intention become much more important to overcome difficulties in this industry. Employees' voluntary service intentions can be possible when their job satisfaction is achieved. Many studies report the result that this job satisfaction can naturally be achieved when the high quality exchange relationship among a leader, team members (co-workers) and customers is formed. It is viewed that employees' voluntary service intentions should be induced through job satisfaction to improve the profitability through the efficient operation and management of the system. A leader of the organization should make an effort to form the high-quality exchange relationship with members, support so that team members(coworkers) and other employees can get along together and the teamwork can be improved and induce them to improve a high level of service quality with friendly customer services. In spite of the significance of the study discussed above, there are the following limitations in this study. There is a limit to a certain extent in generalizing study conclusions because the study was limited to the Busan, Ulsan and Gyeongnam area. If practical surveys which full- and part-time employees are included in the composition of samples are conducted for wedding suppliers in the country in the future, the quality of study will be able to improve.

  • PDF