• 제목/요약/키워드: System Air Conditioner

검색결과 408건 처리시간 0.03초

저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구 (The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors)

  • 황윤제;조은준;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

Energyplus를 이용한 고효율 멀티에어컨디셔너의 에너지절감 효과 분석 (A Study on analyze of energy saving rate by retrofitting multi air-conditioner from conventional type to high efficient type using Energyplus)

  • 서정식;김욱중;우정태;최연성;전종욱
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.165.2-165.2
    • /
    • 2010
  • The objective of this study is to analyze the energy saving rate by retrofitting multi air conditioner from conventional type to high efficient type using Energyplus 4.0 which was developed for simulating a building energy by D.O.E. Generally, Multi air conditioner system was installed for both the cooling and the heating in a building. However, it was difficult to estimate the energy saving rate in the case of retrofitting multi air conditioner from conventional type to high efficient type. In the present study, annual energy consumptions of them were evaluated for same building and climate condition.

  • PDF

실외온도 변화에 따른 R410A 적용 에어콘 시스템의 성능 (Performance of a room air conditioner using R410A according to the variation of outdoor temperature)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.537-541
    • /
    • 1999
  • The system performance of a room air conditioner using R410A was experimentally evaluated and compared with that of R22 system. The results indicated that the cooling EER(energy efficiency ratio) of R410A was 1% higher than that of R22 at the outdoor temperature of $35^{\circ}C$. As outdoor temperature increases above $35^{\circ}C$ ambient, EER of the R410A system decreased more substantially compared with R22 system. R410A showed higher compressor discharge temperature than that of R22 system at the outdoor temperature of higher than $50^{\circ}C$.

  • PDF

Context Aware Services using Multi-Environmental Sensors and Its application for Ubiquitous Home Networks

  • Quang, Bui Dang;Torregoza, John Paul M.;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제10권6호
    • /
    • pp.786-798
    • /
    • 2007
  • As we go about our daily lives, people often collect surrounding information and adapt to the situation. Computer development trends show that one wants computers to work like human beings, i.e. computers can sense its context and adapt corresponding to context changes. To implement this expectation, a context aware service layer is needed. In this layer, sensors capture its environment and send this information to the service center. Considering received information as its context, the service center seeks the suitable operation according to the context. Tills paper presents a context aware service which is applied in controlling air-conditioner. The air-conditioner includes sensors which are installed at some special positions in a room. Each of these sensors gathers comfort-influenced information like temperature, humidity and sends them to air-conditioner. The air-conditioner adapts its operation to the environment according to the sensed information. To control the air-conditioner effectively, we use a genetic algorithm which is suitable in adaptation issues. The simulation shows that the room condition can be maintained at a comfortable level by using context-aware services in the operation of the air-conditioning system.

  • PDF

전력선 통신을 이용한 에어컨 피크 전력 제어 시스템 개발 (Development of Air Conditioner Peak Electric Power Control System using Power Line Communication)

  • 한재용;이순흠
    • 전자공학회논문지SC
    • /
    • 제46권5호
    • /
    • pp.44-51
    • /
    • 2009
  • 본 논문에서는 전력선 통신을 이용한 에어컨 피크 전력 제어 시스템을 개발하였다. 기존의 유선 RS-485통신 방식의 경우 별도의 통신 선로 설치가 필요하여 기존 건물에 설치하기 어려운 문제점과 무선 통신 방식의 경우 차폐된 공간에서는 설치가 용이하지 못한 문제점을 전력선 통신 방식을 채택하여 개선하였다. 기존에는 단상에만 적용된 것을 3상 4선식에도 적용할 수 있도록 개선하여 국내 모든 전기 환경에서 설치가 가능하도록 하였다. 전력선 통신을 이용한 타 시스템의 경우 전력선 모뎀을 별도로 부착하도록 되어 있으나 본 논문에서는 일체형으로 설계 구현하여 안정성 및 경제성을 높였다. 따라서 본 시스템의 가장 큰 장점인 설치의 용이성, 안전성과 경제성으로 인하여, 보다 확대 적용이 가능하여 에너지 절약이 절실히 필요한 현 시점에서 에어컨 피크 전력 관리 시스템의 활성화에 크게 기여 할 수 있을 것이다. 본 논문에서 구현된 시스템의 검증은 원격 에어컨 제어기 및 전력선 게이트웨이에 대한 설계 검증 시험과 전체 시스템의 필드 시험을 통해 성능 및 신뢰성의 우수함을 검증하였다.

HFC152a 대체냉매를 이용한 자동차 냉방장치의 성능 최적화에 관한 연구 (Study of Performance Optimization as an Alternative Refrigerant HFC152a in a Mobile Air Conditioning System)

  • 이대웅
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.321-327
    • /
    • 2015
  • This study presents an HFC152a refrigerant air conditioner as an alternative to HFC134a, which is currently used in mobile air conditioning systems. Cool-down performance tests of an HFC152a air conditioning system were conducted and compared to a baseline HFC134a air conditioner. The experimental set-up consisted of a belt-driven compressor, a sub-cooled type condenser, an evaporator, and a block-type thermal expansion valve (TXV). A drop-in test was carried out on the mobile air conditioning system under various vehicle running speeds in a climate-controlled wind tunnel (CWT). Additionally, to optimize the HFC152a air conditioning system, the effects of the TXVs on the performance were studied. The results show that compared to the HFC134a air conditioning system, the refrigerant charge quantity was reduced by approximately 20%, the discharge pressure was reduced by about 350~430 kPa, and the air discharge temperature at vehicle running conditions was $0.5{\sim}1.5^{\circ}C$ lower. In addition, good compressor durability was expected due to the lower compression ratio.

시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선 (Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control)

  • 최호식;권우현;윤병근
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

냉방시 시스템에어컨과 환기유닛 적응 강의실에서 실내 $CO_2$ 농도와 국소평균공기연령 연구 (Study on the Relationship between Indoor $CO_2$ Concentration and Local Mean Air-age in the Lecture Room with System Air-conditioner and Ventilation Unit for Cooling Loads)

  • 장재수;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.736-745
    • /
    • 2005
  • This study is undertaken to evaluate the relationship between the indoor $CO_2$ concentration and the local mean air-age in the lecture room with the occupants. We conducted the experiments to examine the indoor $CO_2$ concentration and the local mean air-age with respect to the supply airflow of the ventilation system and the discharge angle and air-flow of the system air conditioner. Through the experiments, we found out that indoor $CO_2$ concentrations calculated by the prediction equation of Seidel are about 350 ppm lower than those measured by the experiments. The indoor $CO_2$ concentration is not related with the air-flow and the discharge angle of the system air-conditioner, but with the ventilation airflow. From the numerical calculation, the indoor $CO_2$ concentration is not related with the ventilation effectiveness, but strongly with the local mean air-age. In case of our model, the indoor $CO_2$ concentration is likely to fall within the acceptable air quality when the local mean air-age is averagely predicted under 400 seconds.

멀티형 에어컨의 기간에너지소비효율 평가규격에 관한 연구 (An Overview on Standards for Seasonal Performance Evaluation of Multi-type Air Conditioners)

  • 박윤철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.91-100
    • /
    • 2004
  • Energy efficiency evaluation method for a multi-type air conditioning system still has not been developed. In this study, analysis on capacity range and evaluating method of standards for air conditioners was conducted with world-wide Standards. It is not a proper approach to use the standards for residential air conditioner to multi type air conditioners. Some difficulties and problems are commented in this study with overview of the standards. Through the analytic research, an evaluating method for multi type air conditioner was suggested with Integrated Part Load Value (IPLV). The suggested concept for evaluating energy efficiency during part load condition considers building load pattern and operating hours of the system at different locations. Load was weighted in IPLV to consider not only the concept of occurrence of outdoor temperature such as bin method but also operation hours of the system. An experiment about the IPLV was conducted with variable air volume ducted type air conditioning system and multi-type system through modified code tester to give a glance at quantitative value of the IPLV.