• Title/Summary/Keyword: Syringe

Search Result 360, Processing Time 0.027 seconds

진공노즐식 파종기의 최적 작동조건 (Optimum Operating Conditions of a Vacuum Nozzle Seeder)

  • 민영봉;김성태;정태상
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.463-470
    • /
    • 2000
  • For maximum seeding efficiency of a nozzle type seeder, the performance of the nozzle should be considered sufficiently. This study was carried out to investigate the optimum operating conditions of a seeder attached the vacuum nozzle which was modified syringe needle acting on the plug seedling tray and the seed plate. Such operating factors as the hole diameter of the nozzle (d), the distance from the nozzle tip to the bottom plate of seed hopper(D) the absorbing air pressure of the nozzle tip(P) the bounding height of seed from the vibrated bottom plate of seed hopper and the seeding speed were selected based on the weight of a grain of seed(W). The treated materials were pepper seed as the flat type, cucumber seed as the oval type and radish seed as the spherical type. The optimum operating conditions of the experimental seeder were revealed as follows: 1. The height of the seed bounding from the bottom plate of seed hopper and the distance from nozzle tip to bounded seed were 5 mm and 0.5 mm at all seeds. The hole diameter of the nozzle and the absorbing pressure for pepper seed, cucumber seed and radish seed was 0.45 mm, 0.65 mm. 0.65mm and 39.2 kPa, 88.3 kPa, 58.8 kPa, respectively. 2. The absorbing pressure P was represented as P=η.4W/$\pi$d$^2$ where η was 100. The seeding speed using a 128 cell tray was 2.4 cm/s which was same transfer as 2.5 trays per minute. 3. The maximum seeding rate in case of the pepper seed was 97% the cucumber seed was 95% and the radish seed was 100% under the optimum operating conditions of the seeder.

  • PDF

Intracordal Cartilage Injection For Vocal Fold Augmentation : Results for 2 Years

  • Lee, Byung-Joo;Wang, Soo-Geun;Goh, Eui-Kyung;Chon, Kyon-Myong;Roh, Hwan-Jung;Lee, Il-Woo
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 2003년도 제19회 학술대회
    • /
    • pp.181-181
    • /
    • 2003
  • Objectives : Vocal fold augmentation using injectable material is an easy and simple operation. This study is to evaluate the histology of minced and injected autologous auricular cartilage and fat graft in the augmentation of unilateral vocal fold paralysis using a canine model for two years. Study Design : A prospective study with the contralateral side of the larynx used as the control Methods : Twelve dogs were operated. At first, a piece of auricular cartilage was harvested from ear and minced into tiny chips with a scalpel and scissors. And also, a piece of fat tissue was harvested from inguinal area and minced into tiny chips with a scalpel and scissors. The minced cartilage and fat-paste (0.2ml) was injected using a pressure syringe into the paralyzed thyroarytenoid muscle under direct laryngoscopy. Two animals were sacrificed at 3 days, three at 3 weeks. two at 3 months. one at 6 months, one at 12 months, three at 24 months. Each dog underwent laryngectomy and serial coronal sections of paraffin blocks from the posterior part of the vocal fold were made. Result : There was no significant complication perioperatively and during follow-up. There was acute inflammatory findings in the graft at 3 days and 3 weeks. Only a very small proportion of the injected cartilage was absorbed due to the degenerative change and the overall volume was preserved even when the cells died out. The injected cartilage remained in the larynx until 24 months. Conclusion : The autologous cartilage implant using auricular cartilage was the ideal vocal cord augmentative material for the treatment of glottic incompetence.

  • PDF

Introcordal Injection of Autologous Fibroelastic Cartilage - Introcordal Injection of Autologous Fibroelastic Cartilage in the Paralyzed Canine Vocal Fold

  • Lee, Byung-Joo;Wang, Soo-Geun;Lee, Jin-Choon
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 2003년도 제19회 학술대회
    • /
    • pp.180-180
    • /
    • 2003
  • Objectives : Vocal fold augmentation by injectable material under direct visual control is an easy and simple operation. However, when autologous fat or bovine collagen is used, resorption creates a problem. And autologous fascia is debating about absorption now days. This study is to evaluate the histology of minced and injected autologous auricular cartilage and fat graft in the augmentation of unilateral vocal fold paralysis using a canine model. Methods : Nine dogs were operated. At first, a piece of auricular cartilage was harvested from ear and minced into tiny chips with a scalpel. And also, a piece of fat tissue was harvested from inguinal area and minced into tiny chips with a scalpel. Cutting off a section of the recurrent nerve paralyzed the right vocal fold. The minced cartilage and fat-paste (0.2ml) was injected using a pressure syringe into the paralyzed thyroarytenoid muscle under direct laryngoscopy. Two animals were sacrificed at 3 days, three at 3 weeks, two at 3 months, one at 6 months, one at 12 months. Each dog underwent laryngectomy and serial coronal sections of paraffin blocks from the posterior part of the vocal fold were made. Results : There was no significant complication perioperatively and during follow-up. There was acute inflammatory findings in the graft at 3 days and 3 weeks. The injected cartilage remained in the larynx until 12 months. Conclusion : The autologous auricular cartilage graft is well tolerated and may be very effective material for volumetric augmentation on paralyzed vocal cord.

  • PDF

생분해성 고분자 용착을 위한 기반 공정 개발과 이를 이용한 수술 후 유착 방지막의 제작 (Fundamental Process Development for Bio-degradable Polymer Deposition and Fabrication of Post Surgical Anti-adhesion Barrier Using the Process)

  • 박석희;김효찬;김택경;정현정;박태관;양동열
    • 한국정밀공학회지
    • /
    • 제24권4호
    • /
    • pp.138-146
    • /
    • 2007
  • Some biodegradable polymers and other materials such as hydrogels have shown the promising potential for surgical applications. Post surgical adhesion caused by the natural consequence of surgical wound healing results in repeated surgery and harmful effects. Recently, scientists have developed absorbable anti-adhesion barriers that can protect a tissue from adhesion in case they are in use; however, they are dissolved when no longer needed. Although these approaches have been attempted to fulfill the criteria for adhesion prevention, none can perfectly prevent adhesions in all situations. Overall, we developed a new method to fabricate an anti-adhesion membrane using biodegradable polymer and hydrogel. It employed a highly accurate three-dimensional positioning system with pressure-controlled syringe to deposit biopolymer solution. The pressure-activated microsyringe was equipped with fine-bore nozzles of various inner-diameters. This process allowed that inner and outer shapes could be controlled arbitrarily when it was applied to a surgical region with arbitrary shapes. In order to fulfill the properties of the ideal barriers f3r preventing postoperative adhesion, we adopted the pre-mentioned method combined with surface modification with the hydrogel coating by which anti-adhesion property was improved.

Visual Analysis for Detection and Quantification of Pseudomonas cichorii Disease Severity in Tomato Plants

  • Rajendran, Dhinesh Kumar;Park, Eunsoo;Nagendran, Rajalingam;Hung, Nguyen Bao;Cho, Byoung-Kwan;Kim, Kyung-Hwan;Lee, Yong Hoon
    • The Plant Pathology Journal
    • /
    • 제32권4호
    • /
    • pp.300-310
    • /
    • 2016
  • Pathogen infection in plants induces complex responses ranging from gene expression to metabolic processes in infected plants. In spite of many studies on biotic stress-related changes in host plants, little is known about the metabolic and phenotypic responses of the host plants to Pseudomonas cichorii infection based on image-based analysis. To investigate alterations in tomato plants according to disease severity, we inoculated plants with different cell densities of P. cichorii using dipping and syringe infiltration methods. High-dose inocula (${\geq}10^6cfu/ml$) induced evident necrotic lesions within one day that corresponded to bacterial growth in the infected tissues. Among the chlorophyll fluorescence parameters analyzed, changes in quantum yield of PSII (${\Phi}PSII$) and non-photochemical quenching (NPQ) preceded the appearance of visible symptoms, but maximum quantum efficiency of PSII ($F_v/F_m$) was altered well after symptom development. Visible/near infrared and chlorophyll fluorescence hyperspectral images detected changes before symptom appearance at low-density inoculation. The results of this study indicate that the P. cichorii infection severity can be detected by chlorophyll fluorescence assay and hyperspectral images prior to the onset of visible symptoms, indicating the feasibility of early detection of diseases. However, to detect disease development by hyperspectral imaging, more detailed protocols and analyses are necessary. Taken together, change in chlorophyll fluorescence is a good parameter for early detection of P. cichorii infection in tomato plants. In addition, image-based visualization of infection severity before visual damage appearance will contribute to effective management of plant diseases.

Characterizations of Modified Silica Nanoparticles(II) ; Preparation and Application of Silica Nanoparticles as a Environmentally Filler

  • Min, Seong-Kee;Bae, Deok-Kwun;Park, Sang-Bo;Yoo, Seong-Il;Lee, Won-Ki;Park, Chan-Young;Seul, Soo-Duk
    • 한국재료학회지
    • /
    • 제22권8호
    • /
    • pp.433-438
    • /
    • 2012
  • A chemical process involves polymerization within microspheres, whereas a physical process involves the dispersion of polymer in a nonsolvent. Nano-sized monodisperse microspheres are usually prepared by chemical processes such as water-based emulsions, seed suspension polymerization, nonaqueous dispersion polymerization, and precipitation polymerizations. Polymerization was performed in a four-necked, separate-type flask equipped with a stirrer, a condenser, a nitrogen inlet, and a rubber stopper for adding the initiator with a syringe. Nitrogen was bubbled through the mixture of reagents for 1 hr. before elevating the temperature. Functional silane (3-mercaptopropyl)trimethoxysilane (MPTMS) was used for the modification of silica nanoparticles and the self-assembled monolayers obtained were characterized by X-ray photoelectron spectroscopy (XPS), laser scattering system (LSS), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), elemental analysis (EA), and thermogravimetric analysis (TGA). In addition, polymer microspheres were polymerized by radical polymerization of ${\gamma}$-mercaptopropyl modified silica nanoparticles (MPSN) and acrylamide monomer via precipitation polymerization; then, their characteristics were investigated. From the elemental analysis results, it can be concluded that the conversion rate of acrylamide monomer was 93% and that polyacrylamide grafted to MPSN nanospheres via the radical precipitation polymerization with AAm in ethanol solvent. The microspheres were successfully polymerized by the 'graft from' method.

악취황 성분의 채취와 샘플백 내부의 시료 유실율 비교: 검량선의 기울기를 이용한 평가 (Reduced sulfur gas loss in the bag sampling procedure - Comparison by calibration slope values)

  • 김기현;최여진;안지원
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.338-343
    • /
    • 2005
  • 본 연구에서는 실온조건에서 황성분의 채취에 사용하는 두 가지 백 방식의 시료회수율을 비교 분석하였다. 이를 위해, 가스-타잇 주사기 내부에서 원표준시료를 희석하여 검량선을 작성하였다. 그리고 이에 대비하여 테들러 백이나 플리에스터 백으로 희석한 표준시료를 이용하여 검량선을 확보하였다. 가스타잇 주사기로 확보한 검량선과 백으로 확보한 검량선의 기울기를 비교하는 방식으로 백방식의 시료 손실 또는 회수율을 비교분석한 결과, 테들러 백의 경우 평균 87%의 회수율, 폴리에스터 백의 경우 평균 77% 수준의 회수율이 관측되었다. 결과적으로 백방식으로 시료를 채취할 경우, 시료의 손실이 확인되었다. 따라서 백방식의 현장시료 채취를 할 경우, 시료의 손실에 대한 가능성을 염두에 두고 이와 관련된 여러 가지 인자들을 동시에 검정하는 것이 중요하다고 결론지을 수 있다.

37% 인산 부식제에 의해 발생한 안면피부의 화학 화상 (IATROGENIC CHEMICAL BURN ON FACIAL SKIN BY 37% PHOSPHORIC ACID ETCHANT)

  • 박종현;신혜진;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제34권1호
    • /
    • pp.38-41
    • /
    • 2009
  • 복합레진 수복을 위해 상아질에 total-etch adhesive system을 적용할 경우, 37% 인산 산부식제가 널리 사용되고 있다. 37% 인산은 매우 강력한 부식제로 구강점막이나 안면피부와 접촉되었을 때 심각한 해로운 효과가 발생될 수 있다. 이 증례 보고에서는 복합레진 수복과정에서 사용된 인산 산부식제에 의해 안면피부에 발생된 의원성 화학적 화상을 보고하고자 한다. 산부식제에 의한 화학적 화상은 산부식제를 부주의하고 부적절하게 사용함으로 발생될 수 있으며, 이러한 의원성 손상을 방지하기 위해서는 산부식과 수세과정 후 산부식제가 완전히 제거되었는지를 확인하여야하며, 복합레진 수복 시 러버댐이나 적절한 격리 기구를 사용하는 것이 필요할 것이다. 화상이 발생하였다면, 적절한 응급처치 후 피부과로 의뢰하는 것이 필요할 것이다.

Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

  • Park, Sunju;Sun, Seung-Ho
    • 대한약침학회지
    • /
    • 제18권3호
    • /
    • pp.42-48
    • /
    • 2015
  • Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC) in male and female Sprague-Dawley (SD) rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP) regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS) after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge). The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection) and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal) groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

초음파를 이용한 Bladder형태에 따른 잔뇨량 측정의 정확도 연구 (A Study on the Accuracy of Measurement of Residual Urine Amount depending on the Bladder form using Ultrasonic)

  • 김연민;박태훈;김진혁;김수지;조다훈;허진영;한동균
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to increase the accuracy of the diagnosis of benign prostatic hyperplasia by presenting a method that can accurately measure the residual urine amount of the bladder by using an ultrasound image. Agar powder, Propanol and distilled water were used as materials for making a phantom. In order to measure the volume, a $10m{\ell}$ cylinder, syringe and beaker were used. The image was obtained by scanning phantoms produced into six shapes. Each constant value was obtained by using the expression designed to measure the residual urine amount of the bladder and was compared and analyzed. The measuring method of Bladder volume was presented and a constant value for each shape was obtained and five observers measured it five times. According to the results of clinical application, the errors of Ellipse-beanbag, Shield-shield were 11.0%, 18.2%, respectively. Constant values depending on the shape of each phantom were presented in order to accurately measure the volume of the bladder in measuring the amount of residual urine for the diagnosis of benign prostatic hyperplasia. The accuracy of the volume using this was verified statistically(p > 0.05). Therefore, it is considered to be useful in diagnosing benign prostatic hyperplasia by using the ultrasound imaging measuring method presented.

  • PDF