• 제목/요약/키워드: Synoptic weather analysis

검색결과 98건 처리시간 0.031초

용평 알파인 경기장에서 겨울철 바람의 일변화 및 난류 특성분석 (An Analysis of the Wintertime Diurnal Wind Variation and Turbulent Characteristics over Yongpyong Alpine Slope)

  • 전혜림;김병곤;은승희;이영희;최병철
    • 대기
    • /
    • 제26권3호
    • /
    • pp.401-412
    • /
    • 2016
  • A 3D sonic anemometer has been installed at Yongpyong alpine slope since Oct. 23th 2014 to observe the slope winds and to analyze turbulent characteristics with the change in surface cover (grass and snow) and the synoptic wind strength. Eddy covariance method has been applied to calculate the turbulent quantity after coordinate transformation of a planar-fit rotation. We have carefully selected 3 good episodes in the winter season (23 October 2014 to 28 February 2015) for each category (9 days in total), such as grass and snow covers in case of weak synoptic wind condition, and grass cover of strong synoptic wind. The diurnal variations of the slope winds were well developed like the upslope wind in the daytime and downslope wind in the nighttime for both surface covers (grass and snow) in the weak synoptic forcing, when accordingly both heat and momentum fluxes significantly increased in the daytime and decreased in the nighttime. Meanwhile, diurnal variation of heat flux was not present on the snow cover probably in associated with significant fraction of sunlight reflection due to high albedo especially during the daytime in comparison to those on the grass cover. In the strong synoptic regime, the most dominant feature at Yongpyong, only the southeasterly downslope winds were steadily generated irrespective of day and night with significant increases in momentum flux and turbulent kinetic energy as well, which could suggest that local circulations are suppressed by the synoptic scale forcing. In spite of only one season analysis applied to the limited domain, this kind of an observation-based study will provide the basis for understanding of the local wind circulation in the complex mountain domain such as Gangwon in Korea.

영동 지역의 극한 대설 사례와 관련된 종관 환경 (Synoptic Environment Associated with Extreme Heavy Snowfall Events in the Yeongdong Region)

  • 권태영;조영준;서동희;최만규;한상옥
    • 대기
    • /
    • 제24권3호
    • /
    • pp.343-364
    • /
    • 2014
  • This study presents local and synoptic conditions associated with extreme heavy snowfall events in the Yeongdong region, as well as the temporal and spatial variability of these conditions. During the last 12 years (2001~2012), 3 extreme snowfall events occurred in the Yeongdong region, which recorded daily snowfall greater than 50 cm, respectively. In these events, one of the noticeable features is the occurrence of heavy hourly snowfall greater than 10 cm. It was reported from satellite analysis that these heavy snowfall may be closely related to mesoscale convective clouds. In this paper the 3 extreme events are examined on their synoptic environments associated with the developments of mesoscale convective system using numerical model output. These 3 events all occurred in strongly forced synoptic environments where 500 and 300 hPa troughs and 500 hPa thermal troughs were evident. From the analysis of diagnostic variables, it was found in all 3 events that absolute vorticity and cold air advection were dominant in the Yeongdong region and its surrounding sea at upper levels, especially at around 500 hPa (absolute vorticity: $20{\sim}60{\times}10^{-5}s^{-1}$, cold air advection: $-10{\sim}-20^{\circ}C$ $12hr^{-1}$). Moreover, the spatial distributions of cold advection showed mostly the shape of a narrow band along the eastern coast of Korea. These features of absolute vorticity and cold advection at 500 hPa were sustained for about 10 hours before the occurrence of maximum hourly snowfall.

지역규모 장거리 대기오염 이동물질의 환경영향평가를 위한 종관기상 조건의 분류 (Classification of Synoptic Meteorological Patterns for the Environmental Assessment of Regional-scale Long Range Transboundary Air Pollutants)

  • 김철희;손혜영;김지아;안태건
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.89-98
    • /
    • 2007
  • In order to conduct the environmental assessment of long range transboundary air pollutants over East Asia, the moving pathways of air pollutants are of great importance, which are depending upon the meteorological weather patterns. Therefore regional scale modeling study requires the identified geopotential height distribution patterns to deal with behaviors of long range transport air pollutants for the effective long term atmospheric environmental assessment. In this study the synoptic meteorological classification using cluster analysis technique over Northeast Asia, and its previous applications of the regional scale air pollutant modeling studies were reviewed and summarized in detail. Other synoptic meteorological characteristics over Korean peninsula are also discussed.

미국 남부지방 도시호우의 종관적 분석 (Synoptic Analysis of Heavy Rainstorms over Urban Areas in the Southern United States)

  • Youngeun Choi
    • 대한지리학회지
    • /
    • 제33권3호
    • /
    • pp.395-409
    • /
    • 1998
  • 미국남부지방의 5개 도시를 연구지역으로 도시의 영향에 의한 강수특성변화를 파악하고 종관기상유형에 따른 특성을 규명하기 위하여 2 인치(50.08 mm) 이상의 일강수량을 가지는 강수일을 선택하여 3가지 강수유형(기단성 강수, 전선성 강수, 열대저기업성 강수)으로 구분하여 분석하였다. Houston, Dallas, 그리고 San Antonio에서는 기단성 강수가 발생할 때, 도시직역과 풍하측에 호우로 인한 강수량과 강수빈도의 증가가 나타나고 있으나 New Orleans와 Memphis에서는 종관적 분석을 통해서 볼 때 현저한 증가현상을 보이지 않는다. 경향면 분석겨로가는 전선성 강수와 열대저기업성강수 발생시 기단성 강수로 인한 호우보다 강한 경향성을 가지는 것을 보여주고, 호우로 인한 통강수량은 강수일수빈도보다 강한 경향성을 가진다. 잔차도 분석결과는 기단성 호우 발생시 도시지역과 풍하지역에 양의 잔차가 나타나는 것을 보여준다. 미국 남부의 5개도시에서 강수특성변화에 미치는 도시화의 영향에 대한 연구는 도시기후는 종관적으로 유사한 조건하일지라도 도시의 규모, 공간구조, 수체의 유무, 산업구조 등 다양한 특성에 따라 상이하게 반응함을 알 수 있었다.

  • PDF

황해에서 발생한 동계 고기압형 기상해일의 기상학적 원인분석: 2005년 12월 21일 사례를 중심으로 (Meteorological Analysis of a Meteo-tsunami caused by a High Pressure System during Winter on the Yellow Sea, South Korea: A Case Study of 21 December 2005)

  • 이호재;김유근;김현수;우승범;김명석
    • 한국환경과학회지
    • /
    • 제25권6호
    • /
    • pp.853-864
    • /
    • 2016
  • Meteo-tsunamis are tsunamis that are typically caused by strong atmospheric instability (e.g., pressure jumps) in low pressure systems, but some meteo-tsunamis in winter can be caused by local atmospheric instability in high pressure systems (e.g., the Siberian High). In this study, we investigated a meteo-tsunami event related to a high pressure system that occurred during winter on the Yellow Sea in 2005. Sea level data from tidal stations were analyed with a high-pass filter, and we also performed synoptic weather analyses by using various synoptic weather data (e.g., surface weather charts) collected during the winter season(DJF) of 2005. A numerical weather model (WRF) was used to analyze the atmospheric instability on the day of the selected event (21 Dec. 2005). On the basis of the results, we suggest that the meteo-tsunami triggered by the high pressure system occurred because of dynamic atmospheric instability induced by the expansion and contraction of the Siberian High.

장마전선상에서 하층제트 유입으로 인한 집중호우에 관한 연구 (A Study on the Heavy Rainfall Cases Associated with Low Level Jet Inflow along the Changma Front)

  • 최지영;신기창;류찬수
    • 통합자연과학논문집
    • /
    • 제4권1호
    • /
    • pp.44-57
    • /
    • 2011
  • In general, heavy rainfall in Korea is mostly associated with inflow of 850hPa low-level jet. It transports abundant heat and moisture flux to the Changma front. In this study, synoptic characteristics of heavy rainfall in Korea from a case study is examined by classifying heavy rainfall cases with synoptic patterns, in particular distribution of upper- and low-level jets, western North Pacific high, and moisture flux. The surface and upper-level weather charts including auxiliary analysis chart and radar and satellite images obtained from the Korea Meteorological Administration, and 500hPa geopotential heights from NCEP/NCAR are used and then KLAPS is applied to understand the local atmospheric structure associated with heavy rainfall. Results show that maximum frequency in 60 heavy rainfall cases with more than 150mm/day appears in the Changma type of 43 cases (a proportion in relation to a whole is 52%) including the combined Changma types with typhoon and cyclone. As indicated in previous studies, most heavy rainfall cases are related to inflow of low-level jet. In addition, synoptic characteristics based on the analyses of weather charts, radar and satellite images, and KLAPS in heavy rainfall case of 12 July, 2009 reveal that the atmospheric vertical structure in particular equivalent potential temperature favorable for effective inflow of warm and moist southwesterly into the Changma front is linked to large potential instability and the strong convergence accompanied with low-level jet around Suwon contributes to atmospheric upsliding along the Changma front, producing heavy rainfall.

연강수량 및 클러스터 기법에 의한 강수의 지역화 분석(수공) (Regional Analysis of Precipitation using Mean Annual Precipitation and Cluster Methods)

  • 이순혁;맹승진;류경식;지호근
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.397-404
    • /
    • 2000
  • A total of 65 rain gauges with Automatic Weather Station(AWS) were used to regional analysis of precipitation. Nine cluster regions were identified using geographical locations, maximum, mean, standard deviation of 1 day maximum rainfalls, mean annual precipitation and rainfall of rainy season in Korea. The mean annual precipitation, geographical locations, and the synoptic generating mechanisms were used to identify th five climatological homogeneous regions in Korea. Number of final regions by mean annual precipitation and cluster methods divided into five regions in Korea.

  • PDF

짙은 황사와 연무가 공존한 대기의 에어러솔 특성 - 2009년 3월 15~17일 - (The Aerosol Characteristics in Coexistence of Asian Dust and Haze during 15~17 March, 2009 in Seoul)

  • 이해영;김승범;김수민;송승주;전영신
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.168-180
    • /
    • 2011
  • The variation of the physicochemical properties of atmospheric aerosols in coexistence of the heavy Asian Dust and Haze observed from $15^{th}$ to $17^{th}$ March 2009 in Seoul was scrutinized through the mass and ion concentration observations and synoptic weather analysis. Although the ratio of PM1.0/PM10 was constant at 0.3 (which is typical during Asian Dust period in Korea) during the measurement period, both PM10 and PM1.0 mass concentrations were 3~6 times and 2~4 times higher than that of clear days, respectively. Water-soluble ion components accounted for 30~50% of PM10 and 50~70% of PM1.0 mass concentration. One of the secondary pollutants, $NO_3^-$ was found to be associated with $Ca^{2+}$ and $Na^+$ in coarse mode indicating that the aerosol derived from natural source was affected by anthropogenic pollutants. While the acidity of the aerosols increased in fine mode when the stagnation of weather patterns was the strongest (March $16^{th}$), the alkalinity increased in coarse mode when new air masses arrived with a southwestern wind after ending a period of stagnation (March $17^{th}$). In the selected case, SOR (Sulfur Oxidation Ratio, $nSO_4^{2-}/[nSO_4^{2-}+nSO_2]$) and NOR (Nitrogen Oxidation Ratio, $nNO_3^-/[nNO_3^-+nNO_2]$) values of ion components were higher than the general values during Asian Dust period. These results imply that dust aerosols could be mixed with pollutants transported from China even in heavy Asian Dust cases in Korea.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • 제27권5호
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.