• 제목/요약/키워드: Synchronous reference frame (SRF)

검색결과 33건 처리시간 0.027초

A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters

  • Monfared, Mohammad;Golestan, Saeed;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.692-700
    • /
    • 2013
  • This paper discusses the design of a novel synchronous reference frame (SRF) method that can extract the reference compensating current for single-phase shunt active power filters (APFs). Unlike previous SRF studies, the proposed method has an innovative feature that does not require a fictitious current signal. Other key features of the proposed strategy include frequency-independent operation, accurate reference current extraction, and relatively fast transient response. The effectiveness of the proposed method is investigated by conducting a detailed mathematical analysis. Results of the analysis confirm the superior performance of the suggested approach. Theoretical evaluations are confirmed by the experimental results.

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

교류전기철도 급전시스템의 전기품질 향상을 위한 단상 하이브리드 능동필터 (A Single-Phase Hybrid Active Filter for AC Electrified Railway Systems)

  • 박한얼;송중호
    • 한국철도학회논문집
    • /
    • 제13권2호
    • /
    • pp.152-158
    • /
    • 2010
  • 교류 전기철도 급전시스템은 고조파 왜곡 및 무효전력으로 인한 역률저하 등의 전기품질 문제를 동반한다. 교류 전기철도 급전시스템의 고조파 전류 및 무효전력을 보상하기 위해 SRF(synchronous-reference-frame) 제어를 이용한 하이브리드 능동필터를 제안한다. 제안하는 하이브리드 능동필터 제어 알고리즘은 3상에서만 응용되었던 MSRF(multiple-synchronous-reference-frames)를 통해 저차 고조파를 추출하여 상대적으로 크기가 작은 고차 고조파를 능동필터에서 보상하고 크기가 큰 저차 고조파를 수동필터에서 보상하며, 능동필터 또는 수동필터만을 사용했을 때 생길 수 있는 문제점들 보완한다. 또한, 폐루프 무효전력 보상알고리즘을 통해 무효전력을 보상한다. 시뮬레이션을 통해 제안하는 하이브리드 능동필터의 SRF 제어 방법의 제어 성능과 타당성을 확인한다.

단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구 (A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters)

  • 황선환;황영기;권순걸
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters

  • Han, Yang;Shen, Pan;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.297-309
    • /
    • 2016
  • Grid-connected inverters (GCIs) with an LCL output filter have the ability of attenuating high-frequency (HF) switching ripples. However, by using only grid-current control, the system is prone to resonances if it is not properly damped, and the current distortion is amplified significantly under highly distorted grid conditions. This paper proposes a synchronous reference frame equivalent proportional-integral (SRF-EPI) controller in the αβ stationary frame using the parallel virtual resistance-based active damping (PVR-AD) strategy for grid-interfaced distributed generation (DG) systems to suppress LCL resonance. Although both a proportional-resonant (PR) controller in the αβ stationary frame and a PI controller in the dq synchronous frame achieve zero steady-state error, the amplitude- and phase-frequency characteristics differ greatly from each other except for the reference tracking at the fundamental frequency. Therefore, an accurate SRF-EPI controller in the αβ stationary frame is established to achieve precise tracking accuracy. Moreover, the robustness, the harmonic rejection capability, and the influence of the control delay are investigated by the Nyquist stability criterion when the PVR-based AD method is adopted. Furthermore, grid voltage feed-forward and multiple PR controllers are integrated into the current loop to mitigate the current distortion introduced by the grid background distortion. In addition, the parameters design guidelines are presented to show the effectiveness of the proposed strategy. Finally, simulation and experimental results are provided to validate the feasibility of the proposed control approach.

Improved DC Offset Error Compensation Algorithm in Phase Locked Loop System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1707-1713
    • /
    • 2016
  • This paper proposes a dc error compensation algorithm using dq-synchronous coordinate transform digital phase-locked-loop in single-phase grid-connected converters. The dc errors are caused by analog to digital conversion and grid voltage during measurement. If the dc offset error is included in the phase-locked-loop system, it can cause distortion in the grid angle estimation with phase-locked-loop. Accordingly, recent study has dealt with the integral technique using the synchronous reference frame phase-locked-loop method. However, dynamic response is slow because it requires to monitor one period of grid voltage. In this paper, the dc offset error compensation algorithm of the improved response characteristic is proposed by using the synchronous reference frame phase-locked-loop. The simulation and the experimental results are presented to demonstrate the effectiveness of the proposed dc offset error compensation algorithm.

A Simplified Synchronous Reference Frame for Indirect Current Controlled Three-level Inverter-based Shunt Active Power Filters

  • Hoon, Yap;Radzi, Mohd Amran Mohd;Hassan, Mohd Khair;Mailah, Nashiren Farzilah;Wahab, Noor Izzri Abdul
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1964-1980
    • /
    • 2016
  • This paper presents a new simplified harmonics extraction algorithm based on the synchronous reference frame (SRF) for an indirect current controlled (ICC) three-level neutral point diode clamped (NPC) inverter-based shunt active power filter (SAPF). The shunt APF is widely accepted as one of the most effective current harmonics mitigation tools due to its superior adaptability in dynamic state conditions. In its controller, the SRF algorithm which is derived based on the direct-quadrature (DQ) theory has played a significant role as a harmonics extraction algorithm due to its simple implementation features. However, it suffers from significant delays due to its dependency on a numerical filter and unnecessary computation workloads. Moreover, the algorithm is mostly implemented for the direct current controlled (DCC) based SAPF which operates based on a non-sinusoidal reference current. This degrades the mitigation performances since the DCC based operation does not possess exact information on the actual source current which suffers from switching ripples problems. Therefore, three major improvements are introduced which include the development of a mathematical based fundamental component identifier to replace the numerical filter, the removal of redundant features, and the generation of a sinusoidal reference current. The proposed algorithm is developed and evaluated in MATLAB / Simulink. A laboratory prototype utilizing a TMS320F28335 digital signal processor (DSP) is also implemented to validate effectiveness of the proposed algorithm. Both simulation and experimental results are presented. They show significant improvements in terms of total harmonic distortion (THD) and dynamic response when compared to a conventional SRF algorithm.

직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법 (A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator)

  • 장훈;이우철;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

단상 계통연계 인버터의 SRF 전력제어 방법 (A SRF Power Flow Control Method for Grid-Connected Single-Phase Inverter Systems)

  • 박한얼;김은석;송중호
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.129-135
    • /
    • 2010
  • 화석에너지의 고갈과 환경오염 문제를 해결하기 위한 대안인 신재생 에너지를 이용하는 분산발전 시스템은 핵심 구성 요소인 PWM 인버터의 전력제어가 요구된다. 본 논문에서는 단상 계통연계 인버터 시스템의 전력제어를 위해 계통 임피던스를 고려한 SRF(synchronous-reference-frame) 전력제어 방법을 제안한다. 제안한 SRF 전력제어 방법은 복잡한 계통 임피던스의 추정 없이 계통 임피던스의 공칭값(nominal value)에 기반해 단상 인버터에 전압 기준값(reference)을 제공하여 독립운전 모드와 계통연계 모드에서 모두 운전이 가능함을 나타내었다. 또한, 유효전력과 무효전력의 독립적인 제어가 가능한 장점을 가진다. 계통을 포함하는 시뮬레이션을 통해 제안한 SRF 전력제어 방법의 타당성을 검증한다. 시뮬레이션 결과는 제안한 SRF 전력제어 방법을 통해 단상 계통연계 인버터 시스템의 전력 흐름을 적절히 제어할 수 있음을 보여주고 있다.

A Canonical Small-Signal Linearized Model and a Performance Evaluation of the SRF-PLL in Three Phase Grid Inverter System

  • Mao, Peng;Zhang, Mao;Zhang, Weiping
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.1057-1068
    • /
    • 2014
  • Phase-locked loops (PLL) based on the synchronous reference frame (SRF-PLL) have recently become the most widely-used for grid synchronization in three phase grid-connected inverters. However, it is difficult to study their performance since they are nonlinear systems. To estimate the performances of a SRF-PLL, a canonical small-signal linearized model has been developed in this paper. Based on the proposed model, several significant specifications of a SRF-PLL, such as the capture time, capture rang, bandwidth, the product of capture time and bandwidth, and steady-state error have been investigated. Finally, a noise model of a SRF-PLL has been put forward to analyze the noise rejection ability by computing the SNR (signal-to-noise ratio) of a SRF-PLL. Several simulation and experimental results have been provided to verify and validate the obtained conclusions. Although the proposed model and analysis method are based on a SRF-PLL, they are also suitable for analyzing other types of PLLs.