• 제목/요약/키워드: Synchronous Generation Source

검색결과 33건 처리시간 0.02초

PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구 (A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization)

  • 안종보;김원곤;황기현;박준호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

Modelling and Performance Analysis of UPQC with Digital Kalman Control Algorithm under Unbalanced Distorted Source Voltage conditions

  • Kumar, Venkateshv;Ramachandran, Rajeswari
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1830-1843
    • /
    • 2018
  • In this paper, the generation of a reference current and voltage signal based on a Kalman filter is offered for a 3-phase 4wire UPQC (Unified Power Quality Conditioner). The performance of the UPQC is improved with source voltages that are distorted due to harmonic components. Despite harmonic and frequency variations, the Kalman filter is capable enough to determine the amplitude and the phase angle of load currents and source voltages. The calculation of the first state is sufficient to identify the fundamental components of the current, voltage and angle. Therefore, the Kalman state estimator is fast and simple. A Kalman based control strategy is proposed and implemented for a UPQC in a distribution system. The performance of the proposed control strategy is assessed for all possible source conditions with varying nonlinear and linear loads. The functioning of the proposed control algorithm with a UPQC is scrutinized and validated through simulations employing MATLAB/Simulink software. Using a FPGA SPATRAN 3A DSP board, the proposed algorithm is developed and implemented. A small-scale laboratory prototype is built to verify the simulation results. The stated control scheme for the UPQC reduces the following issues, voltage sags, voltage swells, harmonic distortions (voltage and current), unbalanced supply voltage and unbalanced power factor under dynamic and steady-state operating conditions.

해양시설물용 하이브리드 발전시스템 설계 (A design of Hybrid power generation system for Ocean facilities)

  • 정성영;오진석
    • 한국항해항만학회지
    • /
    • 제33권6호
    • /
    • pp.381-385
    • /
    • 2009
  • 일반적으로 해양 시설물은 대부분 태양광 기반의 발전 시스템으로 구성된다. 태양광 발전 시스템은 날씨의 광량에 따라 변화한다. 태양광 발전 시스템은 흐린 날과 비오는 날에 전력 생산량이 감소한다. 태양광 발전량이 부족해지면 해양 시설물에 전력 부족이 발생한다. 이러한 문제를 해결하기 위하여 본 논문은 태양광과 파력 시스템을 복합한 하이브리드 발전 제어 시스템을 제안한다. 파력 발전 시스템은 웰스 터빈과 영구자석 발전기로 구성되어 있다. 제안하는 시스템을 특별한 지역에 설치하고 태양광 발전 전력과 파력 발전 전력을 측정하였다. 실험결과 태양광 전력은 파력에 비하여 안정적인 전원이다. 그러나 파력은 태양이 없는 동안에도 전력을 공급할 수 있다. 제안하는 하이브리드 시스템의 전력 특성이 태양광 시스템에 비하여 높은 안정성을 갖는 것을 알 수 있다.

PSCAD/EMTDC를 이용한 동기기형 풍력 발전 시스템의 출력제어 (Power Control of Synchronous Machine Type Wind Power System Using PSCAD/EMTDC)

  • 한상근;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.201-203
    • /
    • 2002
  • In recent years there has been a growing interest in renewable energy systems due to the environmental problem and the economic benefits of fuel savings. Such systems are usually connected to the existing power grid for "fuel displacement" purpose as well as of earning some "capacity credit". Wind power generation system(WPGS) is one of the most useful energy resource using natural environment. So far, it was very difficult to simulate the dispersed generation system including WPGS using EMTP or EMTDC because the source of the dispersed generation system has a particular wind power characteristic equation. In this paper, a novel simulation method of WPGS has proposed and a new wind turbine component for EMTDC is also developed. The wind power characteristic equation of wind turbine is used in order to realize the WPGS in EMTDC simulation. And the real field data of weather conditions is interfaced to EMTDC using Fortran program interface method. Consequently the simulation of WPGS using field data is realized in this paper and shows acceptable results.

  • PDF

LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성 (Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation)

  • 황락훈;나용주
    • 한국항행학회논문지
    • /
    • 제22권5호
    • /
    • pp.420-428
    • /
    • 2018
  • 본 논문은 태양광 발전시스템을 승압쵸퍼와 단상 펄스폭변조 전압형인버터를 사용하여 전원차단 경우나 전압변동 및 부하변동에 의한 출력전류 변화에도 일정한 출력전압을 유지하는 무정전 전원 공급장치(UPS)를 구성하였다. 본 시스템은 전압형인버터를 교류전원과 동기 시켜서 운전하고 정상상태에서는 전원으로부터 운전하고 정상상태에서는 전원으로부터 직류 측에 연결된 축전지를 태양전지를 이용한 광기전력효과와 함께 일정전압을 충전하며, 전원의 차단, 전원의 전압변동 및 부하전류의 변화에도 일정한 전압을 유지하도록 하였다. 에너지 저장장치 (ESS; energy storage system)를 상시 운영하여 공항의 기상 변화에 따른 파장별 LED 항공 유도신호 등을 효율적으로 운용하는 시스템을 구성 하였고, 전력절감효과를 얻을 수 있는 에너지절약 전원복합형 전력변환장치로 구성되어 있다. 출력은 PWM방식에 의하여 양호한 파형이 되도록 하고 전원차단과 부하의 상태의 변화 및 전원 전압 변동에도 일정한 전압으로 출력됨을 실험을 통하여 확인 할 수 있었다.

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

STATCOM의 특성해석을 위한 동적모델 고찰 (Dynamic Model Study for the Analysis of the STATCOM Characteristics)

  • 김선호;원동준;한학근;이송근;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1039-1041
    • /
    • 1999
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. [2] STATCOM is a voltage source inverter(VSI) based static VAr compensator with only small capacitors on the do side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. [1] This paper compares the PAM STATCOM with PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods was presented.

  • PDF

Grid-friendly Characteristics Analysis and Implementation of a Single-phase Voltage-controlled Inverter

  • Zhang, Shuaitao;Zhao, Jinbin;Chen, Yang;He, Chaojie
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1278-1287
    • /
    • 2017
  • Inverters are widely used in distributed power generation and other applications. However, their lack of inertia and variable impedance may cause system instability and power transfer inaccuracy. This paper proposes a control scheme for a single phase voltage-controlled inverter with some grid-friendly characteristics. The proposed control algorithm enables the inverter to function as a voltage source with an inner output impedance in both the islanded and grid-connected modes. Virtual inertia and rotor equations are embedded in the PLL part. Thus, the frequency stability can remain. The inner output impedance can be adjusted freely, which helps to accurately decouple and transmit the output active and reactive power. The proposed inverter operates like a traditional synchronous generator. Simulations and experiments are designed and carried out to verify the proposed control strategy.

STATCOM의 출력전압 구현방식에 따른 동특성 해석 (The Dynamic Characteristics Analysis of the STATCOM According to the Realization of the STATCOM Output Voltage)

  • 김선호;원동준;한학근;이송근;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.323-331
    • /
    • 2000
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. The STATCOM is a voltage source inverter(VSI) based on the static VAr compensator with only small capacitors on the dc side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. This paper compared the PAM STATCOM with the PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods is presented.

  • PDF

2.5G SDH 전자파 감소용 저역통과필터 설계 (Design of Low Pass Filter to reduce EMI from 2.SG SDH system)

  • 이성원;김영범
    • 한국시뮬레이션학회논문지
    • /
    • 제10권4호
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF