• Title/Summary/Keyword: Synchronized operation

Search Result 119, Processing Time 0.024 seconds

New Eight-phase ZCD spreading sequences design for Interference-cancelled WPAN based on AS-CDMA

  • Cha, Jae-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.44-47
    • /
    • 2008
  • New Eight-phase Preferred Pairs (EPPs) that have Zero-Correlation Duration (ZCD) of (0.5N+1) chips are constructed for the periods of $N=4{\times}2n$ (n=1,2,3...). By using the chip-shift operation of the EPP, new eight-phase ZCD sequences are constructed in this paper. We certified its ZCD property by various correlation simulations. This new eight-phase spreading sequence can be used for Interference cancelled wireless personal area network(WPAN) based on approximately synchronized code-division-multiple-access(AS-CDMA) system.

Realtime Wireless Sensor Line Protocol for Forest Fire Monitoring System (실시간 센서 네트워크 프로토콜을 이용한 산불 모니터링 시스템의 구현)

  • Kim, Jae-Ho;Lee, Sang-Shin;Ahn, Il-Yeup;Kim, Tae-Hyun;Won, Kwang-Ho;Kim, Seong-Dong
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1031-1034
    • /
    • 2005
  • This paper introduces a novel sensor network protocol, R-WSLP(Realtime Wireless Sensor Line Protocol), which has extremely low latency characteristic in large-scale WSN. R-WSLP is proposed to implement realtime forest fire monitoring system. We propose Distributed TDMA method for the multiple channel access and Time Synchronized Forwarding Mechanism instead of routing technique to achieve low latency network. Also, R-WSLP provides extremely low power operation which we accomplished by reducing idle listening. In our experimentation, we get successful results at the forest fire monitoring system with our protocol.

  • PDF

Spectral Analysis of LFO Using Synchrophasor in KEPCO Systems (Synchrophasor를 이용한 한전계통의 저주파 진동 스펙트럴 해석)

  • Shim, Kwan-Shik;Choi, Jun-Ho;Kim, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.63-73
    • /
    • 2013
  • The parameters of electromechanical modes offer considerable insight into the dynamic stability properties of a power system. This paper presents a results of a LFO(low-frequency oscillation) based on the time-synchronized signals measured by synchrophasor in the rolling blackout. Spectral analysis was performed, and critical parameters were estimated using the data acquired from synchrophasors installed in the KEPCO system. As significant modes, a 0.68 Hz oscillation mode that occurred prior to the forced load shedding in the rolling blackout was estimated. Such an oscillation mode can cause an uncontrollable blackout. Therefore, the system should be operated so that significant oscillation modes are not activated. This results can serve as a reference in the future for reliable system operation in the event of a similar blackout.

Design of a Frequency Locked Loop Circuit

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • In this paper, I propose the full CMOS FLL(frequency locked loop) circuit. The proposed FLL circuit has a simple structure which contains a FVC(frequency-to-voltage converter), an operational amplifier and a VCO(voltage controlled oscillator). The operation of FLL circuit is based on frequency comparison by the two FVC circuit blocks. The locking time of FLL is short compared to PLL(phase locked loop) circuit because the output signal of FLL is synchronized only in frequency. The circuit is designed by 0.35${\mu}m$ process and simulation carried out with HSPICE. Simulation results are shown to illustrate the performance of the proposed FLL circuit.

A Design and Construction of Speed Encoder for High Performance Driving of SRM (SRM 고정도 구동을 위한 위치 및 속도엔코더의 설계 및 제작)

  • Kang, Yu-Jung;Oh, Seok-Kyu;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1191-1193
    • /
    • 2001
  • In switched reluctance motor(SRM) drive, it is necessary to synchronize the stator phase excitation with the rotor position. Therefore, the rotor position information is essential. Usually, optical encoders or resolvers are used to provide the rotor position information. These sensors are expensive and are not suitable for high speed operation. This paper proposes a new encoder for high performance excitation control of SRM. The proposed encoder has complex structures of incremental and absolute encoder. An each phase inductance profile can be synchronized with 4-bit absolute position signal and incremental pulses are used for speed detection. Low cost and simple structure are possible.

  • PDF

Real-time 3D Graphic Simulation of the Spent Fuel Rod Extracting Machine for Remote Monitoring (사용후핵연료봉 인출장치의 원격감시를 위한 실시간 3차원 그래픽 시뮬레이션)

  • 송태길;이종열;김성현;윤지섭
    • Korean Journal of Computational Design and Engineering
    • /
    • v.5 no.4
    • /
    • pp.327-335
    • /
    • 2000
  • The spent fuel rod extracting machine is automatically operated in high radioactive environment, so high reliability of operation is required. In this paper, to enhance the reliability of this machine by providing a close monitoring capability. a real time graphic simulation method is suggested. This method utilizes conventional IGRIP (Interactive Graphics Robot Instruction Program) 3D graphic simulation tool to visualize and simulate the 3D graphic model of this machine. Also, the dedicated protocol is defined for transmission of the operational data of the machine. The real time graphic simulation is realized by developing the socket module between a graphic workstation and a machine control computer through the TCP/IP network and by dividing the 3D graphic simulation GSL(Graphic Simulation Language) program as a small sized sub routine. The suggested method is implemented while automatically operating the rod extracting machine. The result of implementation shows that the real time 3D graphic simulation is well synchronized with the actual machine according to the operational data.

  • PDF

Power System Fault Monitoring System using Wavelelet Transform and GPS for Accurate Time Synchronization (웨이블릿 변환과 GPS 정밀시각동기를 이용한 전력계통 고장점 모니터링 시스템에 관한 연구)

  • Kim, Gi-Taek;Kim, Hyuck-Soo;Choi, Jung-Yong
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.105-110
    • /
    • 2001
  • A continuous and reliable electrical energy supply is the objective of any power system operation. A transmission line is the part of the power system where faults are most likely to happen. This paler describes the use of wavelet transform for analyzing power system fault transients in order to determine the fault location. Synchronized sampling was made possible by precise time receivers based on GPS time reference, and the sampled data were analyzed using wavelet transform. This paper describes a fault location monitoring system and fault locating algorithm with GPS, DSP processor, and data acquisition board, and presents some experimental results and error analysis.

  • PDF

Study on a Distrbuted control system for industrial robot peripherals (산업용 로봇트 주변장치의 분산제어에 관한 연구)

  • 김대훈;변증남
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 1980
  • A distributed control system is designed and imp, fomented to control various pert pherals of a playback-type industrial robot :or synchronized work motion. The distn buted control system conslists of a 16- bit Mini-computer and several 8bit Micro-computers. In the paper, the struttuie of the control system, the software requirements for system operation as well as the hierarchical computer network for interfacing module computers and the Mini - computer are briefly described. and practical difficulties including including interfacing problem ate discussed.

  • PDF

Improving Breakdown Voltage Characteristics of GDAs using Trigger Voltage

  • Lee, Sei-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.646-652
    • /
    • 2010
  • This paper investigates a method to improve the breakdown voltage characteristics of a gas discharge arrester (GDA) for a surge suppressor. The middle electrode is inserted between two terminal electrodes. Voltage application to the electrode synchronized and amplified by the impulse voltage decreases spark overvoltage from 45% to 57.6%. The decrease is caused by higher voltage slope, as opposed to applied impulse voltage (by 5.5 to 6.2 times). In addition, the GDA model using ATP-Draw was used to analyze the operation characteristics of GDAs. The test and simulation results agree to within 2% when the trigger source was used.

A Study on the Power Monitoring System using GPS for Accurate Time Synchronization (GPS 정밀시각동기를 이용한 전력계통 모니터링 시스템에 관한 연구)

  • 김혁수;전성준;김기택
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.285-285
    • /
    • 2000
  • A continuous and reliable electrical energy supply is the objective of any power system operation. A transmission line is the part of the power system where faults are most likely to happen. This paper describes the use of wavelet transform for analyzing power system fault transients in order to determine the fault location. Synchronized sampling was made possible by precise time receivers based on GPS time reference, and the sampled data were analyzed using wavelet transform. This paper describes a fault location monitoring system and fault locating algorithm with GPS, DSP processor, and data acquisition board, and presents some experimental results and error analysis.

  • PDF