• Title/Summary/Keyword: Synchronization Methods

Search Result 277, Processing Time 0.024 seconds

Synchronization of Flowering for Hybrid Com Seed Production by Clipping Young Plants Clear Polyethylene Mulching and Planting Date (옥수수 교잡종채종에 있어 유식물절단 비닐피복 및 파종기에 의한 자식계통 개화기조절)

  • Kang, Y.K.;Park, K.Y.;Ham, Y.S.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.28 no.4
    • /
    • pp.481-487
    • /
    • 1983
  • The need to synchronize flowering in two lines of different maturities is frequently encountered in hybrid com (Zea mays L.) seed production. To establish the methods for synchrony of flowering in parent lines of different maturities be effects of clipping at 4 and 6-leaf stages of growth and two levels, clear polyethylene mulching and five different planting dates on flowering date growth and seed yield of two dent com inbred lines of different maturities were evaluated Clipping just above the shoot-apex delayed pollen sheeding 6 to 9days and silking 5 to 13 days but reduced stand and seed yield 30 to 70% and 67 to 81%. respectively. Clipping 5cm above the shoot apex delayed flowering 1 to 4 days without stand reduction but reduced yield 3 to 29%. Laterclipping was slightly more effective for delaying flowering than earlier clipping but reduced stand more severely when clipped just above the shoot apex. Under clear polyethylene film mulching, flowering of two lines was 13 to 15 days earlier and seed yield of B68 (late line) was significantly increased. As planting was delayed from April 18 to June 13, the number of days from planting to flowering of two lines decreased due to increase in air temperature. However, growing degree days (GDD) from planting to flowering of each lines was similar regardless planting dates indicating that GDD can be satisfactoryly used for choosing the planting dates of parent lines of different maturities. Seed yields of two lines were decreased with delaying planting dates.

  • PDF

Analyzing environmental factors influencing the gestation length and birth weight of Hanwoo cattle

  • Shil Jin;Sung-Sik Kang;Jeong Il Won;Hyoun Ju Kim;Sun Sik Jang;Sung Woo Kim
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.39 no.2
    • /
    • pp.121-130
    • /
    • 2024
  • Background: This study focused on reproductive traits in Hanwoo cattle, specifically the environmental factors affecting gestation length and birth weight. Methods: The records of 1,540 cows calved at the Hanwoo Research Institute from 2015 to 2023 were examined. This study analyzed two populations, line-breeding Hanwoo (LBH) and general Hanwoo (GH), with all cows undergoing estrus synchronization and artificial insemination. The R software was used to compare the differences between the two populations and analyze the environmental factors affecting each trait. Results: The results showed that the average gestation length for LBH was 283.28 ± 5.93 days, which was significantly shorter than that of the GH, which had an average of 285.63 ± 6.21 days (p < 0.001). The average birth weight of LBH calves was 25.10 ± 3.69 kg, significantly lighter than GH calves, which weighed 27.26 ± 4.11 kg on average (p < 0.001). Analysis of environmental factors revealed significant differences in the gestation length of LBH based on dam parity, year, and season of calving. However, no significant differences were observed based on calf sex. For LBH, birth weight showed significant differences based on dam parity, year of calving, and sex of the calf, but not the season of calving. In GH, gestation length varied with dam parity and calving season, but not with calving year or calf sex. The GH birth weight showed differences based on dam parity, year of calving, and calf sex, but not the season of calving. Conclusions: Reproductive traits in the Hanwoo cattle industry are economically vital but are heavily influenced by environmental factors due to their low heritability. An accurate evaluation of the genetic potential of these traits requires an analysis of the environmental factors affecting them. The results of this study serve as foundational data for predicting the potential for genetic improvement in the gestation length and birth weight of Hanwoo cattle.

A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data (스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식)

  • Kim, Kilho;Choi, Sangwoo;Chae, Moon-jung;Park, Heewoong;Lee, Jaehong;Park, Jonghun
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.163-177
    • /
    • 2019
  • As smartphones are getting widely used, human activity recognition (HAR) tasks for recognizing personal activities of smartphone users with multimodal data have been actively studied recently. The research area is expanding from the recognition of the simple body movement of an individual user to the recognition of low-level behavior and high-level behavior. However, HAR tasks for recognizing interaction behavior with other people, such as whether the user is accompanying or communicating with someone else, have gotten less attention so far. And previous research for recognizing interaction behavior has usually depended on audio, Bluetooth, and Wi-Fi sensors, which are vulnerable to privacy issues and require much time to collect enough data. Whereas physical sensors including accelerometer, magnetic field and gyroscope sensors are less vulnerable to privacy issues and can collect a large amount of data within a short time. In this paper, a method for detecting accompanying status based on deep learning model by only using multimodal physical sensor data, such as an accelerometer, magnetic field and gyroscope, was proposed. The accompanying status was defined as a redefinition of a part of the user interaction behavior, including whether the user is accompanying with an acquaintance at a close distance and the user is actively communicating with the acquaintance. A framework based on convolutional neural networks (CNN) and long short-term memory (LSTM) recurrent networks for classifying accompanying and conversation was proposed. First, a data preprocessing method which consists of time synchronization of multimodal data from different physical sensors, data normalization and sequence data generation was introduced. We applied the nearest interpolation to synchronize the time of collected data from different sensors. Normalization was performed for each x, y, z axis value of the sensor data, and the sequence data was generated according to the sliding window method. Then, the sequence data became the input for CNN, where feature maps representing local dependencies of the original sequence are extracted. The CNN consisted of 3 convolutional layers and did not have a pooling layer to maintain the temporal information of the sequence data. Next, LSTM recurrent networks received the feature maps, learned long-term dependencies from them and extracted features. The LSTM recurrent networks consisted of two layers, each with 128 cells. Finally, the extracted features were used for classification by softmax classifier. The loss function of the model was cross entropy function and the weights of the model were randomly initialized on a normal distribution with an average of 0 and a standard deviation of 0.1. The model was trained using adaptive moment estimation (ADAM) optimization algorithm and the mini batch size was set to 128. We applied dropout to input values of the LSTM recurrent networks to prevent overfitting. The initial learning rate was set to 0.001, and it decreased exponentially by 0.99 at the end of each epoch training. An Android smartphone application was developed and released to collect data. We collected smartphone data for a total of 18 subjects. Using the data, the model classified accompanying and conversation by 98.74% and 98.83% accuracy each. Both the F1 score and accuracy of the model were higher than the F1 score and accuracy of the majority vote classifier, support vector machine, and deep recurrent neural network. In the future research, we will focus on more rigorous multimodal sensor data synchronization methods that minimize the time stamp differences. In addition, we will further study transfer learning method that enables transfer of trained models tailored to the training data to the evaluation data that follows a different distribution. It is expected that a model capable of exhibiting robust recognition performance against changes in data that is not considered in the model learning stage will be obtained.

The Assessment of the Breath Hold and the Free Breath Methods about the Blood Flow Evaluation by Using Phase Contrast MRI (위상대조도 자기공명영상을 이용한 심장 혈류평가에 있어서 호흡정지 기법과 비 호흡정지 기법의 비교평가)

  • Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were $96.17{\pm}19.12ml/sec$, $17.04{\pm}4.12cm/sec$ respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of $72.31{\pm}13.27ml$ and $12.32{\pm}3.85$. On the other hand, the average 2NEX blood flow and mean flow velocity is $101.90{\pm}24.09$, $16.84{\pm}4.32$, 3NEX $103.06{\pm}25.49$, $16.88{\pm}4.19$ did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were $76.68{\pm}19.72ml/s$, and $22.23{\pm}4.8$, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

The Changes of Short-Term Memory and Autonomic Neurocardiac Function after 4-10Hz Sound and Light Stimulation - A Pilot Study - (4-10 Hz 빛과 소리자극 후 단기기억력 및 자율신경심장기능의 변화 - 예비연구 -)

  • Lee, Seung-Hwan;Kim, Jin-Hwan;Park, Joong-Kyu;Lee, Kyung-Uk;Yang, Dae-Hyun;Hong, Keun-Young;Chae, Jeong-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Objectives: Sound and light (SL) stimulation has been used as a method to induce some useful mental states in the fields of psychology and psychiatry. It is believed that sound and light entrainment device (SLED) has some specific effects through synchronization of EEG in patients who use it. Theta frequency is believed to stimulate deep relaxation and short term memory processing. This study was conducted to evaluate if 4-10 Hz SL stimulation can induce relaxation and improve short term memory function. Methods: Ten medical students with no medical or psychiatric problems participated in this study. Subjects were randomly divided into two groups. One group was applied with real SLED was applied to one group (R group) and pseudo SLED to the other group (P group). The two groups were exposed to SL stimulation with SLED 15 minutes a day for 5 days, and after two days rest the two groups were switched over. The Korean Wechsler Adult Intelligence Scale (K-WAIS), Academic Motivation Tests (AMT), Test Anxiety Scale (TAS), Korean Auditory Verbal Learning Test (K-AVLT), and digit span were used to evaluate short term memory. Spielberger's State-Trait anxiety inventory and heart rate variability (HRV) test were used to evaluate degree of relaxation. Results: Compared with S group, R group showed a significant improvement in K-AVLT and digit span after a single application of SL stimulation. But 5-day long application did not reveal any differences between the two groups. A significant change in HRV was observed in 5-day long application of SL stimulation after being switched over to other SLED. Conclusion: This pilot study suggests that 4-10 Hz SL stimulation has some positive influences on short term memory and relaxation.

  • PDF

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF