• 제목/요약/키워드: Switching overvoltage

검색결과 72건 처리시간 0.025초

Analysis of Magnitude and Rate-of-rise of VFTO in 550 kV GIS using EMTP-RV

  • Seo, Hun-Chul;Jang, Won-Hyeok;Kim, Chul-Hwan;Chung, Young-Hwan;Lee, Dong-Su;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.11-19
    • /
    • 2013
  • Very Fast Transients (VFT) originate mainly from disconnector switching operations in Gas Insulated Substations (GIS). In order to determine the rate-of-rise of Very Fast Transient Overvoltage (VFTO) in a 550 kV GIS, simulations are carried out using EMTP-RV. Each component of the GIS is modeled by distributed line model and lumped model based on equivalent circuits. The various switching conditions according to closing point-on-wave and trapped charge are simulated, and the results are analyzed. Also, the analysis of travelling wave using a lattice diagram is conducted to verify the simulation results.

여자전류 재단에 따른 단락 시험용 변압기의 절연영향 평가 (Estimating the Effect of Overvoltage Results from Excitation Current Chopping in Short-circuit Transformer)

  • 오승렬;박지훈;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.78-80
    • /
    • 2007
  • The residual flux in transformer's iron cores leads to a distortion of short-circuit current occasionally. And some considerable distortion may have effect on the validation of the test results. To avoid the substantial distortion, a suitable pretest is performed before the actual test. In case of applying this method there must be excessive overvoltage due to switching of an unloaded transformer and chopping of an excitation current. The purpose of this paper is estimate that the effect of the overvoltage results from this phenomenon on insulation performance of short-circuit transformer.

  • PDF

EMTP 선로모델이 과전압 해석결과에 미치는 영향에 관한 연구 (A Study on the Effects of Line Constants Models for the Overvoltage Analysis in EMTP)

  • 김경탁;곽주식;권동진;구교선;우정욱
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.33-41
    • /
    • 2010
  • There are several overvoltages by abnormal conditions in power system. We need to calculate these ovevoltages for the insulation design and the fault analysis. For these calculations, we used EMTP(Electro-magnetic Transients Program). During EMTP calculations, the accurate modelling of the equipments is very important for analysis results. In this paper, we considered the effects of the modelling condition's changes for transmission line within EMTP modelling cases of overvoltage analysis. Specially, we considered CB closing cases of 765[kV] system. So, we had changed the calculation frequencies of Line Constants, which is used for CB closing cases. In addition, we compared the calculation result and the measured result.

EMTP/ATPDraw를 이용한 가스절연송전선로(GIL)의 과전압 분석 (An Analysis on the Overvoltage in Gas Insulated Transmission Lines with EMTP/ATPDraw)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.999-1004
    • /
    • 2011
  • Nowadays, it is becoming difficult to secure a transmission line route when a new transmission line is constructed due to social environment and resident complaints. As existing urban areas are expanded and new cities are constructed, the necessity of high-capacity underground power transmission has been increasing because of load concentration in downtown areas. In North America, Europe and Japan, the research has been carried out for 2nd generation gas insulated transmission lines(GIL) which is more environmentally friendly and economical compared to previous GILs. The new GILs have been applied to real power systems from early 2000s. In South Korea, GIL is being considered as a possible solution for replacing 345kV high-capacity overhead transmission lines with underground transmission ones, so KEPCO is planning to develop and apply a new 362kV rated GIL underground transmission lines instead of overhead transmission lines. In this paper, the overvoltage generated at the combined transmission line adapting GIL was reviewed using EMTP.

대용량 IGBT 스위칭 시 과전압 제한을 위한 향상된 게이트 구동기법 (An Improved Gate Control Scheme for Overvoltage Clamping Under High Power IGBTs Switching)

  • 김완중;최창호;이요한;현동석
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.222-230
    • /
    • 1998
  • 본 논문에서는 스너버 회로를 사용하지 않고 턴-온시 역회복 전류의 영향과 턴-오프 시 구동되는 IGBT에 발생하는 과전압을 제한할 수 있는 새로운 IGBT 게이트 구동회로를 제안한다. 제안하는 턴-온 게이트 구동기법은 턴-온 지연 시간을 증가시키지 않고 게이트-에이터 전압이 문턱전압 이상이 되면 IGBT의 입력 커패시턴스를 증가시킴으로써 게이트-에이터 전압의 증가율을 감소시키는 특징을 갖는다. 제안하는 턴-오프 게이트 구동기법은 전류의 크기에 따라 과전압을 제한하여 단락사고와 같은 대전류가 흐르는 경우 더욱 효과적으로 과전압을 제한하는 특징을 가진다. 또한, 여러 가지 조건에서 실험을 수행하여 제안한 IGBT 게이트 구동회로의 타당성을 검증한다.

  • PDF

Monitoring for Mutual Effects of Switching Power Capacitors in Power Systems

  • Ghania, Samy M.;Elwer, Ayman S.;Morsi, Reda;Salama, M.M.A.
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.325-331
    • /
    • 2008
  • Power system perturbations are due to many reasons; one of the most common perturbation causes is switching off/on the power capacitors. This paper monitors and discusses the overvoltages which appear on local and remote capacitor connected buses in power systems. Using the Fast Fourier Transfer (FFT), the total harmonic content of voltages and currents waveforms is also estimated at all buses. The power factor during different cases of switching modes "off/on" is monitored. The monitoring technique tackles not only the longitudinal long distance mutual effects of switching power capacitors between different buses but also evaluates the overvoltage durations. A relative long term monitoring is implemented using the Matlab/Simulink environment to show severity assessments in different switching modes on the transformers' voltages and currents' waveforms.

과전압에 의한 변압기 철공진 분석 및 방지대책 (Analysis for the Ferroresonance on the Transformer by Overvoltage and Prevention Measures)

  • 윤동현;신동열;차한주
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1543-1550
    • /
    • 2015
  • Ferroresonance is a non-linear vibrational phenomenon that is generated by the electrical interaction of the inductance component with the capacitor component of a certain capacitance as the device of the inductance component such as a transformer is saturated due to the degradation, the waveform distortion of current and voltage, and the oscillation of overcurrent and overvoltage in a system. Recently, ferroresonance was generated from the waveform distortion of current and voltage, or the overvoltage or undervoltage phenomenon caused by the nature of an electrical power system and design technology of the transformer in the three phase transformer system. Hence, in general, ferroresonance analyzed by converting to the LC equivalent circuit. However, in general, the aforementioned analytical method only applies to the resonance phenomenon that is generated by the interaction of the capacitance of bussbar and grounding, and switching as the capacitor component with PT and the transformer as the inductance component in a system. Subsequently, the condition where ferroresonance was generated since overvoltage was supplied as line voltage to the phase voltage and thus the iron core is saturated due to the interconnection between grounded and ungrounded systems could not be analyzed when single phase PT was connected in a ${\Delta}$/Y connection system. In this study, voltage swell in the configuration of grounded circuit of a step-up transformer with the ${\Delta}-{\Delta}$ connection linked to PT for control power and the ferroresonance generated by overvoltage when the line voltage of the ${\Delta}-{\Delta}$ connection was connected to the phase voltage of the grounded Y-Y connection were analyzed using PSCAD / EMTDC through the failure case of the transformer caused by ferroresonance in the system with the ${\Delta}-{\Delta}$/Y-Y connection, and subsequently, the preventive measure of ferroresonance was proposed.

태양광 발전 연계 계통에서 개폐서지 해석 (Analysis of Switching Surge in Distribution System with Photovoltaic Generation System)

  • 서훈철;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.698-699
    • /
    • 2011
  • This paper analyzes the switching surge in distribution system with photovoltaic (PV) generation system. The change of overvoltage by PV generation system is analyzed using lattice diagram. To verify the analysis results, the distribution system with PV generation system is modeled using EMTP-RV and the various simulations are performed.

  • PDF

혼합배전계통에서 EMTP/APTDraw를 이용한 개폐서지 해석에 관한 연구 (A Study and Analysis on the Switching Surge Using a EMTP/ATPDraw in the Combined Distribution System)

  • 이장근;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.175-177
    • /
    • 2005
  • This paper analyzes transient behavior due to switching overvoltage in 22.9kV combined distribution systems. Computer models are consisted of distribution overhead line model, underground cable model and surge-arrester model in this paper. The computer models are made by EMTP/ATPDraw simulation and Line constants are calculated by ATP_LCC. This paper analyzes the various parameters affecting. These factors include closing angle and cable length.

  • PDF