• Title/Summary/Keyword: Switching method

Search Result 2,711, Processing Time 0.03 seconds

A Design of Wideband Frequency Synthesizer for Mobile-DTV Applications (Mobile-DTV 응용을 위한 광대역 주파수 합성기의 설계)

  • Moon, Je-Cheol;Moon, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.40-49
    • /
    • 2008
  • A Frequency synthesizer for mobile-DTV applications is implemented using $0.18{\mu}m$ CMOS process with 1.8V supply. PMOS transistors are chosen for VCO core to reduce phase noise. The measurement result of VCO frequency range is 800MHz-1.67GHz using switchable inductors, capacitors and varactors. We use varactor bias technique for the improvement of VCO gain linearity, and the number of varactor biasing are minimized as two. VCO gain deterioration is also improved by using the varactor switching technique. The VCO gain and interval of VCO gain are maintained as low and improved using the VCO frequency calibration block. The sigma-delta modulator for fractional divider is designed by the co-simualtion method for accuracy and efficiency improvement. The VCO, PFD, CP and LF are verified by Cadence Spectre, and the sigma-delta modulator is simulated using Matlab Simulink, ModelSim and HSPICE. The power consumption of the frequency synthesizer is 18mW, and the VCO has 52.1% tuning range according to the VCO maximum output frequency. The VCO phase noise is lower than -100dBc/Hz at 1MHz at 1MHz offset for 1GHz, 1.5GHz, and 2GHz output frequencies.

A Study on Efficiency Improvement of X-Band Power Amplifier Using Harmonic Control Circuit (고조파 제어 회로를 이용한 X-대역 전력 증폭기의 효율 개선에 관한 연구)

  • Kim, Hyoung-Jong;Choi, Jin-Joo;Kim, Dong-Yoon;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.987-994
    • /
    • 2010
  • In this paper, a simple and effective active load-pull method is proposed, and the method to improve the efficiency of X-band power amplifier using harmonic control circuit is presented. The proposed active load-pull system mainly consists of directional coupler, phase shifter, short circuit, and power amplifier, and allows a user to access reflection coefficients near the edge of the Smith chart($\Gamma$=1) easily. The device used in this paper is Mitsubishi's GaAs FET MGF1801, and the operating frequency of the power amplifier is 9 GHz, The amplifier had output power of 21.65 dBm and drain efficiency of 24.9 % at class-A, and had output power of 21.46 dBm and drain efficiency of 53.3 % at class-AB. Harmonic control circuit is designed only second and third harmonic components because of the bandwidth limitation of the microwave components. The drain efficiency is improved as much as 6.4 % compared with class-AB power amplifier.

The electrical properties of PLZT thin films on ITO coated glass with various post-annealing temperature (ITO 기판에 제작된 PLZT 박막의 후열처리 온도에 따른 전기적 특성평가)

  • Cha, Won-Hyo;Youn, Ji-Eon;Hwang, Dong-Hyun;Lee, Chul-Su;Lee, In-Seok;Sona, Young-Guk
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.28-33
    • /
    • 2008
  • Lanthanum modified lead zirconate titanate ($Pb_{1.1}La_{0.08}Zr_{0.65}Ti_{0.35}O_3$) thin films were fabricated on indium doped tin oxide (ITO)-coated glass substrate by R.F magnetron sputtering method. The thin films were deposited at $500^{\circ}C$ and post-annealed with various temperature ($550-750^{\circ}C$) by rapid thermal annealing technique. The structure and morphology of the films were characterized with X-ray diffraction (XRD) and atomic force microscopy (AFM) respectively. The hysteresis loops and fatigue properties of thin films were measured by precision material analyzer. As the annealing temperature was increased, the remnant polarization value was increased from $10.6{\mu}C/cm^2$ to $31.4{\mu}C/cm^2$, and coercive field was reduced from 79.9 kV/cm to 60.9 kV/cm. As a result of polarization endurance analysis, the remnant polarization of PLZT thin films annealed at $700^{\circ}C$ was decreased 15% after $10^9$ switching cycles using 1MHz square wave form at ${\pm}5V$.

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

A Study on PCFBD-MPC in 8kbps (8kbps에 있어서 PCFBD-MPC에 관한 연구)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.18 no.5
    • /
    • pp.17-22
    • /
    • 2017
  • In a MPC coding using excitation source of voiced and unvoiced, it would be a distortion of speech waveform. This is caused by normalization of synthesis speech waveform of voiced in the process of restoration the multi-pulses of representation section. This paper present PCFBD-MPC( Position Compensation Frequency Band Division-Multi Pulse Coding ) used V/UV/S( Voiced / Unvoiced / Silence ) switching, position compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. Also, I was implemented that the PCFBD-MPC( Position Compensation Frequency Band Division-Multi Pulse Coding ) system and evaluate the SNRseg of PCFBD-MPC in coding condition of 8kbps. As a result, SNRseg of PCFBD-MPC was 13.4dB for female voice and 13.8dB for male voice respectively. In the future, I will study the evaluation of the sound quality of 8kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or a smart phone.

The Inplementation of Fault-Tolerant Dual System Using the Hot-Standby Sparing Technique (핫 스탠바이 스페어링 기법을 이용한 고장 감내 이중화 시스템 설계)

  • Shin Jin wook;Park Dong sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10A
    • /
    • pp.1113-1122
    • /
    • 2004
  • This paper is basically to achieve the high-availability and high-reliability of the control system from the implementation of the fault-tolerant system using the hot-standby sparing technique. To meet the objective, we design and implement a board with fault tolerance I/O bus to detect the fault. Warm-standby sparing technique is the fault tolerance technique usually used for switching control system in present. This technique can be easily implemented, but can not detect the fault quickly and can malfunction because of the hardware fault. The hot-standby sparing fault tolerant technique implemented in this paper is consists of dual processor modules and a I/O processor using fault tolerant I/O bus. The proposed method can find the faults as soon as possible, so it can prevent from wrong operation. Also it is possible to normal re-service due to the short recovering time. To implement the fault-tolerant dual system with fault detection be, two daughter, called FTMA and FTIA, boards designed and implemented are applied to the system. And we also simulated the proposed method to verify the high-availability and high-reliability of the control system using Markov process.

Suggestion of a Hybrid Method for Estimating Photovoltaic Power Generation (전력 IT 시스템에서 복합방식의 태양광 발전량 예측 방법 제안)

  • Ju, Woo-Sun;Jang, Min-Seok;Lee, Yon-Sik;Bae, Seok-Chan;Kim, Weon-Goo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.782-785
    • /
    • 2011
  • Needs for MG(Microgrid) development are increasing all over the world as a solution to the problems including the depletion problem of energy resources, the growing demand for electric power and the climatic and environmental change. Especially Photovoltaic power is one of the most general renewable energy resources. However there is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to climate fluctuation (variation of insolation and duration of sunshine, etc). As a solution to the above problem, ESS(Energy Storage System) is considered generally, but it has some limitations. To solve this problem this paper suggests a hybrid estimation method of photovoltaic power generation according to two climatic factors, i.e. insolation and sunshine. This result seems to help design the appropriate capacity of ESS and estimate the proper switching time between DC and AC power in the premises power system and thus maintain the uniformity of power quality.

  • PDF

A Study on Arterial Road Network Improvement Based on Networking Analysis (Networking 기반의 간선도로의 망기능 분석방법론 연구)

  • Jung, Kabchae;Kang, Kyeong Pyo;Kim, Jung Wan
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.1
    • /
    • pp.47-56
    • /
    • 2013
  • The present study proposed a methodology to analyze the networking efficiency of arterial road networks. The methodology was motivated to design three-dimensional networks and to analyze the networking ability quantitatively, which is a novel approach compared to existing methods depending on the two-dimensional network definition and the qualitative analysis for improving arterial road networks. The method considered the interdependence between high-level freeways and low-level highways, the ITS-based information for traffic and road conditions, and the physical networking. These three factors were quantified by a networking index (NI), and the networking efficiency was measured by a networking rate (NR). The present study proved that the networking efficiency (NR) was influenced by travel information sharing (i.e., ITS) and physical factors. This supports the fact that the integrated improvements of physical and ITS factors are necessary for an arterial road. The proposed method was applied for an actual arterial road network. It was found that the nation-wide NR was higher than that for the metropolitan area, which might be due to the difficulty in switching between high- and low-level networks and the lack of ITS functions in the metropolitan area.

Study on the Method of Analyzing the Plasticizer of Petrochemical Products using MD-GC/MS (MD-GC/MS를 활용한 석유화학제품의 가소제(DOA, DOP) 분석방법 연구)

  • Doe, Jin-woo;Youn, Ju-min;Kang, Hyung-kyu;Hwang, In-ha;Ha, Jong-han;Na, Byung-ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1085-1093
    • /
    • 2017
  • Plasticizers are materials added to give softness and elasticity to plastics having rigid properties to give soft properties as products, and they are mainly added to high molecular materials to give flexibility to improve workability and to improve cold resistance, resistance to volatility and electrical properties. It is used for the purpose. Most plasticizers are inert liquids, similar in function to solvents but with high molecular weight and no volatility. In addition, when dissolved in petrochemical products, only the plasticizer is separated by the matrix effect with other compounds, and qualitative and quantitative analysis. In this study, qualitative and quantitative analysis of DOA and DOP, which are representative components of petrochemical products, were conducted using MD-GC/MS and developed an optimal plasticizer analysis method.

Review of Safety Measures through Analysis of Accidents on the Vehicle-mounted MEWP(mobile elevated work platforms) (차량 탑재형 고소작업대의 사고분석을 통한 안전대책 고찰)

  • Lee, Junho
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.1 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • In this paper, we analyze various cases of accidents caused by vehicle-mounted MEWPs(mobile elevated work platforms) which are most widely used for the high position level works, review the safety improvement measures for each of them, and propose basic data for the revision of related laws. The accidents by MEWPs were caused by the high level of works, which lead to fatal personnel accidents, so the measures for safety must be thoroughly carried out and the obligatory regulations by the related laws must be strictly observed. In this paper, we classify the cases of accidents at the workshop as 4 representative types and propose measures and remedies for them. According to the current regulations, it is possible to prepare for the accidents such as the wire rope breakage by switching to the all-chain drive method which does not have a daily use time limit instead of the wire rope drive method which is widely used at present. Also, it is suggested to add the daily use timetable to the nameplate attachment duty item according to the driving class.