Torque Ripple Reduction in Direct Torque Control of Five-Phase Induction Motor Using Fuzzy Controller with Optimized Voltage Vector Selection Strategy

  • Shin, Hye Ung;Kang, Seong Yun;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1177-1186
    • /
    • 2017
  • This paper presents a torque ripple reduction method of direct torque control (DTC) using fuzzy controller with optimal selection strategy of voltage vectors in a five-phase induction motor. The conventional DTC method has some drawbacks. First, switching frequency changes according to the hysteresis bands and motor's speed. Second, the torque ripple is rapidly increased in long control period. In order to solve these problems, some/most papers have proposed torque ripple reduction methods by using the optimal duty ratio of the non-zero voltage vector. However, these methods are complicated in accordance with the parameter. If this drawback is eliminated, the torque ripple can be reduced compared with conventional method. In addition, the DTC can be simply controlled without the use of the parameter. Therefore, the proposed algorithm is changing the voltage vector insertion time by using the designed fuzzy controller. Also, the optimized voltage vector selection method is used in accordance with the torque error. Simulation and experimental results show effectiveness of the proposed control algorithm.

A Study on Simple Single phase Air-conditioner of Power factor Correction Circuit (심플한 단상 에어컨의 역률개선회로에 관한 연구)

  • 문상필;서기영;이현우;김영문;김영철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • This paper describes the simple single phase air-conditioner of power factor correction (PFC) circuit. By adopting PFC in the rectifier, we can reduce harmonic into power line, improve the efficiency and lower the total system cost compared to conventional inviter only. Also, system performance is improved by stabilizing the output voltage of PFC. To improve the current waveform of diode rectifiers, we propose a new operating principle for the voltage diode rectifiers. A circuit design method is shown by experimentation and confirmed simulation. It explained that compared conventional pulse-width modulated (PWM) inverter with half pulse-width modulated (HPWM) inverter HPWM inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting.

  • PDF

Analysis of a Three Phase PWM AC/DC Converter With Input Current Waveform and Power Factor Correction (입력 전류 파형과 역률 개선 제어기법에 의한 3상 PWM 컨버터 해석)

  • 이수흠;배영호;최종수;백종현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • This paper describes to control system for AC to DC converter which has been widely used to power source in industrial factory and domestics. In this paper, three-phase PWM AC to DC Boost converter that operates with unity power factor and sinusodial input line currents is presented. The current control of this converter is based on the predicted current control strategy with fixed switching frequency and the line currents track to reference currents within one sampling time interval. By using this control strategy low ripples in the output current and the voltage as well as fast dynamic response are achieved with small dc link capacitance employed.ployed.

  • PDF

Control of the Buck Converter using the Function Control Law (함수제어 기법을 이용한 Buck 컨버터 제어)

  • 이성백;원영진;김태웅
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.81-89
    • /
    • 1997
  • In order to achieve the zero voltage regulation of the output voltage, the function control law will be used. In the previous function control law, only the proportional controller is used and the stability of the closed loop system was not analyzed. In this paper, for the realization of the control law, a new method to retrieve the low frequency component of the inductor voltage is proposed and analyzed. The large signal closed loop characteristics are alos analyzed to ensure the stable operation of the system disturbances. By using the function control law in the control system, the effect of the disturbance of the supply voltage is reduced in 93.3% for the direct dusty ration method. Also, in the effect of the disturbance of the load current, the output voltage has a logn recovery-time and is changed proportionally in the direct duty ratio method, but has stable in the function control law. Finally, the analysis shows that the disturbance of the output voltage being due to the supply voltage variation can be eliminated completely and the closed loop output voltage is insensitive to the disturbance of the load current. Therefore, it is proved that by using the function control law, the switching power supply with zero-voltage regulation output voltage can be realized.

  • PDF

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

The Development of a Speed Changeable Current Controller for Driving a 10kW BLDC Motor for Revolving and Elevating a Turret a Tank (전차의 포탑 선회, 고저 구동용 10kW BLDC 전동기 가변속 전류제어기 개발)

  • Park, Moo-Yurl;Koo, Bon-Min;Choi, Jung-Keying
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.947-950
    • /
    • 2005
  • For revolving and elevating a turret of a tank, we substitute an existing oil pressure system with an electric system using a motor and applied the vector control method to this system. A switching method of an inverter for providing desired sinusoidal current to each phase of a motor, we adopted min-max pulse width modulation method which takes less computation time, rather than space vector pulse width modulation method. We designed a digital filter and applied it to the control system. Developed current controller is verified it's performance through a current control test, speed control test, frequency response and tracking a profile of speed test.

  • PDF

The power regulation of a High-Frequency Induction Heating System with time variance load using a neural fuzzy controller (뉴로퍼지 제어기를 이용한 고주파 유도 가열기의 시변부하에 대한 정전력 제어)

  • 장종승;김승철;임영도
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.223-230
    • /
    • 1998
  • This paper describes a phase-shift pulse-width modulation and pulse-frequency modulation series resonant high-frequency inverter using IGBT(Insulated-Gated Bipolar Transistor) for the power control of high-frequency induction heating using neuro-fuzzy, which is practically applied for 20KHz~500KHz induction-heating and melting power supply in industrial fields. The adaptive frequency tracking based phase-shifting PWM(Pulse-Width Modulation) regulation scheme is presented in order to minimize switching losses. The trially-produced breadboards using IGBT are successfully demonstrated and discussed.

  • PDF

Constructing the Switching Function using Decision Diagram (결정다이아그램을 사용한 스위칭함수 구성)

  • Park, Chun-Myoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.687-688
    • /
    • 2011
  • This paper presents a design method for combinational digital logic systems using time domain based multiplexing(TDBM) and common multi-terminal extension decision diagrams(CMTEDD). The proposed method can reduce the 1)hardware, 2)logic levels and 3)pins. In the logic system design, we use two types of decision diagrams(DDs), that is the common binary decision diagrams(CBDDs) and CMTEDDs. Also, we propose an algorithms to derive common multiple-terminal binary decision diagrams(CMTBDD) from CBDDs, and CMTEDDs from CMTBDDs. The CMTEDDs over CBDDs is more compactness in terms of number of non-terminal nodes, where the nodes for output selection variables are not included in the non-terminal nodes. In the logic design, each non-terminal nodes of an CBDDs and an CMTEDDs is realized by a multiplexer(MUX). In addition, we compare the proposed TDBM realization with the conventional one.

  • PDF

Turn-on/off Angle for Maximum Torque of SRM by Using Self-tuning Control (SRM의 자기동조 방식에 의한 최대토크의 턴-온/오프각 제어)

  • Seo Jong-Yun;Cha Hyun-Rok;Seo Jung-Chul;Yang Hyong-Yeol;Kim Kwang-Heon;Lim Young-Cheol;Jang Do-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.243-246
    • /
    • 2001
  • The control of the SRM(Switched Reluctance Motor) is usually based on the non-linear inductance profiles with positions. So determination of optimal switching angle is very different. This paper proposed that the determination method of turn-on/off angle in the SRM drives is to maintain the high torque, which is realized by using self-tuning control method. During the sampling time, a number of pulses from the encoder are checked by using micro-controller. And compared with pre-checked a number of pulses. After calculating difference between two data, turn-on/off angle moves forward or backward direction by using self-tuning method. The optimal turn-on/off angle is determined by iterating such a process and the maximum torque is maintained. Experimental results are provided to demonstrate the validity of the self-tuning controller.

  • PDF

Performance Analysis of Optical Line Termination System in ATM based Passive Optical Network (ATM 기반 수동 광가입자 망에서의 광선로 종단 시스템의 성능 분석)

  • Park, Sang-Jo;Kang, Koo-Hong
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.1
    • /
    • pp.40-47
    • /
    • 2002
  • This paper analyzes the performance of an optical line termination system in ATM based Passive Optical Network(PON) using the operational analysis. We analyze it using system parameters such as utilization, throughput and routing frequency based on the buffer structure in each block of ATM-PON. Furthermore, we derive the mean response time and the visit ratio of each block, and then search the bottleneck block that hinders the system performance. We found that the 622Mbps 16x16 switching block is the bottleneck block for ATM-PON. In this bottleneck block, the loss probability increases rapidly when the cell arrival rate increases.