• Title/Summary/Keyword: Switching Impulse

Search Result 83, Processing Time 0.028 seconds

STABILIZATION OF SWITCHED SYSTEMS WITH UNCONTROLLABLE SUBSYSTEMS

  • Zhu, Yanli;Sun, Yuangong
    • Journal of applied mathematics & informatics
    • /
    • v.31 no.5_6
    • /
    • pp.895-906
    • /
    • 2013
  • In this paper, we study the stabilization problem of switched systems with both controllable and uncontrollable subsystems. By using an average dwell time approach, we first establish a sufficient condition such that the switched system is exponentially stabilizable under appropriate switching signals. We also extend this result to the switched system with nonlinear impulse effects and disturbances. Numerical examples are given to illustrate the theoretical results.

PD Characteristics of inverter-fed AC motor subjected to impulse voltage in electric train (전동차내 임펄스 전압인가에 따른 인버터구동형 유도전동기의 PD 특성)

  • Lee, Kang-Won;Kim, Ryong-Myung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.564-565
    • /
    • 2005
  • AC induction motor equipped in electric train is driven by VVVF inverter which produces switching pulse like impuse. Impulse voltage is more dangerous than continuous alternative voltage for the insulating performance of AC induction motor. This paper has investigated PD characteristics caused by impuse voltage for stator coils inserted in AC induction motor.

  • PDF

Switching Filter based on Noise Estimation in Random Value Impulse Noise Environments (랜덤 임펄스 잡음 환경에서 잡음추정에 기반한 스위칭 필터)

  • Bong-Won, Cheon;Nam-Ho, Kim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2023
  • With the development of IoT technologies and artificial intelligent, diverse digital image equipments are being used in industrial sites. Because image data can be easily damaged by noise while it's obtained with a camera or a sensor and the damaged image has a bad effect on the process of image processing, noise removal is being demanded as preprocessing. In this thesis, for the restoration of image damaged by the noise of random impulse, a switching filter algorithm based on noise estimation was suggested. With the proposed algorithm, noise estimation and error distraction were carried out according to the similarity of the pixel values in the local mask of the image, and a filter was chosen and switched depending on the ratio of noise existing in the local mask. Simulations were conducted to analyze the noise removal performance of the proposed algorithm, and as a result of magnified image and PSNR comparison, it showed superior performance compared to the existing method.

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

Electrical Breakdown Characteristics of N2 Gas under Impulse Voltages (임펄스전압에 대한 N2가스의 절연파괴특성)

  • Shin, Hee-Kyoung;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2011
  • This paper aims to examine the possibility of using an environmentally friendly $N_2$ as an alternative gas to $SF_6$. For this purpose, we have investigated breakdown characteristics of $N_2$ under impulse voltages in a quasi-uniform electric field gap. The 1.2/50[${\mu}s$] lightning impulse voltage, switching impulse voltages and oscillatory impulse voltages were applied at the test gap. The electric field utilization factor ranges from 0.5 to 0.8. The experimental data of $SF_6$ and $N_2$ acquired in the same experimental condition are presented in parallel for comparison. As a result, the breakdown voltages in $SF_6$ and $N_2$ are linearly increased with the gas pressure, also the breakdown voltages in $N_2$ are increased with increasing the gap distance and electric field utilization factor. The positive breakdown voltages are higher than the negative breakdown voltages. The nagative basic lightning impulse withstand level of 150[kV] in $N_2$ of about 0.5[MPa] is nearly equal to that in $SF_6$ of 0.15[MPa]. It is seen from the results obtained in this work that $N_2$ can be used as an eco-friendly alternative gas to $SF_6$ in distribution power equipment.

A Study on the Time-Frequency Analysis of Transient Signal using Wavelet Transformation (Wavelet 변환을 이용한 과도신호의 시간-주파수 해석에 관한 연구)

  • 이기영;박두환;정종원;김기현;이준탁
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.219-223
    • /
    • 2002
  • Voltage and current signals during impulse tests on transformer are treated as non-stationary signals. A new method incorporating signal-processing method such as Wavelets and courier transform is proposed for failure identification. It is now possible to distinguish failure during impulse tests. The method is experimentally validated on a transformer winding. The wavelet transforms enables the detection of the time of occurrence of switching or failure events. After establishing the time of occurrence, the original waveform is split into two or more sections. The wavelet transform has ability to analysis the failure signal on time domain as well as frequency domain. Therefore, the wavelet transform is superior than courier transform to analysis the failure signal. In this paper, the fact was proved by real data which was achieved.

  • PDF

A Study on the Deterioration Progress of Railway Arresters (철도용 피뢰기의 열화진전에 관한 연구)

  • 길경석;한주섭;한문섭
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.307-311
    • /
    • 2004
  • Arresters are the best protective device on electrical power systems against transient overvoltages generated by lightning and/or switching operation. Nonetheless, arresters are deteriorated by absorption of moisture in the environments of its use, repetition in the protective operation to overvoltages, and some defects at manufacturing. It is therefore important to estimate the electrical characteristic changes of ZnO blocks. In this paper, an accelerated ageing test by a standard lightning impulse current was carried out to extract parameters needed for arrester diagnosis, and leakage current components were measured. Total energy applied to the ZnO blocks at each time is about 1,050[J] in 8/20[${\mu}\textrm{s}$] impulse current. From the experimental results, we proposed electrical parameters and leakage current level to diagnose arrester soundness.

A Study on Modified Adaptive Median Filter for Impulse Noise Removal (임펄스 잡음 제거를 위한 변형된 적응 메디안 필터에 관한 연구)

  • Long, Xu;An, Young-Joo;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.804-806
    • /
    • 2014
  • During the transmission process of processing of image, various noises are added causing an error to the image. In order to restore these images, methods such as alpha trimmed average filter, standard median filter and switching median filter were proposed but such previous methods has insufficient noise suppression characteristics. Therefore in this paper, in order to remove the impulse noise added to the image, an adaptive median filter algorithm modified to expand the mask according to the noise density of mask pixels was proposed.

  • PDF

An Analysis of the Ground Surface Potential Rise and Hazardous Voltages Caused by Impulse Currents (임펄스전류에 의한 대지표면전위상승 및 위험전압의 분석)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Choi, Jong-Hyuk;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.117-123
    • /
    • 2011
  • Lightning and switching surges propagating through the grounding conductors lead to transient overvoltages, and electronic circuits in information technology systems are very susceptible to damage or malfunction from the electrical surges. Surge damages or malfunctions of electrical and electronic equipment may be caused by potential rises. To solve these problems, it is very important to evaluate the ground surface potential rises and hazardous voltages such as touch and step voltages at or near the grounding systems energized by electrical surges. In this paper, the performance of grounding systems against the surge current containing high frequency components on the basis of the actual-sized tests is presented. The ground surface potential rises and hazardous voltages depending on impulse currents for vertical or horizontal grounding electrodes are measured and analyzed. Also the touch and step voltages caused by the impulse currents are investigated. As a result, the ground surface potential rises, the touch and step voltages near the grounding electrodes are raised and the conventional grounding impedances are increased as the front time of the injected impulse currents is getting faster.

Impulse Response Characteristics of the Grounding Systems with respect to the Common-Connection Position in Power Utility System (수변전설비에서 접지시스템의 공결점의 위치에 따른 임펄스 응답특성)

  • Lee, B.H.;Eom, J.H.;Kim, S.W.;Shim, P.S.;Lee, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2149-2151
    • /
    • 1999
  • This paper describes the impulse response characteristics of the grounding systems in power utility system. Several regulations regarding to electric power equipments, services and managements require that the groundings of class 1 ($E_1$) and class 2 ($E_2$) must be connected at the common point in grounding systems. In addition, the grounding for arrester ($E_{LA}$), which belongs to the grounding of class 1, should be connected at the same point. However, there is no method and position of common-connection at anywhere. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations measuring and analyzing potential rises induced at the common connection point and other grounding conductors were conducted. The experiments were carried out in the conditions of the grounding conductor of 25m long and the near or remote common connection from ground electrode. The lightning impulse current was applied so as to simulate the on-set of arrester due to lightning and/or switching surges.

  • PDF