• Title/Summary/Keyword: Switching Impulse

Search Result 83, Processing Time 0.026 seconds

Image Restoration Algorithm using Weighted Switching Filter for Remove Random-Valued Impulse Noise (랜덤 임펄스 잡음을 제거하기 위한 가중치 스위칭 필터를 이용한 영상 복원 알고리즘)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2020
  • In the modern society, the use of digital equipment is increasing along with the 4th industrial revolution, and the importance of image and signal processing is increasing. At the same time, research on noise reduction is being actively conducted. In this paper, we propose a switching filter algorithm for random-valued impulse noise cancellation. The proposed algorithm obtains the threshold value by determining the noise level present in the image, and threshold value is compared with the difference between the input pixel value and the reference value, and is used in the weight switching process of the filter. The final output of the filter is estimated by applying a pixel weight and a modified weight median filter according to the switching, and obtains a final output by comparing the estimated value with the input pixel value. To evaluate the performance of the proposed algorithm, we compared it with the existing methods using simulation and PSNR.

Analyzing Consumer Behavioral Characteristics with Sales Promotion Orientation: Differences in Shopping and Promotion Usage Behaviors (판촉지향성에 따른 의류상품 쇼핑관련행동과 판촉이용행동)

  • 이영미;박경애
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.4
    • /
    • pp.45-56
    • /
    • 2003
  • The purpose of this study was to segment consumers based on sales promotion orientation and examine the differences between the consumer segments on shopping behaviors and promotion usage behaviors. A total of 462 responses collected from a questionnaire survey to subjects aged over 20s were analyzed. Cluster analysis on sales promotion orientation identified four groups including rational group(21%), active group(28%), insensitive group(22.1%), and interest group(28.9%) of sales promotion. ANOVA revealed significant differences among the four groups on shopping behaviors(information seeking, store visit, and clothing purchase) and promotion usage behaviors(the usage level of sales promotion, impulse buying, brand switching, and store switching). The active and interest groups were more actively seeking information than the other two groups were. The active group was most affected by sales promotion showing the highest impulse buying and brand and store switching behaviors, and the interest group was most active on store visit and clothing purchase. The insensitive group was the least engaged in all the behaviors.

Implementation of DS-UWB Impulse Generator with Suppression of Frequency Band for WLAN (WLAN 주파수 대역이 억제된 DS-UWB 임펄스 생성기 구현)

  • Park, Chong-Dae;Kim, Bum-Joo;Kim, Dong-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • In this paper, Gaussian impulse generator for DS-UWB was proposed and fabricated so that the frequency band allocated to WLAN, around 5 GHz, was suppressed in accordance with the regulation of radiation spectrum limitation defined by FCC. In order to transform an unipolar rectangular signal to a Gaussian impulse, the proposed impulse generator consists of two stage impulse generation parts; the first stage using dual SRD and the second stage using gain switching of semiconductor laser diode. The result shows a gaussian impulse as narrow as 180 psec in width. In addition, high order derivative Gaussian filter with a structure of 4 stage ring resonators was designed and fabricated so that DS-UWB impulse generator could reduce the frequency spectrum of WLAN by 25 dB compared to the spectral power of th adjacent UWB band.

  • PDF

Impulse Characteristics of MOV Elements for Railroad Vehicle Arrester (전철 탑재 피뢰기용 MOV 소자 임펄스 특성)

  • Han, S.W.;Cho, H.G.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1529-1531
    • /
    • 1999
  • The main functions of AC railroad vehicles arresters is to protect the main transformer from lightening impulse or switching impulse surge, then the MOV(metal oxide varistor) elements rated of 10kA is applied. The residual voltage and surge energy absorption are important parameters in designing arrester, these must be carefully decided with considering protecting level of impulse environment of system. The purpose of this study is to discuss the residual voltages and the energy absorption capability by impulse currents on MOV elements for railroad vehicles, and to introduce design factors which act as optimal protecting condition against impulse currents.

  • PDF

Electrical Characteristics of ZnO Varistor for Transmission Class Arrester (송전급 피뢰기용 ZnO 바리스터 소자의 전기적 특성)

  • Kim, Seok-Sou;Park, Choon-Hyun;Cho, I-Gon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.179-182
    • /
    • 2004
  • ZnO varistor for transmission class arrester$({\Phi}65{\times}20mm)$ of 10kA(Class 3) grade was recently developed in korea and is tested for the properties by switching surge operating duty test to know the line discharge class and complex surge property in electric properties. To find out changing rate of residual voltage before and after lightning impulse residual voltage testing, the sample is cool to room temperature after finishing switching surge operating duty test, and the rate is good as 1.0~1.7%. The element had been considered as applicable ZnO varistor for electricity transmission from the test results of state conterl, switching surge operating duty, thermal stability and above test. But various test should be required for actual application because this is a part of the to be needed for application.

  • PDF

A Mixed Nonlinear Filter for Image Restoration under AWGN and Impulse Noise Environment

  • Gao, Yinyu;Kim, Nam-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.591-596
    • /
    • 2011
  • Image denoising is a key issue in all image processing researches. Generally, the quality of an image could be corrupted by a lot of noise due to the undesired conditions of image acquisition phase or during the transmission. Many approaches to image restoration are aimed at removing either Gaussian or impulse noise. Nevertheless, it is possible to find them operating on the same image, which is called mixed noise and it produces a hard damage. In this paper, we proposed noise type classification method and a mixed nonlinear filter for mixed noise suppression. The proposed filtering scheme applies a modified adaptive switching median filter to impulse noise suppression and an efficient nonlinear filer was carried out to remove Gaussian noise. The simulation results based on Matlab show that the proposed method can remove mixed Gaussian and impulse noise efficiently and it can preserve the integrity of edge and keep the detailed information.

A Study on the Step Reaponse Characteristics in Shunt for Switching Impulse current (충격전류 측정용 shunt의 직각파 응답특성에 관한 연구)

  • Kim, I.S.;Jeon, J.Y.;Choi, J.G.;Mun, I.W.;Lee, D.J.;Shin, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2132-2134
    • /
    • 2000
  • Since surge arresters are recommended to protect the electric power system from the lighting surge, the impulse current is generally used to verify this requirement at the test labotaries. Recently, the international standard(IEC 60060-2) related to the impulse current techniques revised requiring a traceability of measuring system for impulse current measurements. In this paper, a shunt for impulse current is developed satisfing the revised IEC standard and the possibility of application has been investigated using step response.

  • PDF

Intercomparison Tests of National Standard Measuring System for Switching Impulse Voltage rated 500 kV (500 kV 개폐충격전압시스템의 비교시험)

  • Kim, I.S.;Kim, M.K.;Jeong, J.Y.;Moon, I.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.261-263
    • /
    • 2003
  • This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with CSIRO of Australia. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.

  • PDF

Review of the tracebility of impulse voltage measuring system in test laboratory (시험소 충격전압 측정시스템의 소급성검토)

  • Heo, J.C.;Choi, I.S.;Jeong, J.Y.;Ban, S.G.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1632-1634
    • /
    • 2003
  • For lihgtning and switching impulse voltage performances in laboratories, impulse voltage measuring system, which is consisted of voltage divider, recording instrument and connecting system between divider and recording instrument, is used. In order to show reliability of test result in test laboratory, tracebility of these measuring system to be using in test laboratory is needed. In this paper, we describe tracebility and uncertainty of impulse voltage measuring system in test laboratory.

  • PDF

Features of Transient Overvoltages Observed at 22.9kV Consumer's Substation (22.9kV 수전설비에서 측정된 과도과전압의 특성)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.52-59
    • /
    • 2014
  • The aims of this paper are to characterize the transient overvoltages(TOVs) and to evaluate the risk occurring at 22.9kV consumer's substation. The measurements of lightning- and switching-caused TOVs were made during Mar. 2013 and Feb. 2014. As a consequence, 47 events of TOVs were recorded and 4 of them were higher than the input voltage envelope(IVE) of the information technology industry council(ITI) curve. The measured TOVs are characterized by longer front times and longer durations compared to the $1.2/50{\mu}s$ standard impulse voltage waveform, and some of them represent bipolar waves with lower oscillation frequencies. It suggests that the test of non-standard impulse voltage waveforms is needed for effective risk assessments of power apparatus. Lightning- and switching-caused TOVs exceeding IVE of ITI curve are induced at the secondary of 22.9kV potential transformer(PT). We may, therefore, conclude that the surge protection devices should be applied at the secondary of PT and the surge absorbers should be installed at the primary of VCB or PT. The results presented in this paper could be useful to design the reasonable insulation coordination for 22.9kV consumer's substation.