• Title/Summary/Keyword: Switching Flow

Search Result 251, Processing Time 0.025 seconds

Cooling characteristics of the telecommunication system in a switching room for various air supply and return flow system (교환기실의 급배기방식에 따른 통신 시스템의 냉각 특성)

  • 노홍구;이재헌;고철균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.669-683
    • /
    • 1999
  • Heat dissipation in the domestic switching room has been gradually increased. Therefore, numerical study on the cooling characteristics of the telecommunication system in a switching room for three kinds of the air supply and return flow system was investigated to develop effective flow system. As a result, the cooling performance of the under floor air supply and overhead return flow system was the best.

  • PDF

A Study on the Dynamic Flow Classification for IP Switching (IP 스위칭에서 동적 흐름 분류에 관한 연구)

  • 이우승;정운석;박광채
    • Proceedings of the IEEK Conference
    • /
    • 2000.06c
    • /
    • pp.169-172
    • /
    • 2000
  • IP Switching is a new routing technology proposed to improve the performance of IP routers. Flow classification is one of the key issues in IP Switching. To achieve better performance, flow classification should be matched to the varying IP traffic and an IP switch should make use of its hardware switching resources as fully as possible. This paper proposes an adaptive flow classification algorithm for IP Switching. By dynamically adjusting the values of its control parameters in response to the present usage of the hardware switching resources, this adaptive algorithm can efficiently match the varying IP traffic and thus improve the performance of an IP switch.

  • PDF

The Dynamic Flow Classification Method According to the VC Usage in IP Switching (IP 스위칭에서 VC 사용량에 따른 동적 흐름 분류 방법)

  • 박세환;박광채
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.73-79
    • /
    • 2001
  • IP Switching is a new routing technology Proposed to improve the Performance of IP routers. Flow classification is one of the key issues in IP Switching. To achieve better performance, flow classification should be matched to the varying IP traffic and an IP switch should make use of its hardware switching resources as fully as possible. This paper proposes an dynamic flow classification method for IP Switching. By dynamically adjusting the values of its control parameters in response to the present usage of the hardware switching resources, this dynamic method can efficiently match the varying IP traffic and thus improve the performance of an IP switch.

  • PDF

Operation Limit of Flow Control for a Bistable Fluidic Valve

  • Lee, Ji Ung;Hong, Ji-Seok;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.389-394
    • /
    • 2017
  • The limitation of flow control for a bistable fluidic valve has been investigated. The physical model of the fluidic valve includes two main flow outlets and two control flow inlets. The experiments were conducted with pressure regulators, mass flow meters, and piezo sensors to analyze flow switching characteristics of the fluidic valve. The experimental data such as pressure and mass flow rate of control flows and the switching time of the main flow was obtained with various operating conditions. The operation limit of the fluidic valve is identified, and a model equation for pre-estimating the minimum control pressure to switch the direction of the main flow has been proposed.

Simulation of Liquid Crystals Considering Flow Effect (흐름효과를 고려한 액정의 시뮬레이션)

  • Kim Hoon;Park Woo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.3
    • /
    • pp.260-266
    • /
    • 2006
  • In this paper, We coupled fluid balance and director balance equation from Ericksen-Leslie's continuum theory and observed the motion of Liquid Crystal molecular. We simulated flow velocity and director distribution in which flow effect is considered in switching on and switching off state. We interpreted the dynamic response characteristic caused by the flow. As the result of the simulation, We could see the flow effect. In the case of Twisted Nematic(TN) cell, this flow caused abnormal twist temporarily in switching off state. We could prove that this abnormal twist is a direct cause of optical bounce phenomenon known well until now with the result of simulation. In addition, We analyzed the mechanism of the fast response due to flow in the case of Optically Compensated Bend(OCB) cell.

A 48V-400V Non-isolated Bidirectional Soft-switching DC-DC Converter for Residential ESS (PPS 제어기법을 적용한 48V-400V 비절연 양방향 DC-DC컨버터)

  • Jeong, Hyeon-Ju;Kwon, Min-Ho;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.190-198
    • /
    • 2018
  • This paper proposes a nonisolated, bidirectional, soft-switching DC - DC converter with PWM plus phase shift (PPS) control. The proposed converter has an input-parallel/output-series configuration and can achieve the interleaving effect and high voltage gains, resulting in decreased voltage ratings in all related devices. The proposed converter can operate under zero-voltage switching (ZVS) conditions for all switches in continuous conduction mode. The power flow of the proposed converter can be controlled by changing the phase shift angle, and the duty is controlled to balance the voltage of four high voltage side capacitors. The PPS control device of the proposed converter is simple in structure and presents symmetrical switching patterns under a bidirectional power flow. The PPS control also ensures ZVS during charging and discharging at all loads and equalizes the voltage ratings of the output capacitors and switches. To verify the validity of the proposed converter, an experimental investigation of a 2 kW prototype is performed in both charging and discharging modes under different load conditions and a bidirectional power flow.

A Study on the Efficient Label Management Methods in High-Speed IP Switching Networks (고속 IP 교환망에서 효율적인 레이블 관리 방식에 관한 연구)

  • Shim, Jae-Hun;Chang, Hoon
    • The KIPS Transactions:PartC
    • /
    • v.11C no.4
    • /
    • pp.527-538
    • /
    • 2004
  • In this paper, we present the flow aggregation method and the FLTC(flow lasting time control) algorithm to reduce the number of flows and solve the scalability problem in high speed IP switching networks. The flow aggregation based on the destination address could reduce the total number of flows, improve the label efficiency, and increase the total amount of the switched packets. The FLTC algorithm also eliminates the waste of label by deleting the flow binding efficiently. With the traces of real Internet traffics, we evaluate the performance of these schemes by simulation. The label efficiency, the average number of label used, and the percentage of packets switched and the number of packets switched are used as performance measures for this simulation.

A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter (양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법)

  • Song, Y.J.;Park, S.I.;Jeong, H.G.;Han, S.B.;Jung, B.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF

Cache Table Management for Effective Label Switching (효율적인 레이블 스위칭을 위한 캐쉬 테이블 관리)

  • Kim, Nam-Gi;Yoon, Hyun-Soo
    • Journal of KIISE:Information Networking
    • /
    • v.28 no.2
    • /
    • pp.251-261
    • /
    • 2001
  • The traffic on the Internet has been growing exponentially for some time. This growth is beginning to stress the current-day routers. However, switching technology offers much higher performance. So the label switching network which combines IP routing with switching technology, is emerged. EspeciaJJy in the data driven label switching, flow classification and cache table management are needed. Flow classification is to classify packets into switching and non-switching packets, and cache table management is to maintain the cache table which contains information for flow classification and label switching. However, the cache table management affects the performance of label switching network considerably as well as flowclassification because the bigger cache table makes more packet switched and maintains setup cost lower, but cache is restricted by local router resources. For that reason, there is need to study the cache replacement scheme for the efficient cache table management with the Internet traffic characterized by user. So in this paper, we propose several cache replacement schemes for label switching network. First, without the limitation at switching capacity in the router. we introduce FIFO(First In First Out). LFC(Least Flow Count), LRU(Least Recently Used! scheme and propose priority LRU, weighted priority LRU scheme. Second, with the limitation at switching capacity in the router, we introduce LFC-LFC, LFC-LRU, LRU-LFC, LRU-LRU scheme and propose LRU-weighted LRU scheme. Without limitation, weighted priority LRU scheme and with limitation, LRU-weighted LRU scheme showed best performance in this paper.

  • PDF

A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods (수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Park, Cha-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.605-611
    • /
    • 2012
  • The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.