• Title/Summary/Keyword: Sustained interruption

Search Result 10, Processing Time 0.024 seconds

Evaluation of Reliability Worth Considering Sustained Interruptions and Voltage Sags (영구정전과 순간전압강하를 고려한 신뢰도 비용 평가)

  • Lee, Hee-Tae;Moon, Jong-Fil;Seol, Kyu-Hwan;Yun, Sang-Yun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.13-20
    • /
    • 2008
  • Power quality problems such as momentary interruptions and voltage sags do not great influence on loads at past. However, the interests in power quality problems increase as the use of sensitive loads with microprocessor like computers increases recently. Accordingly, power system reliability research focusing to sustained interruption and momentary interruption partially needs more accurate evaluation methods including momentary and instantaneous problems. That is, many sensitive loads being tripped by voltage sags result in interruption costs. In this paper, new reliability worth evaluation method is presented considering voltage sags. We calculated the magnitude of voltage sags using fault studies and the duration of voltage sags using the trip time of protective relays for each fault. Moreover, we includes the customer interruption cost resulted from sensitive load trip by voltage sags. Through case studies, we evaluate the effects of voltage sags for permanent faults.

A Comparative Study for Reliability of Single and Radial Power Distribution System considering Momentary Interruption (단일루프 배전계통과 방사상 배전계통의 순간정전을 고려한 신뢰도 비교 연구)

  • Lee, Hee-Tae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1270-1275
    • /
    • 2009
  • The structure of a power distribution system will change in a loop configuration such as in the case of a smart grid. If power distribution system changes radial to loop form, the structure may have to be changed significantly. Therefore, we analyzed the reliability indices and calculated a CIC(Customer Interruption Cost) for the loop power distribution system. The power distribution system reliability depends on the protection scheme. This study is applied to the current protection scheme method and is compared with each model. When the CIC was evaluated, most studies performed calculations only for sustained interruptions. However, in actuality, momentary interruption frequencies occurred more than sustain interruptions. Thus, it is occurred the CIC additively. Therefore, we evaluated a CIC including momentary interruption, for each model, and then compared with MAIFI(Momentary Average Interruption Frequency Index)

Power Interruption Cost Calculation based on Value-based Methodology (가치평가법을 사용한 정전관련비용의 산정)

  • Lee, Buhm;Kim, Kyoung-Min;Choi, Nam-Sup
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.293-300
    • /
    • 2021
  • This study presents a Power Quality(:PQ) costs calculation methodology based on Value-Based Methodology. A SCDF including Voltage Sag Costs is presented to calculate Sustained Interruption Costs, Momentary Interruption Costs, and Voltage Sags Costs. Authors compared between interruption costs without Back-Up Power Supply and interruption costs with Back-Up Power Supply, and showed reduction of interruption costs by investing Back-UP Power Supply by multi-lateral analyzation. By applying this method to the real system, evaluated and analyzed power quality of the system.

Reliability Evaluation for Considering the Voltage Quality in Power Distribution Systems (전압품질을 고려한 배전계통의 신뢰도 평가)

  • Yun, Sang-Yun;Kim, Oun-Seok;Bae, Joo-Chun;Kim, Nark-Kyung;Park, Joong-Shin;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.525-527
    • /
    • 2000
  • This paper presents a reliability evaluation method for considering the voltage quality. The proposed evaluation methods are contained the sustained interruption, momentary interruption and voltage sag. For momentary interruption, evaluation indexes are divided the duration based index and the interruption cost index. For voltage sag, the final result of evaluation method represents the magnitude for customers' risk due to the voltage sag. The proposed method is tested using the RBTS model and a reliability data in KEPCO's system.

  • PDF

An Improved Investment Priority Decision Mettled for the Electrical Facilities Considering the Reliability of Distribution Networks (배전계통 신뢰도를 고려한 전기설비투자 우선순위 결정 기법)

  • Park Chang-Ho;Chae Woo-Kyu;Jang Sung-Il;Kim Kwang-Ho;Kim Jae-Chul;Park Jong-Keun;Choi Jung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.177-184
    • /
    • 2005
  • This paper proposes a improved investment priority decision method of the facilities considering the reliability of distribution networks. The proposed method decides a investment order of the facilities combining, by fuzzy rules, the investment priority decision of KEPCO and the priority decision considering reliability evaluation indices. Where reliability evaluation indices are SAIFI(System Average Interruption Frequency Index) and SAIDI(System Average Interruption Duration Index), as referred to evaluation index for sustained interruption. The reliability analysis method of distribution networks applied in this paper utilizes analytic method, where the used reliability data is historical data of KEPCO. Particularly, we assumed that the failure rate increased as the equipment ages. To verify the performance of the proposed method, we applied it with the planned projects to reinforce the weak facility electrical facilities in KEPCO in 2004. The evaluation result showed that, under a limited budget, the reliability of the KEPCO in the Busan region using the proposed method can be enhanced than using the conventional KEPCO's method. Therefore, the results verify the proposed method can be efficiently used in the actual priorities method for investing the electrical facilities.

Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse (고온 초전도 퓨즈의 한류 및 방전 특성)

  • Choi, Hyo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.673-677
    • /
    • 2004
  • We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.

A Study on harmonics generation and reduction in Dimmer circuits (Dimmer 회로에서의 고조파 발생과 저감에 관한 연구)

  • Park, Seok-Hoon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.252-254
    • /
    • 2000
  • For many years, electric utility has used sustained interruption rates as a reliability index. Today, however, many electricity consumers are adversely affected by more subtle voltage disturbances such as harmonic distortion. This paper deals with observations of events that occur in the Dimmer circuits and phase control which could affect harmonics problem to the commercial power system. In order to reduce the effect of harmonics and design filters, Solid State Relay Dimmer(SCRs or TRIACs) and Noise Filter are described, and the effects of harmonics is also analyzed. IGBT Dimmer which is appropriate method to reduce harmonics and improve efficiency is introduced.

  • PDF

Total Cavo Pulmonary Shunt: Report of two cases (총대정맥-폐동맥 단락술 수술치험 2례)

  • Park, Cheol-Hyeon;Lee, Sin-Yeong;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1263-1269
    • /
    • 1990
  • Two patients with uncorrectable cyanotic cardiac anomalies underwent total cavopulmonary shunt[modified Fontan operation]. Case I was a 14 years old male with dyspnea and cyanosis after birth. Aortogram showed TGA combined with overriding of aorta, pulmonary stenosis, complete atrioventricular septal defect, interruption of inferior vena cava, and situs inversus totalis. We had performed total cavopulmonary shunt using with 16 mm Gortex Graft in single atrium to bypass the hepatic vein to pulmonary artery. Postoperatively, patient sustained low PaCO2 and low cardiac output and then expired at 19th postoperative day. The cause of death of the patient would be low cardiac output. Case II was a 6 years old female with dyspnea and cyanosis after birth. Aortogram showed tricuspid atresia[Type IIb], transposition of great arteries, atrial septal defect, ventricular septal defect and pulmonary stenosis, We had performed total cavo-pulmonary shunt using intraatrial baffle[tunnel] with Goretex patch. The postoperative course of this patient was good without event.

  • PDF

Operation properties of high $T_c$ superconductive current limiting fuse (고온 초전도 한류퓨즈의 동작특성)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Park, Kwon-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.67-68
    • /
    • 2001
  • We present the basic properties of a superconductive current limiting fuse (SCLF) based on YBCO/Au films. The SCLF consists of meander type YBCO stripes covered with an Au layer for current shunt. The fault current was first limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enables the SCLF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption.

  • PDF

The characterization of a Superconductive Current Limiting Fuse (초전도 한류퓨즈의 특성연구)

  • Choi, Hyo-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.318-320
    • /
    • 2004
  • We investigated the basic properties of a superconductive current limiting fuse (SCLF) based on YBCO/Au films. The SCLF consists of meander type YBCO stripes covered with an Au layer for current shunt. The fault current was first limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enables the SCLF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption.

  • PDF