• Title/Summary/Keyword: Suspended Concentration

Search Result 880, Processing Time 0.031 seconds

A Study on Design of Containment Area Considering Suspended Solid Sedimentation (부유물 침전을 고려한 준설투기장 설계에 관한 연구)

  • Jee, Sunghyun;Huh, Byungjoo;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.57-63
    • /
    • 2010
  • For optimum scale design of containment area, a series of laboratory tests using column were performed in this study as followings; sedimentation test and self-weight consolidation test for dredged soil, and suspended solid concentration test for supernatant. Containment area has been designed and evaluated, based on field condition and concentration of suspended solid of effluent water. In addition, the relation between width of containment area and target concentration of suspended solid was analyzed. The results show that concentration of suspended solid decreases as the width of containment area decreases and the length of containment area increases. It was also observed that influence of change in ponding depth should be considered to predict the change in suspended solid concentration in supernatant discharged as disposal is conducted; the lower target suspended solid concentration of effluent water, the more important.

An Efficient Method Of The Suspended Sediment-Discharge Measurement Using Entropy Concept

  • Choo, Tai-Ho
    • Water Engineering Research
    • /
    • v.1 no.2
    • /
    • pp.95-105
    • /
    • 2000
  • A method is presented which enables easily the computation of the suspended sediment discharge as the mean sediment concentration and mean flow velocity. This method has significant advantages over the traditional method, which principally depend on a set of measured concentration data. The method is based on both a new sediment concentration and mean sediment concentration equations which have been derived from the entropy concept used in statistical mechanics and information theory: (1) The sediment concentration distribution equations derived, are capable of describing the variation of the concentration in the vertical direction. (2) The mean concentration equation derived, is capable of calculating easily the mean concentration by using only one measured concentration in open channel. The present study mainly addresses the following two subjects : (1) new sediment concentration and mean sediment concentration equations are derived from the entropy concept : (2) An efficient and useful method of suspended sediment-discharge measurements is developed which can facilitate the estimation of suspended sediment-discharge in open channel. Flume and laboratory data are used to carry out the research task outlined above. An efficient method for determining the suspended sediment-discharge in the open channel has been developed. The method presented also is efficient and applicable in estimating the sediment transport in rivers and the sediment deposit in the reservoirs, and can drastically reduce the time and cost of sediment measurements.

  • PDF

A Direct Inversion Method to Remotely Measure the Concentration Profile of Suspended Sediment Using Acoustic Backscatterance

  • Lee, Tae-Hwan
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.48-50
    • /
    • 1995
  • The use of acoustics to measure the concentration profile of suspended sediment become increasing common. Field studies have shown the usefulness of remotely measuring the suspended sediment concentration with high spatial and temporal resolution. Techniques that allow for the conversion of the backscattered acoustic intensity into suspended sediment concentration have been developed concurrent with instrumentation. (omitted)

  • PDF

Distribution and Behaviors of In-Situ Suspended Particulate Matters of Gwangyang Bay (광양만내의 현장 부유입자물질 분포와 거동)

  • Lee, Byoung-Kwan;Kim, Seok-Yun;Cho, Hyun-Man
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.99-105
    • /
    • 2010
  • The concentration and size analysis of in-situ suspended particulate material were measured using an optical instrument, LISST-100, in the bottom layer at the three inlets of the Seomjin River Estuary, mouth of Gwangyang bay, and Gwangyang bay-side of the Namhae Bridge. In the Seomjin river estuary and mouth of Gwangyang bay-side of the Namhae Bridge, the in-situ mean grain size of the suspended material changed from a uni-modal distribution with a dominant peak at a coarse fraction to a bi-modal distribution with a secondary peak at the finer particles. Seomjin River. The interactions between suspended particulate concentration and beam attenuation coefficient of suspended particulate matters depended on the supply of finer and coarser particles in the mouth of Gwangyang Bay and Seomjin River. So, interactions reflected difference of the concentration, mean size and sorting of suspended particulate matters. The difference of interaction showed dynamic behaviors to the resuspension and deflocculation processes increased river discharge. This showed that it may be possible to use the interactions between the suspended particle concentration and beam attenuation coefficient to monitor the temporal and spatial distributions of in-situ particles.

Characteristic of In Situ Suspended Particulate Matter at the Gwangyang bay Using LISST-100 and ADCP (LISST-100과 ADCP를 이용한 광양만 현장 부유입자물질 특성 연구)

  • Lee, Byoung-Kwan;Kim, Seok-Yun
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1299-1307
    • /
    • 2009
  • In order to measure in-situ suspended particle size, volume concentration of suspended particulate matter and current speed, mooring observation was performed at the Gwangyang Bay by using of an optical instrument, 'LISST-100' and an acoustic instrument, 'ADV'(St. S1). And the sediment flux was obtained based on the concentration of suspended particulate matter and current speeds measured at three lines of Gwangyang Bay during ebb and flood tide of August 2006. To investigate the spatial variation of suspended particulate matter, profiling observations were measured difference echo intensity and beam attenuation coefficient by using of ADCP and Transmissometer (Line A, B, C). The suspended sediment flux rate at the mouth of Gwangyang Bay was observed to be higher during asymmetrical than symmetrical of current speeds. The flux of suspended particulate matter concentration and current speeds were transported to southeastern direction of surface layer and northwestern direction of bottom layer at the western area at line A of Gwangyang Bay. Small suspended particles have been found to increase attenuation and transmission more efficiently than similar large particles using acoustic intensity (ADV/ADCP) or optical transmit coefficient (LISST-100/Transmissometer). The application and problems as using optical or acoustic instruments will be detected for use in time varying calibrations to account for non-negligible changes in complex environments in situ particle dynamics are poorly understood.

Suspended Particulate Concentration at the Drilling Site of Underground Coal Mines in Taebaek Area (태백지역 석탄광업 굴진부서의 부유분진 농도)

  • 윤영노;김영식;이영신
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.32-38
    • /
    • 1991
  • Airborne suspended particulate concentration in drilling sites of underground coal mines in Taebaek area was evaluated. And respirable coal dust exposure level was evaluated. Airborne suspended particulate mass include total suspended particle(TSP) and thoracic particle(TPM). TSP (by open-face filter holder) and TPM(by elutriator) concentration were determined by low volume air samplers. Personal air samplers were attached to the coal workers including drillers, coal cutters, and their assistants. Normality and log-normality of TSP, TPM, and respirable dust(RPM) concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of TSP, TPM, and RPM concentration were tested by paired t-test. Relation between TSP, TPM, and RPM with pairs were tested by regression test and Pearson's correlation.

  • PDF

A Study on the Vertical Distributions of the Concentration in Suspended Sedimentations (부유유사의 연직농도분포에 관한 연구)

  • 유시창;김희종
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.4
    • /
    • pp.80-91
    • /
    • 1982
  • To precict the suspended sediments which are 80% of total sediments in a flood disch- arge, an equation representing vertical distribution of sediment concentration was derived based upon the diffusion theory and the logalithmic velocity distribution function in the tubulent flow mechanism. The hypothesis that the uniform mass transfer is occurred at upper part along the center line of water depth, was established as a preconition to solve the problem. The theorecal and the observed values were compared. And the theoretical equation was modified to be fit the theoretical values the observed values. Observed results are as follow; 1) Equation 12) is the theoretical equation representing the vertical concentration distri- bution of suspended sedimenta 2) Rous&exonential type vertical concentration distribution equation shows signification errors near the water surface. But the equation 12) shows substation cocentration values near the water surface. 3) Equation 15) is the modified theoretical equation which is possible to predict the vertical concentration distribution of suspended sediments.

  • PDF

Particle Size Distribution of Suspended Particulates in the Atmosphere of a Seoul Residential Area (한 도시 분진의 유해성 입도 분포에 대한 조사 연구)

  • Han, Eui-Jung;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.1 s.19
    • /
    • pp.130-136
    • /
    • 1986
  • The particle size of suspended particulates was measured by a Anderson air sampler from Mar. 1982 to Feb. 1984 in a part of Seoul. It was concluded as follows : 1) The arithmetic concentration of suspended particulates was $147.8{\mu}g/m^3$ in Spring, 136.9 in Summer, 131.9 in Autumn and 158.1 in Winter respectively. 2) The cumulative distribution of suspended particulates size in logarithmic diagram showed similar to normal log distribution. 3) The atmospheric particulate matters showed a bimodal size distribution on the base of unit particle concentrations, which divided at approximately $2{\mu}m$ in the diameter. 4) While the fine particulates less than $2.1{\mu}m\;was\;35.4{\sim}45.0%$, the coarse particulates was $55.0{\sim}64.5%$. 5) The higher the concentration of suspended particulates, the more increased the ratio of fine particulates. The higher the concentration of suspended particulates, the lower median size of suspended particulate as well. 6) The respirable dust particulates less than $4.7{\mu}m\;was\;52.2{\sim}62.9%$ in seasonal average through the 2 year samples. With the above result, air pollution concerned with public health could be evaluated and the control measures also are suggested.

  • PDF

The Concentration of TSP and Heavy Metals in the Indoor Air of Local PC Rooms (지방 일개도시 PC방에서의 실내공기중 TSP농도와 TSP내 중금속 농도)

  • Cha Hyun Su
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.190-200
    • /
    • 2002
  • This study was carried out to investigate and analyze TSP of the PC rooms. The concentration of the total suspended particulate and heavy metals contained in the total suspended particulate of the 15 PC rooms located in one local city were measured. The statistical correlation coefficients between the total suspended particulate and factors of the indoor condition (number of fan or size of pc room, illumination), between the heavy metals and factors of the indoor condition were studied. The results are as follows: 1. The factors of the indoor condition of the 15 PC rooms are as follows. Average illumination was 24 luxes. Average number of computers installed were 37. Average number of the fans was 7. and the size of investigated PC rooms was $139.94m^2$. 2. The mean age of the subjects was 21.8 years old. they $(51.5\%)$ used the 15 pc rooms for fewer than 2 hours per one day. 3. The mean concentration of total suspended particulate (TSP) is lower in the evening ${139.085\;(2.462)\;{\mu}g/m^3}$ than the night ${166.216(2.609){\mu}g/m^3}$. 4. The mean concentration of total suspended particulate was industrial work area) residential area) commercial area. 5. The distribution of heavy metals were indicated as Zn>Cr>Pb>Cd in the indoor air at PC rooms. and the concentration rate of Zn was the highest among heavy metals. but this increase didn't show any relationship with many factors of indoor condition (number of fan or size of pc room, lighting) 6. The concentration of TSP & heavy metals didn't have any relationship between the factors of indoor environment (number of fans, size of pc room, lighting).

  • PDF

Study on the Settling Process of Cohesive Sediment (점착성 퇴적물의 침강특성에 관한 연구)

  • Sin, Dong-Su;Bae, Gi-Seong
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.2 s.28
    • /
    • pp.111-120
    • /
    • 1998
  • Laboratory settling experiments (column, recirculating flume) were conducted for further understanding of the physical processes of cohesive sediment transport. \In still water experiments, the growth rate of flocculation is dependent upon the initial suspended concentration. Consequently, the settling velocity increases with concentration of flees. In flocculation settling regime, the exponent n in the settling velocity, $w_s=kC^n$, for Nakdong estuary mud was obtained empirically. The exponents were found to be 1.33, and 1.06 for the initial suspended concentrations of 1 g/i and 3 g/t, respectively. In flowing water, experiments for the median settling velocity with Nakdong mud in a recirculating flume were conducted. Settling velocity was found to depend much more strongly on the current velocity than initial concentrations. The temporal variation of suspended concentration increases as current velocity decreases.

  • PDF