• Title/Summary/Keyword: Surgical technology

Search Result 370, Processing Time 0.024 seconds

Vascular ring anomaly with a right patent ductus arteriosus and a left aortic arch in a juvenile cat

  • Aki Takeuchi ;Kazumi Shimada ;Lina Hamabe ;Tomohiko Yoshida;Yusuke Ozai ;Miki Hirose ;Aimi Yokoi ;Momoko Watanabe ;Ikki Mitsui ;Ryou Tanaka
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.50.1-50.6
    • /
    • 2023
  • This paper reports the clinical findings and surgical treatment of feline right patent ductus arteriosus (RPDA) with a left aortic arch. A two-month-old female Maine Coon was referred for an investigation of regurgitation after weaning. RPDA with a left aortic arch was diagnosed based on the echocardiographic and computed tomography (CT) findings. A right-fourth intercostal thoracotomy was found to be an appropriate approach to the duct. Preoperative diagnosis is crucial and diagnostic imaging, including radiography, echocardiography, and cardiac CT examination, is essential for determining if the aortic arch is right or left.

Antimicrobial Activity and Mechanism of Polyvinyl Chloride Composite Containing Inorganic Bacteriocide

  • Park, Se-Ho;Lee, Jae-Yeul;Choi, Ju-Hwan;Park, Tae-Hee;Moon, Sung-Bae;Lee, Hyeongsu;Bang, Daesuk;Yang, Seun-Ah;Jhee, Kwang-Hwan
    • Elastomers and Composites
    • /
    • v.50 no.3
    • /
    • pp.223-230
    • /
    • 2015
  • Bacterial infection is one of the most common and universal cause of disease spreading associated with medical and surgical environment. Antimicrobial function of plasticized polyvinyl chloride (PVC) will be useful for making hygienic environments. Here, we synthesized the PVC composite by the addition of inorganic bacteriocide containing silver, zinc and zeolite. And we investigated the growth inhibition rate for Staphylococcus aureus and Klebsiella pneumoniae which were analyzed in the presence of PVC composite with different doses of inorganic bacteriocide (1~15 wt%). Bacterial proliferation was significantly inhibited by 3 wt% of inorganic bacteriocide containing PVC composite. And we found the inhibition of bacterial biofilm formation by 5 wt% of inorganic bacteriocide containing PVC composite by the observation of scanning electron microscopy (SEM). Our data suggested that the antimicrobial effect of inorganic bacteriocide was caused by disturbing the bacterial biofilm formation.

Core Temperature Evaluation in Different Body Parts in Patients Undergoing Laparoscope Surgery under Total Intravenous Anesthesia (전정맥 전신마취하(下) 복강경 수술환자의 부위별 심부체온의 변화 평가)

  • Hahm, Tae Soo;Kim, Won Ho;Kim, Nam Cho;Yoo, Je Bog
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.4
    • /
    • pp.379-386
    • /
    • 2015
  • Purpose: The trend of body temperature change during laparoscopic surgery and the most adequate site for monitoring temperature measurements have not been investigated thoroughly. In this study body temperature change during laparoscopic surgery was measured and measurements of the tympanic, esophageal, and nasopharyngeal core temperatures in surgical patients with total intravenous anesthesia were compared. Methods: From February to October 2013, 28 laparoscopic surgical patients were recruited from a tertiary hospital in Seoul. The patients' core temperature was measured 12 times at ten minute intervals from ten minutes after the beginning of endotracheal intubation. Results: Repeated measure of core temperatures indicated a significant difference according to body part (p=.033), time of measure (p<.001) and the reciprocal interaction between body part and time of measure (p<.027). The core temperatures were highest at tympany location, lowest at nasopharynx. The amount of temperature change was least for the esophagus ($36.10{\sim}36.33^{\circ}C$), followed by nasopharynx and tympany. Conclusion: The esophageal core temperature showed the highest stability followed by nasopharyngeal and tympanic temperature. Therefore, close observations are required between 10~20minutes after the beginning of the operation.

ACCURACY TESTS OF 3D RAPID PROTOTYPING (RP) MEDICAL MODELS: ITS POTENTIAL AND CLINICAL APPLICATIONS (Rapid Prototyping으로 제작한 3D Medical Model의 오차 측정에 관한 연구 (임상 적용 가능성 및 사례))

  • Choi, Jin-Young;Choi, Jung-Ho;Kim, Nam-Kuk;Lee, Jong-Ki;Kim, Myeng-Ki;Kim, Myung-Jin;Kim, Yeong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.295-303
    • /
    • 1999
  • Presented in this paper are the experimental results that measure rapid prototyping (RP) errors in 3D medical models. We identified various factors that can cause dimensional errors when producing RP models, specifically in maxillofacial areas. For the experiment, we used a human dry skull. A number of linear measurements based on landmarks were first obtained on the skull. This was followed by CT scanning, 3D model reconstruction, and RP model fabrication. The landmarks were measured again on both the reconstructed models and the physical RP models, and these were compared with those on dry skull. We focused on major sources of errors, such as CT scanning, conversion from CT data to STL models, and RP model fabrication. The results show that the overall error from skull to RP is $0.64{\times}0.36mm(0.71{\times}0.66%)$ in absolute value. This indicates that the RP technology can be acceptable in the real clinical applications. A clinical case that has applied RP models successfully for treatment planning and surgical rehearsal is presented. Although the use of RP models is rare in the medical area yet, we believe RP is promising in that it has a great potential in developing new tools which can aid diagnosis, treatment planning, surgical rehearsal, education, and so on.

  • PDF

CYBERKNIFE RADIOSURGERY FOR INOPERABLE RECURRED ORAL CANCER (사이버나이프를 이용한 수술 불가능한 재발성 구강암의 치험례)

  • Kim, Yong-Kack;Lee, Tae-Hee;Kim, Chul;Kim, Sung-Jin;Kim, Hyuk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.1
    • /
    • pp.65-68
    • /
    • 2004
  • CyberKnife is a stereotactic radiosurgery system which could be used to treat many tumors and lesions. It provides the surgeon unparalleled flexibility in targeting using a compact light linear accelerator mounted on a robotic arm. Advanced image guidance technology tracks patient and target position during treatment, ensuring accuracy without the use of an invasive head frame. CyberKnife with Dynamic Tracking Software is cleared to provide radiosurgery for lesions anywhere in the body when radiation treatment is indicated. It has often been used to radiosurgically treat otherwise untreatable tumors and malformations. Moreover, this instrument treats tumors at body sites, most of which are unreachable by other stereotactic systems. Compared with conventional radiotherapy, it is fundamentally different that using non-invasive, frameless, no excessive radiation exposure to normal tissue. In oral malignant neoplasm, surgical excision and radiation therapy should be tried first, additionally chemotherapy could be considered. However, after failure of conventional therapies, patients had poor systemic condition and surgical limitation. So, CyberKnife could be a suitable therapy. A 49 years man was referred in recurred mandibular cancer treated by radiotherapy. The tumor was considered inoperable, because of extensive invasion and was not expected to good response to conventional therapies. We experienced a case of CyberKnife after 4 cycle chemotherapies, so we report it with review of literature.

Development of Portable Astral Light using the High Power 3-Color LEDs (고출력 3색 LED를 이용한 휴대용 무영등의 개발)

  • Yu, Seong-Mii;Cheon, Min-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1111-1117
    • /
    • 2011
  • We was designed the portable LED light which can shadowless shooting and developed using a high-power LED that medical attention as a new lighting components for structural confirmation of oral dental area, medical and surgical lesions in the local area. LED which applied to the development, was used the 3-color LEDs for possible of implement a variety of colors and adjusted the light intensity. It is being magnified of delicacy expressiveness and three-dimensional for tone of the subject-specific. It has been developed a highly efficient light module that LED is used to consider the electrical characteristics and optical properties. SMPS has We was designed the portable LED light which can shadowless shooting and developed using a high-power LED that medical attention as a new lighting components for structural confirmation of oral dental area, medical and surgical lesions in the local area. LED which applied to the development, was used the 3-color LEDs for possible of implement a variety of colors and adjusted the light intensity. It is being magnified of delicacy expressiveness and three-dimensional for tone of the subject-specific. It has been developed a highly efficient light module that LED is used to consider the electrical characteristics and optical properties. SMPS has produced for use in mobile that can be driven at low voltage. In addition, it was also possible to implement a variety of colors from monochromatic Light to polychromatic light using by PWM control method and were available 32,768.

Clinical Study Comparing the Skin Antiseptics of Povidone-iodine and Chlorhexidine-ethanol on Port Site (투관침 부위에 적용하는 포비돈 아이오딘과 클로르헥시딘-에탄올의 소독제 효과 연구)

  • Kang, Min Jung
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.10
    • /
    • pp.80-87
    • /
    • 2020
  • The purpose of this study was to compare in antiseptic effect between povidone-iodine and chlorhexidine-ethanol for laparoscopic cholecystectomy on the port site. A total of 46 patients admitted to surgery at one university hospital in Seoul were included in the study. A study group was randomly assigned using a random number table. The antiseptic effect was evaluated and compared to povidone-iodine and chlorhexidine-ethanol by using a culture and identification of bacteria, measurement of the number of bacteria (CFU/ml) and incidence of surgical site infection. Our results show that povidone-iodine and chlorhexidine-ethanol have no statistically significant difference in the incidence rate of bacteria after 3 minutes of disinfection and before removal of the trocar and in the number of bacteria and the incidence of surgical site infection. Thus, in order to select an efficient and appropriate skin antiseptics, we suggest that it is necessary to consider not only the disinfectant effect but also cost and convenience. In this research, our results about effect and usage of skin antiseptics can be used as basic data and educational resource, and this is expected to improve comprehension of skin antiseptics.

Maxillary protraction using customized mini-plates for anchorage in an adolescent girl with skeletal Class III malocclusion

  • Liang, Shuran;Xie, Xianju;Wang, Fan;Chang, Qiao;Wang, Hongmei;Bai, Yuxing
    • The korean journal of orthodontics
    • /
    • v.50 no.5
    • /
    • pp.346-355
    • /
    • 2020
  • The treatment of skeletal Class III malocclusion in adolescents is challenging. Maxillary protraction, particularly that using bone anchorage, has been proven to be an effective method for the stimulation of maxillary growth. However, the conventional procedure, which involves the surgical implantation of mini-plates, is traumatic and associated with a high risk. Three-dimensional (3D) digital technology offers the possibility of individualized treatment. Customized mini-plates can be designed according to the shape of the maxillary surface and the positions of the roots on cone-beam computed tomography scans; this reduces both the surgical risk and patient trauma. Here we report a case involving a 12-year-old adolescent girl with skeletal Class III malocclusion and midface deficiency that was treated in two phases. In phase 1, rapid maxillary expansion and protraction were performed using 3D-printed mini-plates for anchorage. The mini-plates exhibited better adaptation to the bone contour, and titanium screw implantation was safer because of the customized design. The orthopedic force applied to each mini-plate was approximately 400-500 g, and the plates remained stable during the maxillary protraction process, which exhibited efficacious orthopedic effects and significantly improved the facial profile and esthetics. In phase 2, fixed appliances were used for alignment and leveling of the maxillary and mandibular dentitions. The complete two-phase treatment lasted for 24 months. After 48 months of retention, the treatment outcomes remained stable.

Impact of Using Intra-Operative Ultrasound Guided Breast-Conserving Surgery on Positive Margin and Re-Excision Rates in Breast Cancer Cases with Current SSO/ASTRO Guidelines

  • Thanasitthichai, Somchai;Chaiwerawattana, Arkom;Phadhana-Anake, Oradee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4463-4467
    • /
    • 2016
  • Purpose: To review the impact of using intra-operative ultrasound guided breast conserving surgery with frozen sections on final pathological margin outcome with the current guidelines set forth by the Society of Surgical Oncology (SSO) and the American Society of Surgical Oncology (ASTRO). Materials and Methods: A retrospective review including all cases of intra-operative ultrasound guided breast conserving surgery was performed at the National Cancer Institute Thailand between 2013 and 2016. Patient demographics, tumor variables, intraoperative frozen section and final pathological margin outcomes were collected. Factors for positive or close margins were analyzed. Results: A total of 86 patients aged between 27 and 75 years with intra-operative ultrasound guided breast conserving surgery were included. Three cases (3.5%) of positive margin were detected by intra-operative frozen section and 4 cases (4.7%) by final pathology reports. There were 18 cases (20.9%) with a close margin (<1 mm). Factors affecting this result comprised multi-foci, presence of invasive ductal carcinoma (IDC) combined with ductal carcinoma in situ (DCIS) and invasive lobular carcinoma (ILC). Conclusions: With the current SSO/ASTRO for adequate margin guidelines, using intra-operative ultrasound to locate the boundary for resection with breast conserving surgery provided a high success rate in obtaining final pathology free margin outcomes and minimizing re-operation risks especially when combined with intra-operative frozen section assessment. The chance of finding positive or close margins appears higher in cases of IDC combined with DCIS, ILC and with multi-foci cancers.

CXCL12-CXCR4 Promotes Proliferation and Invasion of Pancreatic Cancer Cells

  • Shen, Bo;Zheng, Ma-Qing;Lu, Jian-Wei;Jiang, Qian;Wang, Tai-Hong;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5403-5408
    • /
    • 2013
  • Objective: CXCL12 exerts a wide variety of chemotactic effects on cells. Evidence indicates that CXCL12, in conjunction with its receptor, CXCR4, promotes invasion and metastasis of tumor cells. Our objective was to explore whether the CXCL12-CXCR4 biological axis might influence biological behavior of pancreatic cancer cells. Methods: Miapaca-2 human pancreatic cancer cells were cultured under three different conditions: normal medium (control), medium + recombinant CXCL12 (CXCL12 group), or medium + CXCR4-inhibitor AMD3100 (AMD3100 group). RT-PCR was applied to detect mRNA expression levels of CXCL12, CXCR4, matrix metalloproteinase 2 (MMP-2), MMP-9, and human urokinase plasminogen activator (uPA). Additionally, cell proliferation and invasion were performed using CCK-8 colorimetry and transwell invasion assays, respectively. Results: CXCL12 was not expressed in Miapaca-2 cells, but CXCR4 was detected, indicating that these cells are capable of receiving signals from CXCL12. Expression of extracellular matrix-degrading enzymes MMP-2, MMP-9, and uPA was upregulated in cells exposed to exogenous CXCL12 (P<0.05). Additionally, both proliferation and invasion of pancreatic cancer cells were enhanced in the presence of exogenous CXCL12, but AMD3100 intervention effectively inhibited these processes (P<0.05). Conclusions: The CXCL12-CXCR4 biological axis plays an important role in promoting proliferation and invasion of pancreatic cancer cells.