• Title/Summary/Keyword: Surgical navigation

Search Result 43, Processing Time 0.017 seconds

Percutaneous Electromagnetic Transthoracic Nodule Localization for Ground Glass Nodules

  • Song, Seung Hwan;Lee, Hyun Soo;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.494-499
    • /
    • 2021
  • Background: A recent increase in the incidental detection of ground glass nodules (GGNs) has created a need for improved diagnostic accuracy in screening for malignancies. However, surgical diagnosis remains challenging, especially via video-assisted thoracoscopic surgery (VATS). Herein, we present the efficacy of a novel electrical navigation system for perioperative percutaneous transthoracic nodule localization. Methods: Eighteen patients with GGNs who underwent electromagnetic navigated percutaneous transthoracic needle localization (ETTNL), followed by 1-stage diagnostic wedge resections via VATS between January and December 2020, were included in the analysis. Data on patient characteristics, nodules, procedures, and pathological diagnoses were collected and retrospectively reviewed. Results: Of the 18 nodules, 17 were successfully localized. Nine nodules were pure GGNs, and the remaining 9 were part-solid GGNs. The median nodule size was 9.0 mm (range, 4.0-20.0 mm); and the median depth from the visceral pleura was 5.2 mm (range, 0.0-14.4 mm). The median procedure time was 10 minutes (range, 7-20 minutes). The final pathologic results showed benign lesions in 3 cases and malignant lesions in 15 cases. Conclusion: Perioperative ETTNL appears to be an effective method for the localization of GGNs, providing guidance for a 1-stage VATS procedure.

Measurement and Algorithm Calculation of Maxillary Positioning Change by Use of an Optoelectronic Tracking System Marker in Orthognathic Surgery (악교정수술에서 광전자 포인트 마커를 이용한 상악골 위치 변화의 계측 및 계산 방법 연구)

  • Park, Jong-Woong;Kim, Soung-Min;Eo, Mi-Young;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.233-240
    • /
    • 2011
  • Purpose: To apply a computer assisted navigation system to orthognathic surgery, a simple and efficient measuring algorithm calculation based on affine transformation was designed. A method of improving accuracy and reducing errors in orthognathic surgery by use of an optical tracking camera was studied. Methods: A total of 5 points on one surgical splint were measured and tracked by the Polaris $Vicra^{(R)}$ (Northern Digital Inc Co., Ontario, Canada) optical tracking system in two cases. The first case was to apply the transformation matrix at pre- and postoperative situations, and the second case was to apply an affine transformation only after the postoperative situation. In each situation, the predictive measuring value was changed to the final measuring value via an affine transformation algorithm and the expected coordinates calculated from the model were compared with those of the patient in the operation room. Results: The mean measuring error was $1.027{\pm}0.587$ using the affine transformation at pre- and postoperative situations and the average value after the postoperative situation was $0.928{\pm}0.549$. The farther a coordinate region was from the reference coordinates which constitutes the transform matrixes, the bigger the measuring error was found which was calculated from an affine transformation algorithm. Conclusion: Most difference errors were brought from mainly measuring process and lack of reproducibility, the affine transformation algorithm formula from postoperative measuring values by using of optic tracking system between those of model surgery and those of patient surgery can be selected as minimizing the difference error. To reduce coordinate calculation errors, minimum transformation matrices must be used and reference points which determine an affine transformation must be close to the area where coordinates are measured and calculated, as well as the reference points need to be scattered.

Safety of Laparoscopic Sentinel Basin Dissection in Patients with Gastric Cancer: an Analysis from the SENORITA Prospective Multicenter Quality Control Trial

  • An, Ji Yeong;Min, Jae Seok;Lee, Young Joon;Jeong, Sang Ho;Hur, Hoon;Han, Sang Uk;Hyung, Woo Jin;Cho, Gyu Seok;Jeong, Gui Ae;Jeong, Oh;Park, Young Kyu;Jung, Mi Ran;Park, Ji Yeon;Kim, Young Woo;Yoon, Hong Man;Eom, Bang Wool;Ryu, Keun Won;Sentinel Node Oriented Tailored Approach (SENORITA) Study Group
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • Purpose: We investigated complications after laparoscopic sentinel basin dissection (SBD) for patients with gastric cancer who were enrolled in a quality control study, prior to the phase III trial of sentinel lymph node navigation surgery (SNNS). Materials and Methods: We analyzed prospective data from a Korean multicenter prerequisite quality control trial of laparoscopic SBD for gastric cancer and assessed procedure-related and surgical complications. All complications were classified according to the Clavien-Dindo Classification (CDC) system and were compared with the results of the previously published SNNS trial. Results: Among the 108 eligible patients who were enrolled in the quality control trial, 8 (7.4%) experienced complications during the early postoperative period. One patient with gastric resection-related duodenal stump leakage recovered after percutaneous drainage (grade IIIa in CDC). The other postoperative complications were mild and patients recovered with supportive care. No complications were directly related to the laparoscopic SBD procedure or tracer usage, and there were no mortalities. The laparoscopic SBD complication rates and patterns that were observed in this study were comparable to those of a previously reported trial. Conclusions: The results of our prospective, multicenter quality control trial demonstrate that laparoscopic SBD is a safe procedure during SNNS for gastric cancer.