• 제목/요약/키워드: Surgical navigation

검색결과 43건 처리시간 0.028초

척추 융합술에서 수술 계획을 재현하기 위한 가상현실 기반 수술 내비게이션 방법 (The Method of Virtual Reality-based Surgical Navigation to Reproduce the Surgical Plan in Spinal Fusion Surgery)

  • 송찬호;손재범;정의성;이호열;박영상;정유수
    • 로봇학회논문지
    • /
    • 제17권1호
    • /
    • pp.8-15
    • /
    • 2022
  • In this paper, we proposed the method of virtual reality-based surgical navigation to reproduce the pre-planned position and angle of the pedicle screw in spinal fusion surgery. The goal of the proposed method is to quantitatively save the surgical plan by applying a virtual guide coordinate system and reproduce it in the surgical process through virtual reality. In the surgical planning step, the insertion position and angle of the pedicle screw are planned and stored based on the virtual guide coordinate system. To implement the virtual reality-based surgical navigation, a vision tracking system is applied to set the patient coordinate system and paired point-based patient-to-image registration is performed. In the surgical navigation step, the surgical plan is reproduced by quantitatively visualizing the pre-planned insertion position and angle of the pedicle screw using a virtual guide coordinate system. We conducted phantom experiment to verify the error between the surgical plan and the surgical navigation, the experimental result showed that target registration error was average 1.47 ± 0.64 mm when using the proposed method. We believe that our method can be used to accurately reproduce a pre-established surgical plan in spinal fusion surgery.

Computer Integrated Surgical Robot System for Spinal Fusion

  • Kim Sungmin;Chung Goo Bong;Oh Se Min;Yi Byung-Ju;Kim Whee Kuk;Park Jong Il;Kim Young Soo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.265-270
    • /
    • 2005
  • A new Computer Integrated Surgical Robot system is composed of a surgical robot, a surgical planning system, and an optical tracking system. The system plays roles of an assisting surgeon and taking the place of surgeons for inserting a pedicle screw in spinal fusion. Compared to pure surgical navigation systems as well as conventional methods for spinal fusion, it is able to achieve better accuracy through compensating for the portending movement of the surgical target area. Furthermore, the robot can position and guide needles, drills, and other surgical instruments or conducts drilling/screwing directly. Preoperatively, the desired entry point, orientation, and depth of surgical tools for pedicle screw insertion are determined by the surgical planning system based on CT/MR images. Intra-operatively, position information on surgical instruments and targeted surgical areas is obtained from the navigation system. Two exemplary experiments employing the developed image-guided surgical robot system are conducted.

Preliminary clinic study on computer assisted mandibular reconstruction: the positive role of surgical navigation technique

  • Huang, Jin-Wei;Shan, Xiao-Feng;Lu, Xu-Guang;Cai, Zhi-Gang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.20.1-20.7
    • /
    • 2015
  • Background: The objectives of the present study were to investigate the reliability and outcomes of computer-assisted techniques in mandibular reconstruction with a fibula flap and verify whether the surgical navigation system was feasible in mandible reconstructive surgery. Methods: Eight cases were enrolled in the computer assisted surgery (CAS) group and 14 cases in the traditional group. The shaping and fixation of the fibula grafts were guided by computer assisted techniques, which could be monitored with the BrainLAB surgical navigation system. The variation of mandible configuration was evaluated by CT measurement in the Mimics software, including the variation of length, width, height and gonial angle of the mandible. The 3D facial soft tissue alteration was also analyzed in 3D chromatogram by Geomagic software. Results: All 22 fibula flaps survived. The mandibular configurations and facial contours had a better clinic result in the CAS group. The length, width, height and gonial angle of the reconstructive mandible were more similar to the original one. The Wilcoxon rank sum test analysis suggested significant differences in the measurements. The chromatographic analysis also visually showed superiority over the traditional group. Conclusions: The computer assisted surgical navigation method used in mandibular reconstruction is feasible and precise for clinical application. The contour of the reconstructed mandible and facial symmetry are improved with computer techniques.

광추적기와 내부 비전센서를 이용한 수술도구의 3차원 자세 및 위치 추적 시스템 (3D Orientation and Position Tracking System of Surgical Instrument with Optical Tracker and Internal Vision Sensor)

  • 조영진;오현민;김민영
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.579-584
    • /
    • 2016
  • When surgical instruments are tracked in an image-guided surgical navigation system, a stereo vision system with high accuracy is generally used, which is called optical tracker. However, this optical tracker has the disadvantage that a line-of-sight between the tracker and surgical instrument must be maintained. Therefore, to complement the disadvantage of optical tracking systems, an internal vision sensor is attached to a surgical instrument in this paper. Monitoring the target marker pattern attached on patient with this vision sensor, this surgical instrument is possible to be tracked even when the line-of-sight of the optical tracker is occluded. To verify the system's effectiveness, a series of basic experiments is carried out. Lastly, an integration experiment is conducted. The experimental results show that rotational error is bounded to max $1.32^{\circ}$ and mean $0.35^{\circ}$, and translation error is in max 1.72mm and mean 0.58mm. Finally, it is confirmed that the proposed tool tracking method using an internal vision sensor is useful and effective to overcome the occlusion problem of the optical tracker.

Constrained High Accuracy Stereo Reconstruction Method for Surgical Instruments Positioning

  • Wang, Chenhao;Shen, Yi;Zhang, Wenbin;Liu, Yuncai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권10호
    • /
    • pp.2679-2691
    • /
    • 2012
  • In this paper, a high accuracy stereo reconstruction method for surgery instruments positioning is proposed. Usually, the problem of surgical instruments reconstruction is considered as a basic task in computer vision to estimate the 3-D position of each marker on a surgery instrument from three pairs of image points. However, the existing methods considered the 3-D reconstruction of the points separately thus ignore the structure information. Meanwhile, the errors from light variation, imaging noise and quantization still affect the reconstruction accuracy. This paper proposes a method which takes the structure information of surgical instruments as constraints, and reconstructs the whole markers on one surgical instrument together. Firstly, we calibrate the instruments before navigation to get the structure parameters. The structure parameters consist of markers' number, distances between each markers and a linearity sign of each instrument. Then, the structure constraints are added to stereo reconstruction. Finally, weighted filter is used to reduce the jitter. Experiments conducted on surgery navigation system showed that our method not only improve accuracy effectively but also reduce the jitter of surgical instrument greatly.

임상가를 위한 특집 1 - 컴퓨터 기반 악골 종양의 절제 및 재건술 (Computer-aided Maxillofacial ablation and reconstruction Surgery)

  • 문성용;임성훈
    • 대한치과의사협회지
    • /
    • 제52권10호
    • /
    • pp.596-601
    • /
    • 2014
  • Computer-aided surgery is popular and useful in the field of oral and maxillofacial surgery, because of the possibility of simulation with a high accuracy. In all aspects of surgery, proper planning facilitates more predictable operative results, however before the use of virtual planning, much of this relied on 2-dimensional (2-D) imaging for treatment planning on a 3-dimensional (3-D) object and surgical trial and error. With real-time instrument positioning and clear anatomic identification, a computer-assisted navigation system (CANS) is exceptionally helpful in maxillofacial surgery. These techniques enable performing precise bony ablation and reconstruction, and also decrease surgical time and donor site defect.

Computer-Assisted Modified Mid-Sacrectomy for En Bloc Resection of Chordoma and Preservation of Bladder Function

  • Han, In-Ho;Seo, Young-Jun;Cho, Won-Ho;Choi, Byung-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권6호
    • /
    • pp.523-527
    • /
    • 2011
  • A 67-year-old woman presented for evaluation of severe coccygeal pain. The computed tomography scans and magnetic resonance imaging showed an asymmetric midline sacral tumor invading the right lower portion of S2. To preserve both S2 nerve roots and to obtain negative surgical margins, a modified mid-sacrectomy with an aid of a computed navigation system was performed. The sacral tumor was excised en bloc with negative tumor margins. Both S2 nerve roots were preserved and additional reconstruction was not necessary because of minimal resection of the sacroiliac joint. We report a case of a sacral chordoma which was excised en bloc with adequate surgical margins by a computer-assisted modified mid-sacrectomy. The computed navigation system may be a useful tool for tumor targeting and safe osteotomies in sacral tumor surgery via the posterior only approach.

오픈소스 기반 수술항법장치의 하지 골절수술 응용검토 (Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb)

  • 정상현;박재영;박철우;오창욱;박일형
    • 대한기계학회논문집A
    • /
    • 제38권5호
    • /
    • pp.497-503
    • /
    • 2014
  • 골절 치료에서 최소 침습 수술 방법은 그 효용성이 입증 되었지만, 의료진이 골편을 직접 볼 수 없기 때문에 방사선 투시영상장치(C-armed fluoroscopy)에 의존하여 수술을 진행하게 된다. 최소침습 수술은 환자에게는 감염이 적고 회복이 빠르다는 장점이 있지만 의료진에게는 과도한 방사선 피폭과 부정확한 골절정복 가능성이 높아지는 문제점이 발생할 수 있다. 본 연구에서는 이와 같은 문제를 해결하기 위해 수술 항법장치와 수술 지원로봇을 활용하는 방법을 제안한다. 골편의 3D CT 모델을 실제 골편과 특징점을 이용해서 정합하는 오픈 소스 기반으로 구성된 수술 항법 장치와 2D 투시 영상에서 골편간의 회전 변위를 정상측 투시 영상과 비교하여 확인 할 수 있는 방법을 제안하였고, 모델 뼈를 이용한 실험으로 제안한 방법의 임상적 타당성을 확인하였다. 그 결과 3D CT-기반 수술 항법 장치의 모델 뼈와 영상정합 정확도는 약 2mm 로 정형외과 수술에서 요구되는 사양을 만족했으며, 2D 투시 영상에서는 ${\pm}15^{\circ}$범위의 골편간의 회전에서 $2.5^{\circ}$이하의 변별력을 나타내었다.