• 제목/요약/키워드: Surgical measurement.

검색결과 200건 처리시간 0.023초

Measurement of Orbit using Standardized Processing of CT Scan

  • Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권1호
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose Surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these surgeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable reationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. Method Author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Results The method was allowed to evaluate inter-dacryon distance, inter-centroid distance, movement of the medial orbital wall, movement of the lateral orbital wall, alteration of thickness of the lateral periorbital fat as indicator of movement of the orbital wall and orbit in the patient with congenital periorbital anomaly and postoperative periorbital surgery. The goal of surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these sugeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable relationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. In this report, author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Conclusion The method suggested is objective and accurate method in measurement of the orbital contents. It takes time and is not easy to do, however, this kind of measurement for fine structures will be more easily available in near future.

Methodological validation of measuring Hanwoo hair cortisol concentration using bead beater and surgical scissors

  • Nejad, Jalil Ghassemi;Ataallahi, Mohammad;Park, Kyu-Hyun
    • Journal of Animal Science and Technology
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2019
  • Different methodologies in hair cortisol extraction may alter the final output. Thus finding the standard methodology according to a laboratory facilities is pivotal. This study was carried out to validate the feasibility of two methods of grinding hair for cortisol extraction in Korean native (Hanwoo) cattle. Hair from nine cattle including mature cows, heifers, and calves were assigned to one of the following methods for grinding hair; 1) using bead beater (BB) and 2) using surgical scissors (SS). Hair samples (> 1 g) were harvested from forehead of each individual twice (first and second measurement) to validate the results. To improve the accuracy of the obtained data, each sample was duplicated into two wells during enzyme immunoassay (EIA) analysis. Overall comparison of hair cortisol concentration (HCC) showed that the data within the range (out of the range) of standards provided by the EIA kit were 88.9% (11.1%) and 66.7% (33.3%) for BB compared with SS, respectively. In the first measurement, application of BB was tended to show higher (p = 0.056) amount of HCC compared with SS. In the second measurement application of BB showed higher (p = 0.0028) amount of HCC compared with SS. Among the cattle, calves showed higher HCC using BB compared with SS (p < 0.05). Application of BB in hair grinding methodology for Hanwoo cattle may improve cortisol extraction in comparison to application of SS method, with more consistency. Thus, it would be the preferable method to use.

치은 염증 상태에 따른 치주낭 측정 깊이와 방사선학적 측정 깊이, 외과적 측정 깊이의 비교 연구 (A COMPARATIVE STUDY OF THE PROBING ATTACHMENT LEVEL, RADIOGRAPHIC AND SURGICAL MEASUREMENT ACCORDING TO GINGIVAL INFLAMMATORY CONDITION)

  • 백동훈;채중규;조규성;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제24권2호
    • /
    • pp.261-270
    • /
    • 1994
  • The purpose of this study was to evaluate relationship of probing attachment levels, radiographic measurements and surgical measurements according to gingival inflammatory condition. Patients with incipient to moderate periodontitis were selected. Upper and lower premolar and molar teeth excluding third molars were measured. At first visit, gingival index and bleeding on probing were taken, and subjects were grouped into 4 categories as follows : Experimental group I : gingival index 1 and no bleeding on probing. Experimental group II : gingival index 2 and no bleeding on probing absent. Experimental group III : gingival index 1 and bleeding on probing present. Experimental group IV : gingival index 2 and bleeding on probing present. Probing attachment levels were measured with manual probe on mesial and distal surfaces from cementoenamel junctions to terminal ends of probe. Radiographic measurements were made to assess bone loss by measuring the distance from cementoenamel junction to the alveolar crest. After thorough scating, a flap was raised exposing the alveolar bone and surgical measurements were made from cementoenamel junction to alveolar bone. The results were as follows: 1. Differences between probing attachment level and radiographic measurements showed $1.01{\pm}0.73mm$ for experimental group I, $0.98{\pm}0.48mm$ for experimental group II, $0.59{\pm}0.66mm$ for experimental group III, $0.98{\pm}0.38mm$ for experimental group IV and with no significant difference between groups. 2. Differences between probing attachment level and surgical measurements showed $1.36{\pm}0.80mm$ for experimental group I, $1.47{\pm}0.54mm$ for experimental group II, $1.06{\pm}0.39mm$ for experimental group III, $1.41{\pm}0.40mm$ for experimental group IV and with no significant difference between groups. 3. Differences between surgical and radiographic measurements showed $0.36{\pm}0.48mm$ for experimental group I, $0.51{\pm}0.54mm$ for experimental group II, $0.57{\pm}0.72mm$ for experimental group III, $0.41{\pm}0.49mm$ for experimental group IV and with significant difference between experimental group I and experimental group II, III, IV(P<0.05).

  • PDF

환자의 수술후 경과시간에 따른 동통정도의 변화에 관한 연구 (A Survey on Changes of Postoperative Pain of Surgical Patients according to Time Variation)

  • 이은옥;김수진;이경숙
    • 대한간호학회지
    • /
    • 제14권1호
    • /
    • pp.60-68
    • /
    • 1984
  • The main purpose of this study is to observe patterns of pain of surgical patients following surgery The postoperative pain was checked with the interval of every 2 hours from 6 hours to 80 hours after surgery. Graphic rating scale from unidimensional concept of pain and sensory intensity scale and unpleasantness scale from two dimensional concept of pain were used for pain measurement. Thirty two patients were participated in this study in which 22 were undergone upper abdominal surgery, 7 thyroid or neck surgery and 3 other surgeries. The findings obtained from this study were as follows: 1) In all cases of using 3 different pain measurement tools, postoperative pain was markedly decreased since 36 hours after surgery. In case of patient's less cooperation, either sensory intensity scale or graphic rating scale may be chosen for the measurement of pain. 2) Pain amounts measured by sensory intensity scale were highly correlated with those measured by unpleasantness scale in all situations except several situations having few cases included. Unpleasantness scale may be separately used for themeasurement of affective response due to pain. 3) Almost 90% of total amount of analgesics used for relief of pain were used within 36 hours after surgery. 4) Mean frequency of analgesics used by every patient during 80 hours following surgery was 0.84.

  • PDF

선천성 대동맥 협착증의 술전 및 술후 단기간의 수축말기 좌심실 내벽 스트레스의 변화 (Alterations in Left ventricular End-systolic Wall Stress During Short-term Follow-up After Correction of Isolated Congenital Aortic Stenosis)

  • 김시호
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.777-784
    • /
    • 2000
  • Congenital aortic stenosis in children is characterized by "excessive" left ventricular hypertrophy with reduced left ventricular systolic wall stress that allows for supernormal ejection performance. We hypothesized that left ventricular wall stress was decreased immediately after surgical correction of pure congenital aortic stenosis. Also measuring postoperative left ventricular wall stress was a useful noninvasive measurement that allowed direct assessment for oxygen consumption of myocardium than measuring the peak systolic pressure gradient between ascending aorta and left ventricle for the assessment of surgical results. Material and Method: Between September 1993 and August 1999, 8 patients with isolated congenital aortic stenosis who underwent surgical correction at Yonsei cardiovascular center were evaluated. There were 6 male and 2 female patients ranging in age from 2 to 11 years(mean age, 10 years). Combined Hemodynamic-Ultrasonic method was used for studying left ventricular wall stress. We compared the wall stress peak systolic pressure gradient and ejection fraction preoperatively and postoperatively. Result: After surgical correction peak aortic gradient fell from 58.4${\pm}$17.6, to 23.7${\pm}$17.7 mmHg(p=0.018) and left ventricular ejection fraction decreased but it is not statistically significant. In the consideration of some factors that influence left ventricular end-systolic wall stress excluding one patient who underwent reoperation for restenosis of left ventricular outflow tract left ventricular end-systolic pressure and left ventricular end-systolic dimension were fell from 170.6${\pm}$24.3 to 143.7${\pm}$27.1 mmHg and from 1.78${\pm}$0.4 to 1.76${\pm}$0.4 cm respectively and left ventricular posterior wall thickness was increased from 1.10${\pm}$0.2, to 1.27${\pm}$0.3cm but it was not statistically singificant whereas left ventricular end-systolic wall stress fell from 79.2${\pm}$24.9 to 57.1${\pm}$27.6 kdynes/cm2(p=0.018) in 7 patients. For one patient who underwent reoperation peak aortic gradient fell from 83.0 to 59.7 mmHg whereas left ventricular end-systolic wall stress increased from 67.2 to 97.0 kdynes/cm2 The intervals did not change significnatly. Conclusion ; We believe that probably some factors that are related to left ventricular geometry influenced the decreased left ventricular wall stress immediately after surgical correction of isolated congenital aortic stenosis. Left ventricular wall stress is a noninvasive measurement and can allow for more direct assesment than measuring peak aortic gradient particularly in consideration of the stress and oxygen consumption of the myocardium therefore we can conclude it is a useful measurement for postoperative assessment of congenital aortic stenosis.

  • PDF

하악골 골절 환자에서의 C-Reactive Protein의 변화 (THE CHANGES OF C-REACTIVE PROTEIN IN THE PATIENTS ASSOCIATED WITH MANDIBULAR FRACTURE)

  • 곽종민;김철환;김경욱
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.35-41
    • /
    • 2006
  • It is well known that concentration of C-reactive protein(CRP) in the serum increase as nonspecific reaction of the various tissue injury. The CRP, synthesized in the hepatocyte, is one of 'acute phase proteins' in the serum. The main signal patterns of this protein are regulated by synthesis of interleukin-I secreted from macrophage in the area of tissue injury. Many studies were performed for quantitative analysis for CRP according to various surgical operation, but the study for fracture patients associated with trauma, especially in mandible, are rare. The mandible fracture have intrinsic danger for infection in oral bacteria associated with open wound in oral cavity, and, are difficult for detection of tissue reaction between surgical swelling and infection by facial swelling. In this study, quantitative analysis for CRP associated tissue injury in mandibular fracture and surgical intervention was done, the results were as follows: 1. After initial mandibular trauma, the value of serum CRP diminished sequentially, most high value was presented in post-traumatic 2 days. 2. The CRP was diminished significantly 2 days after surgical intervention, and maintained normal value in 5 days after surgery. 3. The change of CRP are higher value in surgical intervention than initial trauma, it suggested that tissue injury from surgery was severe than trauma. 4. The high value of CRP was obtained in mandibular fracture combined soft tissue injury than no associated soft tissue injury. 5. In measurement of CRP according to surgical approach, highest serum value in patients of combined intra-oral and extra-oral approach was showed, and intra-oral approach, extra-oral approach, in sequential orders. 6. The CRP value are more higher in patient of 2 fracture site than only one fracture site. From the results obtained in this study, CRP has showed different values in mandibular fracture associated with severity of tissue injury and surgical intervention, and quantitative analysis of CRP value in serum can be applied to the clinical management of mandibular fracture.

Storage of laboratory animal blood samples causes hemorheological alterations : Inter-species differences and the effects of duration and temperature

  • Nemeth, Norbert;Baskurt, Oguz K.;Meiselman, Herbert J.;Kiss, Ferenc;Uyuklu, Mehmet;Hever, Timea;Sajtos, Erika;Kenyeres, Peter;Toth, Kalman;Furka, Istvan;Miko, Iren
    • Korea-Australia Rheology Journal
    • /
    • 제21권2호
    • /
    • pp.127-133
    • /
    • 2009
  • Hemorheological results may be influenced by the time between blood sampling and measurement, and storage conditions (e.g., temperature, time) during sample delivery between laboratories may further affect the resulting data. This study examined possible hemorheological alterations subsequent to storage of rat and dog blood at room temperature ($22^{\circ}C$) or with cooling ($4{\sim}10^{\circ}C$) for 2, 4, 6, 24, 48 and 72 hours. Measured hemorheological parameters included hematological indices, RBC aggregation and RBC deformability. Our results indicate that marked changes of RBC deformability and of RBC aggregation in whole blood can occur during storage, especially for samples stored at room temperature. The patterns of deformability and aggregation changes at room temperature are complex and species specific, whereas those for storage at the lower temperature range are much less complicated. For room temperature storage, it thus seems logical to suggest measuring rat and dog cell deformability within 6 hours; aggregation should be measured immediately for rat blood or within 6 hours for dog blood. Storage at lower temperatures allows measuring EI up to 72 hours after sampling, while aggregation must be measured immediately, or if willing to accept a constant decrease, over 24~72 hours.

CT Scanogram과 고식적방법에 의한 장골계측촬영의 비교분석 (The Comparative Analysis on the Radiography of Long Bone Measurement by CT Scanogram and Conventional Method)

  • 김승국;전재두
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.29-33
    • /
    • 2001
  • The accurate measurement for a long bone have taken an important part in orthopedics surgical diseases when the length of extremities is different each other. However, it is true that various kinds of methods to search for the accurate measurement on used in medical centers. In this study, we measured the real length of long bone for CT Scanogram and F.F.D by 100cm and 200cm in the angle of inclination $0^{\circ},\;3^{\circ}$ and $7^{\circ}$. This method will be useful to diagnose and treat patients more accurately.

  • PDF

Preliminary clinic study on computer assisted mandibular reconstruction: the positive role of surgical navigation technique

  • Huang, Jin-Wei;Shan, Xiao-Feng;Lu, Xu-Guang;Cai, Zhi-Gang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.20.1-20.7
    • /
    • 2015
  • Background: The objectives of the present study were to investigate the reliability and outcomes of computer-assisted techniques in mandibular reconstruction with a fibula flap and verify whether the surgical navigation system was feasible in mandible reconstructive surgery. Methods: Eight cases were enrolled in the computer assisted surgery (CAS) group and 14 cases in the traditional group. The shaping and fixation of the fibula grafts were guided by computer assisted techniques, which could be monitored with the BrainLAB surgical navigation system. The variation of mandible configuration was evaluated by CT measurement in the Mimics software, including the variation of length, width, height and gonial angle of the mandible. The 3D facial soft tissue alteration was also analyzed in 3D chromatogram by Geomagic software. Results: All 22 fibula flaps survived. The mandibular configurations and facial contours had a better clinic result in the CAS group. The length, width, height and gonial angle of the reconstructive mandible were more similar to the original one. The Wilcoxon rank sum test analysis suggested significant differences in the measurements. The chromatographic analysis also visually showed superiority over the traditional group. Conclusions: The computer assisted surgical navigation method used in mandibular reconstruction is feasible and precise for clinical application. The contour of the reconstructed mandible and facial symmetry are improved with computer techniques.