• Title/Summary/Keyword: Surgical handpiece

Search Result 13, Processing Time 0.034 seconds

Development of Battery Type Powered Handpiece Drive System for Surgical Operation (Battery type 외과수술용 핸드피스 구동 드라이브 시스템)

  • Ha, Jung-Jun;Yoon, Yong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

Development of Air-powered Handpiece for Surgical Operation (외과 수술용 Air-Powered Handpiece 개발)

  • 윤길상;이영훈;허영무;서태일;최길운
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.188-193
    • /
    • 2004
  • The purpose of this paper is concerned with a development of an air-powered handpiece for surgical operation. The handpiece is the tool of surgical instruments and it can be used to interchange multiple attachments for drilling, pinning, sawing, driving screws and reaming. Most of domestic medical instruments bring in overseas and the air-powered handpiece imported from foreign countries at 100% too. Therefore we develop new air powered handpiece. we research in 2D and 3D modeling, design of air line, analyze structure. The air-powered handpiece composes of body, power supply air-line, elements for mechanical power transmission, attachment, and surgical tools. The handpiece is developed by several processes that 3D design, machining, heat treatment and coating. The developed handpiece is experimented to confirm check the efficiency.

Drive System of Battery Type Surgical Handpiece (배터리형 외과수술용 핸드피스 구동 시스템)

  • Kong, Tae-Woong;Park, Sang-Hoon;Yu, Jae-Sung;Lee, Byoung-Kuk;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.369-373
    • /
    • 2007
  • Battery type surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type.

  • PDF

Extensive Bilateral Subcutaneous Emphysema after Dental Treatment: Two Case Reports

  • Gyu-Beom Kwon;Chul-Hwan Kim ;Hae-Seo Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.80-86
    • /
    • 2023
  • We report two rare cases of extensive bilateral subcutaneous emphysema that occurred during ordinary dental procedures. An air-driven high-speed handpiece, routinely used in dental procedures may cause subcutaneous emphysema when high pressure air is introduced into the loose connective tissues below the dermal layer. The first case occurred with surgical extraction of the lower third molar. The air introduced into the fascial spaces near the surgical field spread to the contralateral spaces, as well as the neck and chest areas. The second case also showed extensive bilateral subcutaneous emphysema caused by the introduction of compressed air from the handpiece during crown preparation without any invasive procedure. Cases where the emphysema extends beyond the treatment site to involve the contralateral cervicofacial areas have been rarely reported. Predicting the occurrence of subcutaneous emphysema is difficult, so it is important to exercise caution during routine dental treatment. If significant bilateral cervicofacial swelling is suspected to be due to subcutaneous emphysema, prompt diagnosis with securing the patient's airway will be necessary.

Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency (초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구)

  • Kim, Hong Rae;Kim, Sung Chun;Kim, Kwang Gi;Kim, Young-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

Analyses of Influence of Frictional Heat on the Contact Stress of High-speed Micro-gears

  • Kim, Cheol;Kim, Hyeong-Seok
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.244-248
    • /
    • 2015
  • When a small gear rotates at a very high speed over 40,000 rpm, frictional heat is generated on the gear surfaces. Thermal deformations and stresses arising from frictional heat may lower the efficiency and fatigue life of the high-speed gear. Especially, such frictional heat has much stronger effects on the performance of millimeter-sized high-speed gears used for surgical and dental hand-pieces, due to a small surface area. An analytical equation was derived to calculate frictional temperature on a mating gear surface and conduction heat transfer analysis was performed. Thermal deformation and contact stresses were then calculated using FEM for gears used for medical hand-pieces. The contact stresses of the meshed gear and pinion increase by 19.4% and 16.4%, respectively, when the frictional thermal deformations are considered.

Battery Type Surgical Handpiece Using Brushless DC Motor Drive (배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브)

  • Yu, Jae-Sung;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.128-130
    • /
    • 2007
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진 수술 기법인 인공관절 대체 수술 시 뼈(Bone)절단, 다듬질 구멍 등, 초 섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF

Percutaneous self-injury to the femoral region caused by bur breakage during surgical extraction of a patient's impacted third molar

  • Yu, Tae Hoon;Lee, Jun;Kim, Bong Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.281-283
    • /
    • 2015
  • Extraction of an impacted third molar is one of the most frequently performed techniques in oral and maxillofacial surgery. Surgeons can suffer numerous external injuries while extracting a tooth, with percutaneous injuries to the hand being the most commonly reported. In this article, we present a case involving a percutaneous injury of the surgeon's femoral region caused by breakage of the fissure bur connected to the handpiece during extraction of the third molar. We also propose precautions to prevent such injuries and steps to be undertaken when they occur.

Successful Surgical Treatments of Scleral Rupture with Hyphema in a Young Cat (어린 고양이에서 발생한 안구내출혈을 동반한 공막 파열의 수술적 치료)

  • Park, Youngwoo;Jung, Yechan;Lim, Jae Hyun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.127-129
    • /
    • 2015
  • A 3-month-old, female Persian cat was presented with sclera mass. The mass was detected after cat's squeals during the playing with a dog before 2 days. On ophthalmic examination, a $2{\times}5mm$ dark purple colored raised mass was observed 1 mm behind the limbus in the right eye. Anterior chamber was filled with blood and epithelial defect was detected at 2 o'clock in the right central cornea. After general anesthesia, resection of the protruded iris was performed with iris scissors and bipolar cautery. Ruptured sclera and conjunctiva were closed with simple interrupted and simple continuous suture, respectively. Also, irrigation and aspiration (I/A) of the anterior chamber was performed to remove blood clot with bimanual I/A handpiece in the right eye. Four months after the surgery, the right eye was recovered completely and menace response was positive in spite of the retinal lesions.

Development of Surgical Two-wavelegth Nd:YAG Laser (수술용 2파장 펄스형 Nd:YAG 레이저 개발)

  • 윤길원;김홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF