• Title/Summary/Keyword: Surgical Staplers

Search Result 17, Processing Time 0.025 seconds

Anastomotic Complications after Esophageal Reconstruction (식도재건술후 문합부 합병증)

  • Lee, Chul-Burm;Hahm, Shee-Young;Kim, Hyuk;Jung, Won-Sang;Kim, Young-Hak;Kang, Jung-Ho;Baik, Hong-Kyu
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.1
    • /
    • pp.62-71
    • /
    • 2000
  • Background: For the purpose of reducing operating time and rate of anastomotic leakage, we have performed esophagovisceral anastomosis with an EEA stapler using the largest size possible. If any difficulty in the approach of the EEA stapler was encountered one-layer interrupted hand-sewn anastomosis. Because the rate of postoperative benign anastomotic stricture was higher than expected, a retrospective study was done on all patients who underwent esophageal reconstruction. Material and Method: Over a period of 3 years from January 1996 to December 1998, we performed esophageal reconstructions on 30 patients. Patients were divided into two groups ; EEA stapler group(Group Ⅰ) comprised of 21 patients and hand-sewn group(Group Ⅱ) comprised of 9 patients.Result:The hospital mortality was 6.67 %(2/30) and the anastomotic leakage rate was 3.33 %(1/30). Among the discharged patients, the rate of recurrent anastomotic tumor was 3.57 %(1/28) and the rate of benign anastomotic stricture stricture rate was 35 %(7/20) in Group Ⅰ and 12.5 %(1/8) in Group Ⅱ, which was not significant. Conclusion: Although nontumor benign stricture was significantly higher in Group Ⅱ than in Group Ⅰ(p=0.0492), the incidence of anastomotic complications did not differ between the two groups. The one-layer interrupted hand-sewn esophagovisceral anastomosis by maintaining a wide lumen and close approximation of mucosa to mucosal layers with evenly spaced sutures could be one of the preferred surgical method to reduce benign anastomotic strictures.

  • PDF

Factors Affecting the Number of Stapler Cartridges in Complete Video-Assisted Thoracoscopic Surgery Lobectomy for Non-small Cell Lung Cancer

  • Yang, Young Ho;Lee, Seokkee;Lee, Chang Young;Kim, Dae Joon;Lee, Jin Gu;Chung, Kyung-Young
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.53-57
    • /
    • 2020
  • Background: Video-assisted thoracoscopic surgery (VATS) lobectomy has become the major surgical option for the treatment of non-small cell lung cancer (NSCLC). Endoscopic instruments such as stapler cartridges are essential for VATS procedures. In this study, we investigated the factors that affect the number of stapler cartridges used in VATS lobectomy. Methods: A retrospective analysis was conducted of patients who underwent complete VATS lobectomy for NSCLC from January 2013 to December 2015. Results: In total, 596 patients underwent complete VATS lobectomy. The average number of stapler cartridges used for VATS lobectomy was 5.3±1.9. The number of stapler cartridges used for VATS lobectomy was higher in men (5.5±1.9 vs. 5.0±18, p=0.006), those aged older than 70 years (5.5±2.1 vs. 5.1±1.7, p=0.038), those who underwent upper or middle lobectomy procedures (5.7±1.9 vs. 4.1±1.2, p<0.001), those with a higher fissure sum average (p<0.001), and those in whom surgery was performed by a surgeon with a preference for staplers (5.6±2.0 vs. 4.9±1.6, p<0.001). Conclusion: The number of stapler cartridges required to perform VATS lobectomy in NSCLC patients appears to be influenced by sex, age, the location of the tumor, the degree of fissure development, and the surgeon's preference.

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF

The Early Experience with a Totally Laparoscopic Distal Gastrectomy (전(全)복강경하 원위부 위절제술의 초기 경험)

  • Kim Jin Jo;Song Gyo Young;Chin Hyung Min;Kim Wook;Jeon Hae Myoung;Park Cho Hyun;Park Seung Man;Lim Keun Woo;Park Woo Bae;Kim Seung Nam
    • Journal of Gastric Cancer
    • /
    • v.5 no.1
    • /
    • pp.16-22
    • /
    • 2005
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been increasing lately. Although minimally invasive surgery is more beneficial, no reported case of a totally laparoscopic distal gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experiences, to determine the feasibility of a totally laparoscopic distal gastrectomy using an intracorporeal gastroduodenostomy in treating early gastric carcinoma. Materials and Methods: We investigated surgical results and clinicopatholgic characteristics of eight(8) patients with an early gastric carcinoma who underwent a totally laparoscopic distal gastrectomy at the Department of Surgery, Our Lady of Mercy Hospital, The Catholic University of Korea, between June 2004 and September 2004. The intracorporeal gastroduodenostomy was performed with a delta-shaped ananstomosis by using only laparoscopic linear staplers (Endocutter 45mm; Ethicon Endosurgery, OH, USA). Results: The operative time was $369.4\pm62.5$ minutes (range $275\∼465$ minutes), and the anastomotic time was 45.1\pm14.4$ minutes (range $32\∼70$ minutes). The anastomotic time was shortened as surgical experience was gained. The number of laparoscopic linear staplers for an operation was $7.1\pm0.6$. The number of lymph nodes harvested was $31.9\pm13.1$. There was 1 case of transfusion and no case of conversion to an open procedure. The time to the first flatus was 2.8$\pm$0.5 days, and the time to the first food intake was $4.1\pm0.8$ days. There were no early postoperative complications, and the postoperative hospital stay was $10.0\pm3.9$ days. Conclusion: A totally laparoscopic distal gastrectomy using an intracorporeal gastroduodenostomy with a delta-shaped anastomosis is technically feasible and can maximize the benefit of laparoscopic surgery for early gastric cancer.

  • PDF

Comparison of End-to-side and End-to-end Anastomosis in Circular Stapled Gastroduodenostomy (원형 봉합기를 이용한 위십이지장연결술 시 단측연결과 단단연결의 비교)

  • Seo, Min-Woo;Kim, Yong-Jin;Song, Dan;Kang, Gil-Ho;Cho, Gyu-Seok;Lee, Moon-Soo;Hur, Kyung-Yul;Kim, Jae-Joon
    • Journal of Gastric Cancer
    • /
    • v.9 no.2
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: The use of automatic circular staplers for gastroduodenostomy after distal gastrectomy is now widely accepted. We compared the clinical outcomes of two different methods. Materials and Methods: Between March 2005 and February 2008, 134 patients with gastric cancer underwent distal gastrectomies. Seventy-six consecutive patients received end-to-side gastroduodenostomies (ES) between March 2005 and September 2006. The remaining 58 consecutive patients received end-to-end gastroduodenostomies (EE) between November 2006 and February 2008. We analyzed the surgical outcomes between the two groups (ES versus EE) on the basis of prospectively collected data. Results: Among the clinical factors, there were no differences between the two groups. The overall complication rates were 19.7% in the ES group and 13.8% in the EE group (P=0.489). With respect to anastomosis-related complications, 2 cases had bleeding and 2 cases had stenoses in the ES group, while 2 cases in the EE group had bleeding. Re-operation was needed in the case of intraluminal bleeding in the ES group. There were no mortalities in our study. Conclusion: The two methods for gastroduodenostomy were safe and technically feasible. Although there was no statistical difference in the overall complications, including anastomosis-related complications, we demonstrated better outcomes with respect to anastomotic stenosis in the EE group.

  • PDF

Experimental and Clinical Study of Staple-Line Reinforcement Using Expanded Polytetrafluoroethylene in Thoracoscopic Bullectomy for Spontaneous Pneumothorax (자연 기흉 환자에서 봉합선 보강이 흉강경 폐부분 절제술에 미치는 영향: 동물실험 및 임상연구)

  • 문석환;심성보;왕영필;윤정섭;조건현;박재길;박만실;최시영;곽문섭
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.904-910
    • /
    • 2003
  • Thoracoscopic bullectomy (VATS-B) is now the preferred treatment for spontaneous pneumothorax despite of higher recurrence rate than open thoracotomy. Several methods have been used to prevent this problem. The effectiveness of staple line reinforcement (SLR) in VATA-B using endostaplers was assessed by clinical and experimental study. Meterial and Method: In experimental study, canine lungs were harvested immediately (group I N=5) and 48 hours (group II N=5) after stapling. The pressures at which initial air leaks occurred were measured. In clinical study from February 1997 to March 1999, 106 procedures in 104 patients undergoing VATS-B for spontaneous pneumothorax were classified into two groups according to the presence of SLR and were compared. Result: The average pressure of the initial air leakage was significantly higher in SLR than that of staples alone (18$\pm$1.6 vs 48$\pm$3 mm Hg in group I; 23.8$\pm$1.9 vs 54$\pm$4.6 mm Hg in group II, p<0.001). In the clinical data, there were significant differences seen in the duration of drainage, the total length of endostaplers used, and the duration of the postoperative hospital stay between patients with staple alone and patients with SLR (4.4$\pm$1.4 vs 3.1$\pm$1.1 days in duration of drainage, 92.3$\pm$28.1 vs 71.1$\pm$30.6 mm in total length of endostaplers used, 5.9$\pm$1.9 vs 4.6$\pm$1.7 days in postoperative hospital stays, p<0.001). Conclusion: SLR was effective for preventing prolonged air leakage and responsible for shorter hospital stays after VATS-B for the treatment of spontaneous pneumothorax.

Pledget as a Useful Substitute for a Knot in Intracorporeal Continuous Gastrointestinal Suturing (복강 내 위장관 연속 손바느질에서 매듭 대용으로서의 Pledget의 유용성)

  • Kim, Jin-Jo;Song, Kyo-Young;Kim, Sung-Keun;Jun, Kyong-Hwa;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.146-151
    • /
    • 2007
  • Purpose: Pledget is a PTFE felt that is usually used for suture reinforcement in cardiovascular surgery. In order to minimize the difficulty in intracorporeal continuous gastrointestinal suturing by reducing the number of tied knots, we have used pledget as substitute for a knot (pledget suturing). Materials and Methods: Thirty-two consecutive patients who underwent totally laparoscopic uncut Roux-en-Y gastrojejunostomy after distal gastrectomy in our institution were enrolled in this study, and the patients were divided into three groups according to the method of intracorporeal anastomosis. Basically, intracorporeal anastomosis was performed by several firings of linear staplers; however, the entry holes for the stapler at the jejunojejunostomy and the gastrojejunostomy were closed by pledget suturing in group A (8 patients), the entry hole for the stapler at jejunojejunostomy was closed by conventional suturing in group B (8 patients), and all of the entry holes for the stapler were closed by stapling in group C (16 patients). The surgical outcomes of each group were compared to each other. Results: The anastomotic time in group A was not longer than in group B, although there were more sutures used in group A, but it was longer than in group C. The number of stapler cartridges used in group A was the smallest among the three groups. In group B, there were two cases of a break of suture material during anastomosis, there were no such cases in group A. There was no complication related to anastomosis in all of the groups. Conclusion: Pledget was found to be useful for minimizing the difficulty in intracoproreal continuous gastrointestinal suturing and reducing the number of stapler cartilages used in intracorporeal anastomosis.

  • PDF