• 제목/요약/키워드: Surgical Operation

검색결과 2,168건 처리시간 0.025초

침(針)과 도(刀)를 이용한 수술법에 대한 문헌 조사 - 외과전문서적을 중심으로 - (A Research of Ancient operation through traditional medical documents)

  • 방성혜;차웅석;김남일
    • 한국의사학회지
    • /
    • 제20권2호
    • /
    • pp.81-86
    • /
    • 2007
  • In ancient East Asia surgical methods existed even before the modern surgical methods were introduced. These surgical methods were mainly used to treat tumor, bruises, and dermatosis. The methods include many techniques such as making incisions in the skin, tell when to operate, and the aftercare following an operation. The traditional ways are not practiced any more due to its being replaced by the anesthesia techniques originating from the West, but the ancient methods can still be found in documents and these methods can be reproduced through such documents. There is a possibility that this ancient method could replace the present day method because of its nature-friendly characteristic as well as its post-operation management.

  • PDF

개에서 성대 및 성대돌기의 고정에 의한 무성술 (Devocalization of Dogs by Fixation of Vocal Cords and Vocal Processes)

  • 정종태;원상철
    • 한국임상수의학회지
    • /
    • 제15권1호
    • /
    • pp.124-130
    • /
    • 1998
  • This study was performed to evaluate the new surgical technique for debarking. Of the 8 mongrel dogs which underwent devocalization, 4 heads (group 1) received complete surgical removal of the vocal cords and another 4 heads (group 2) received fixation of vocal cords and vocal processes onto the thyroid cartilage. Volume of each dogs' voices was measured by a sound level meter(Function A) over 7 months at intervals of 10 days. All experimental animals'hematological values were measured before operation and postoperative at 2i 5 and 10 days. The changes of volume of dogs'voices and hematological values were analyzed by paired t-test. The volume in the dogs'voices in each group after operation was significantly lower than that before operation. At this results we detected that devocalizing effect was the same in each group. Postoperative volume of dogs'voices in group 1 had a tendency to increaser but group 2 had a tendency to decrease. The number of erythrocytes at 2 days after operation was significantly fewer than those before operation in group 1, but the group 2 did not have significant changes. The number of leukocytes at 2 days after operation significantly increased from those before operation in group 11 but the group 2 did not have significant changes. It was concluded that the new surgical technique, fixation of vocal cords and vocal processes onto the thyroid cartilages could be available for the devocalization of dogs and for the prevention of postoperative inflammation and blood loss.

  • PDF

복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구 (Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument)

  • 김지언;이민철;이태경;최승욱;박민규
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

물과 솔 없이 사용하는 외과적 손 소독제 Chlorhexidine/Ethanol 혼합제와 Povidone-iodine의 소독 효과 (Evaluation of a Waterless, Scrubless Chlorhexidine Gluconate/Ethanol Surgical Scrub and Povidone-Iodine for Antimicrobial Efficacy)

  • 최정실
    • 대한간호학회지
    • /
    • 제38권1호
    • /
    • pp.39-44
    • /
    • 2008
  • Purpose: The purpose of this study was to compare 1% chlorhexidine-gluconate/61% ethanol (CHG/Ethanol) emollient and 7.5% povidone-iodine (PVI) scrub for antimicrobial, residual effect, and skin condition. Method: CHG/Ethanol emollient hand hygiene was performed waterless, and brushless by operating doctors and nurses (N=20). PVI hand washing was performed with water and a brush (N=20) for 5 min. The subjects were asked to press their left hand in hand-shaped agar before a surgical scrub, immediately after a surgical scrub and after the operation. The amount of isolated microorganisms were calculated by counting the number of divided areas($1{\times}1cm$, 160 cell) which were culture positive in the hand culture plate. The skin condition was evaluated. Result: The antimicrobial count of CHG/Ethanol emollient and PVI immediately post surgical scrub was 0.0 vs. 4.1 (p>.05), and after the operation was 0.1 vs. 37.8 (p>.05)respectively. The Residual effect of CHG/Ethanol emollient immediately post surgical scrub and after the operation were 0.0 vs. 0.1 (p>.05), and PVI were 4.1 vs. 37.8 (p>.05)respectively. The skin condition and satisfaction of CHG/Ethanol emollient was higher than PVI (p<.05). Conclusion: The antimicrobial effect between CHG/Ethanol emollient and PVI were the same. Considering skin condition, satisfaction and allergic reaction CHG/Ethanol emollient for surgical scrub is recommended in Korea.

수술유니트의 유형 및 규모 산정을 위한 건축계획 프로그램에 관한 연구 (A study on the Architectural Planning Program for the type and scale computation of Operating-Unit)

  • 채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권2호
    • /
    • pp.43-50
    • /
    • 2002
  • By reason of development of anesthesia, advent of new surgical operation type and change of hygiene criterion and economical index is increasing recently request about alteration of existing unit or new surgical operation-unit type. The purpose of this study is to provide of architectural planning program for the type decision and the scale computation of operating-unit in healthcare facilities. As a result of this study, presented program of six type according to surgical operation process including space and time side.

  • PDF

수술후 재발한 기흉의 임상적 고찰 (Clinical Evaluation of Recurrent Pneumothorax after Surgical Lnterventions)

  • 백효채
    • Journal of Chest Surgery
    • /
    • 제27권8호
    • /
    • pp.683-688
    • /
    • 1994
  • The most common cause of spontaneous pneumothorax is a ruptured bleb, which occurs mostly in young patients and they are usually treated by tube thoracostomy. Recurrence frequently occurs and these patients require some form of surgical intervention. From March 1990 to February 1994, we have experienced 19 cases of recurrent pneumothorax in 16 patients among 347 patients who underwent 423 surgical interventions. The name of first operation after thoracotomy were bullectomy in 4 cases, bullectomy and pleurodesis in 3 cases, bullectomy, pleurodesis in addition to application of tissue sealant in 1 case. Thoracoscopic operations were performed as follows: bullectomy in 2 cases,electroablation plus tissue sealant in 4 cases, electroablation, tissue sealant and pleurodesis in 1 case,and in 4 cases, only tissue sealant was applied. The average age of patients are 21.5 years, and bilaterally operated patients and patients. who received tissue sealant or tissue sealant plus electrocauterization only had higher incidence of recurrence. The patients who needed chest tube insertion longer than 5 days after the first operation were 52.6 %, and 82.3 % recurred within one month of the first operation.

  • PDF

중증 심부전 또는 심인성 악액질을 동반한 미숙아및 영아기 동맥관개존증에 대한 수술요법 (Surgical Treatment of Patent Ductus Arteriosus in Preterm and Infants with Severe Heart Failure and Cardiac Cachexia)

  • 이석재
    • Journal of Chest Surgery
    • /
    • 제26권12호
    • /
    • pp.915-919
    • /
    • 1993
  • The management of Patent Ductus Arteriosus[PDA] with heart failure and cardiac cachexia in premature infants have been a disturbing and controversial problem in the field of pediatric cardiovascular surgery.We analysed our experiences to determine the rationale of surgical closure of PDA in infants . During a period of 7 years from January 1986 to December 1992, 12 infants under 2 months of age underwent operations for "hemodynamically significant" PDA which had caused severe heart failure.There were 6 male and 6 female patients. Their mean gestational age was 33.8 weeks and their mean body weight was 1990 g. ranged from 710 g. to 2900 g. Mean age at operation was 28.5days. Seven patients had history of Indomethacin trial. All patients were operated with double ligation technique under general anesthesia.There was no mortality and blood transfusion was not necessary in any patient during the operation.In all cases, we could confirm the complete closure of PDA after operation by follow-up echocardiography.Two patients died during their hospital stay and 1 patient died at 6 months after operation. The causes of death were sepsis with congestive heart failure, necrotizing entero colitis and pneumonia respectively.We can not detect any operation related complication which resulted in permanent sequelae as well as delayed complications related to nerve damage. These results indicate that surgical ligation of PDA in infants with severe heart failure is relatively safe and effective.effective.

  • PDF

LC 직렬공진에 의한 전기 수술기 개발 (Development of electric surgical machine by LC series resonance)

  • 이오걸;김태우;송호신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.153-157
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows, Therefore, this treatise developed electricity living body formation operation appliance by home production, Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

직렬공진에 의한 피부 수술기 개발 (Development of skin surgical machine by series resonance method)

  • 이오걸;김상주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.127-132
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore, this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit. and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF