• Title/Summary/Keyword: Surge impedance

Search Result 70, Processing Time 0.031 seconds

Impedance and Surge Characteristics Analysis of PV Array (태양전지 어레이의 임피던스를 이용한 서지특성분석)

  • Lee, Ki-Ok;Choi, Ju-Yeop;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.208-211
    • /
    • 2004
  • Photovoltaic(PV) array, which is generally installed outside, has the possibility to be damaged by high voltage due to lightning. Because the electrical characteristics of PV array have not been fully identified by lightning yet, there is a very important issue whether PV array should be connected with ground or not. In this paper, a basic model of PV array is provided considering the PV cell's barrier capacitance and ground capacitance for analysis of electrical characteristics by lightning using PSCAD/EMTDC.

  • PDF

A Study on the Protection Methods of Sheath Circulating Current Reduction Device in Transient State (과도상태에서의 시스순환전류 저감장치 보호방안에 관한 연구)

  • Kang, Ji-Won;Jung, Chae-Kyun;Lee, Jong-Beom;Lee, Dong-Il;Jung, Gil-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.53-58
    • /
    • 2002
  • Sheath circulating current is increased as the change of sheath mutual impedance which is caused by imbalance of cable system, and different section length between joint box. If excessive current flows in sheath. sheath loss will be increased and then transmission capacity of underground transmission system is reduced. Accordingly, This paper proposed sheath current reduction device using resistor and reactor and proved the reduction effect of that device using EMTP/ATP. And also in this paper, when transients are occurred at the underground system with reduction device by ground fault and lightning surge. we analyzes transient effect of system variously. From this result. authors establish the protection methods of sheath circulating current reduction device.

  • PDF

A Simulation of Lightning Faults Reducing Effects on the 154 kV Transmission Tower by Auxiliary Grounding (보조접지선 시공에 의한 송전선로의 내뢰성 향상효과 모의)

  • Kwak, Joo-Sik;Shim, Jeong-Woon;Shim, Eung-Bo;Choi, Jong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1843-1846
    • /
    • 1997
  • This paper describes the fault reducing effects of the 154 kV transmission tower by auxiliary grounding from the top of the tower to ground. The grounding surge impedance of the auxiliary grounding system is calculated by CDEGS(:Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis), and the critical lightning back flashover current and arcing horn dynamic characteristics are simulated by EMTP/TACS(:Electromagnetic Transient Program/Transient Analysis of Control Systems). The calculated results of total LFOR(Lightning Flashover Rate) shows that the LFOR can be reduced from 5.2(count/100km. year) to 3.4 by auxiliary grounding on the 154 kV transmission tower with one ground wire shielding system.

  • PDF

Study on the Characteristics of Voice Communication System using Lights (빛을 이용한 음성통신시스템 특성에 관한 연구)

  • Yoon, Man-Young;Shin, Jong-Soon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.23 no.2
    • /
    • pp.15-23
    • /
    • 2005
  • This analog communication system overcomes a limit of the digital communication that used an electric power line, and shows a strong characteristic by decrease of impedance along a load or surge-voltage and the same noise. this system is to detect an sound signal added to light through an photo-sensor and a filter circuit. And a signal detected in this way is transmitted to sound through a speaker of an earphone again.

  • PDF

Impedance Analysis and Surge Characteristics of PV Array

  • Lee, Ki-Ok;So, Jeong-Hoon;Yu, Gwon-Jong;Park, Ju-Yeop
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.259-264
    • /
    • 2003
  • Photovoltaic (PV) array, which is generally installed outside, has the possibility of being damaged by high voltage due to lightning. primarily because the electrical characteristics of PV array have not been fully identified by lightning yet, there is a very important issue whether PV array should be connected with a ground or not. In this paper, a basic model of PV array is provided considering the PV cell's barrier capacitance and ground capacitance for analysis of electrical characteristics by lightning.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

Analysis on Effect of Surge Impedance Reduction according to Three Ground Wires (써지 임피던스 저감을 위한 가공지선 3조화 효과 분석)

  • Kang, Yeon-Woog;Min, Byeong-Wook;Kim, Tai-Young;Park, Bong-Gyu;Choi, Jin-Sung;Park, Kwang-Uk;Bae, Hyun-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.541-542
    • /
    • 2011
  • 한전의 가공 송전선로는 2010년 기준으로 약 12,990km(765 kV 송전선로 354 km, 345 kV 송전선로 약 3,868 km, 154 kV 송전선로 8,173 km, 66 kV 송전선로 : 약 595 km)가 설치되어 운전되고 있다. 이러한 송전선로는 평지, 구릉, 산악지 등에 설치됨으로써 자연환경에 크게 영향을 받는다. 특히 전 세계적으로 낙뢰에 의한 송전선로의 트립 고장이 전체 고장의 약 60%를 점유하는 것으로 보고되고 있으며, 낙뢰에 의한 고장을 최소화하기 위한 내뢰 설계를 시행하고 있다. 한전에서도 전압별 계통의 신뢰도와 경제성을 고려하여 765 kV 송전선로의 목표 사고율은 0.35[건/100 km 년], 345 kV 송전선로의 경우는 1.0[건/100 km 년], 154 kV 송전선로의 경우는 2.0[건/100 km 년] 이하의 목표 사고율을 설정하여 설계 운영하고 있다. 그러나 2000년 이후 낙뢰 발생 빈도가 증가하고 있으며, 낙뢰에 의한 고장 점유율도 약 75%로서 고품질 전력공급을 위한 내뢰 대책 수립의 검토가 요구되고 있다.

  • PDF

Output Filter Design for Conducted EMI Reduction of PWM Inverter-Fed AC Motor Drive System (PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구)

  • 김이훈;박규현;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.546-555
    • /
    • 2001
  • In this paper filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives are presented. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections ringing and the dv/dt, di/dt, at the motor terminals. Specially the output filter is used to limit the rate of the inverter output voltage and reduce common mode noise to the motor, The performance of the output filter is evaluated through simulations and experiment on PWM inverter-fed AC motor drive. An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board Finally, experimental result shows inverter output filter reduces more common mode voltage than low pass filter also reduce overoltage and ringing at the motor terminal.

  • PDF

Sintering and Electrical Properties of Mn-doped ZnO-$TeO_2$ Ceramics

  • Hong, Youn-Woo;Baek, Seung-Kyoung;Hwang, Hyun-Suk;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.49-49
    • /
    • 2008
  • ZnO-based varistors have been widely used for voltage stabilization or transient surge suppression in electric power systems and electronic circuits. Recently, It has reported that the varistor behavior with nonlinear coefficient of 6~17 in Mn-doped ZnO. In this study we have chosen the composition of ZnO-$TeO_2-Mn_3O_4$ (ZTM) system to the purpose of whether varistor behavior appeared in doped ZnO by the solid state sintering or not. We investigated the sintering and electric properties of 0.5~3.0 at% Mn doped ZnO-1.0 at% $TeO_2$ system. Electrical properties, such as current-voltage (I-V), capacitance-voltage (C-V), and impedance spectroscopy were conducted. $TeO_2$ itself melts at $732^{\circ}C$ in air but forms the $ZnTeO_3$ phase with ZnO as increasing temperature and therefore retards the densification of ZnO to $1000^{\circ}C$. The average grain size of sintered samples was at about $3{\mu}m$ and decreased with increasing Mn contents. It was found that a good varistor characteristics were developed in ZTM system sintered at $1100^{\circ}C$ (nonlinear coefficient $\alpha$ ~ 60). The results of C-V characteristics such as barrier height ($\Theta$), donor density ($N_d$), depletion layer (W), and interface state density ($N_t$) in ZTM ceramics were $4\times10^{17}cm^{-3}$, 0.7 V, 40 nm, and $1.6\times10^{12}cm^{-2}$, respectively. It will be discussed about the stability and homogeneity of grain boundaries using distribution parameter ($\alpha$) simulated with the Z(T)"-logf plots in ZTM system.

  • PDF