• Title/Summary/Keyword: Surfaced

Search Result 172, Processing Time 0.021 seconds

Tight Budgets and Roadway Maintenance: The Need for Further Study of the Conversion/Reconversion Scenario for Low-Volume Roadways (예산 및 도로 유지관리 : 저교통량 도로의 포장 변경을 위한 추가연구의 필요성)

  • Kim, Hyun Hwan;Humphries, Evan;Hu, Jiong;Lee, Soon Jae;Lee, Moon Sup
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-12
    • /
    • 2015
  • PURPOSES : This paper presents a description of the current issues facing road managers regarding the surface-type conversion of low-volume roads for cost savings. METHODS: The paper reviews previous works conducted toward this end, acknowledges gaps in the current research, and lays out what information is needed for further studies. RESULTS : If the cost to maintain an unsurfaced road is less than the cost of maintaining a surfaced road, then there is potential for cost savings for the management agency. However, the problem is bigger than simply maintaining the roads that already exist. If unsurfaced roads prove to be more economical than surfaced roads, then the cost to convert from a surfaced to an unsurfaced roadway, and vice versa, when necessary, must also be examined. CONCLUSIONS : No other studies have addressed the un-surfacing of a road for cost savings, and it is therefore unknown whether substantial savings can be realistically obtained by converting from a surfaced to an unsurfaced road. To determine whether a conversion policy would be a viable option, additional data and research are needed.

COMPARATIVE STUDY OF OSSEOINTEGRATION OF 4 DIFFERENT SURFACED IMPLANTS IN THE TIBIA OF DOGS (성견 경골에서 표면처리방법이 다른 4종의 임프란트 골유착에 관한 비교연구)

  • Hong, Who-Suk;Kim, Tae-Hee;Ryu, Seong-Hee;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.46-54
    • /
    • 2005
  • Purpose: This study was performed in order to compare the osseointegration of 4 different surfaced implants in the dog's tibia which has thick dense cortical bone and loose marrow space. Materials & methods: Four mongrel dogs and four different surface types of implants, smooth surfaced AVANA implants, RBM surfaced AVANA implants, HA-coated Steri-Oss implants and SLA Bicon implants, were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics: Control group, RBM group, HA group, and SLA group. Three implants of each group were installed into the metaphysis of tibia of adult dogs. The animals were sacrificed at 8 weeks after implantation. The undecalcified specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: Radiographically and histologically good osseointegration of implant was observed in the dense cortical bone, but poor osseointegration was observed in the marrow space. Histologically more bone apposition to implant surface was found in rough surfaced groups than the smooth surfaced, Control group. In histomorphometric findings of cortical bone the average bone-implant contact ratios of HA group (95.4%, p<0.01), RBM group (87.1%, p<0.05), and SLA group (86.0%, p<0.05) were significantly higher than that of Control group (75.9%). In marrow space the average bone-implant contact ratios of HA group (76.1%, p<0.01) and SLA group (45.4%, p<0.05) were significantly higher than that of Control group (29.6%). The ratio of RBM group was higher than that of Control group but there was no significantly difference between RBM group and Control group. Conclusion: These results suggest that the rough surfaced implants can obtain the better osseointegration than the smooth surfaced implant in the cortical and marrow space and that HA-coated implants can obtain the best osseointegration in the marrow space among them.

A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning (하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구)

  • Kim, Woo-Sung;An, Kyung-Mi;Sohn, Dong-Seok;Jung, Heui-Seung;Shin, Im-Hee
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

Mechanical Properties of Electro-Discharge-Sintered Porous Titanium Implants (전기방전소결에 의해 제조된 다공성 Titanium 임플란트의 기계적 특성)

  • Hyun, C.Y.;Huh, J.K.;Lee, W.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.173-177
    • /
    • 2006
  • Porous surfaced Ti implant compacts were fabricated by electro-discharging-sintering (EDS) of atomized spherical Ti powders. Powders of $50-100{\mu}m$ in diameter were vibratarily settled into a quarts tube and subject to a high voltage and high density current pulse in Ar atmosphere. Single pulse of 0.7 to 2.0 kJ/0.7 gpowder, from 150, 300, and $450{\mu}F$ capacitors was applied in less than $400{\mu}sec$ to produce twelve different porous-surfaced Ti implant compacts. The solid core formed in the center of the compact shows similar microstructure of cp Ti which was annealed and quenched in water. Hardness value at the solid core was much higher than that at the particle interface and particles in the porous layer, which can be attributed to both heat treatment and work hardening effects induced by EDS. Compression tests were made to evaluate the mechanical properties of the EDS compacts. The compressive yield strength was in a range of 12 to 304MPa which significantly depends on input energy. Selected porous-surfaced Ti-6Al-4V dental implant compacts with a solid core have much higher compressive strengths compared to the human teeth and sintered Ti dental implants fabricated by conventional sintering process.

RETROSPECTIVE STUDY OF SINTERED POROUS-SURFACED DENTAL IMPLANTS IN RESTORING THE POSTERIOR MAXILLA (상악 구치부에 식립된 엔도포아 임플란트의 후향적 연구)

  • Kim, Sang-Soo;Ahn, Mi-Ra;Lee, Won-Hyuk;Jung, Heui-Seung;Shin, Im-Hee;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.361-366
    • /
    • 2009
  • Purpose: The purpose of this retrospective report was to analyze long-term survival rate of sintered porous-surfaced dental implant ($Endopore^{(R)}$ Dental Implant system, Innova Corporation, Toronto, ON, Canada). Methods: 61 partially edentulous patients were received a total of 127 Endopore dental implants in the maxilla. Of the 127 implants, 24 implants were restored with individual (ie, non-splinted) crowns, while 103 implants were splinted to other implants. Medical records and radiographs were evaluated and analyzed by the cumulative survival rate, location of implants, implants length and diameter, crown/implant ratio and whether the implant was splinted. Chi squire test was used statistically. Result: Of the 127 implants, 8 implants (6.3%) were removed and and cumulative survival rate was 93.7%. Conclusion: Endopore implants showed satisfactory results after up to 8 years function periods in the edentulous posterior maxilla.

Porous and Porous Surfaced Ti-6Al-4V Implants Fabricated by Electro-Discharge-Sintering : (2) Hardness and Compressive Strength (전기방전소결에 의해 제조된 다공성 및 다공성 표면을 갖는 Ti-6Al-4V 임플란트 : (2) 경도 및 압축강도)

  • Hyun, C. Y.;Huh, J. K.;Lee, W. H.
    • Journal of Powder Materials
    • /
    • v.12 no.5 s.52
    • /
    • pp.332-335
    • /
    • 2005
  • Porous and porous surfaced Ti-6Al-4V implant compacts were fabricated by electro-discharge-sintering (EDS) of atomized spherical Ti-6Al-4V powders with a diameter of $100-150\;{\mu}m$, The solid core formed in the center of the compact after discharge was composed of acicular ${\alpha}+{\beta}$ Widmanstatten grains, The hardness value at the solid core was much higher than that at the particle interface or particles in the porous layer, which can be attributed to both heat treatment and work hardening effects induced from EDS, The compressive yield strength was in a range of 19 to 436 MPa which significantly depends on both input energy and capacitance, Selected porous-surfaced Ti-6Al-4V implant compacts with a solid core have much higher compressive strengths compared to the human teeth and sintered Ti dental implants.

A Study on Torque Ripple Reduction of the Multi-degree of Freedom Operated Spherical Motor (다자유도 구동 스피리컬 모터의 토크리플 저감 설계에 관한 연구)

  • Kang, Dong-Woo;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1541-1543
    • /
    • 2013
  • This paper presents a spherical motor which can control in multi-degree of freedom operation. The spherical motor has been researched by many types of structure. Thhis paper shows a spherical shaped airgap and surfaced permanent magnets. Especially, The motor consists of dual rotor cores. Unlike a cylindrical motor, the spherical motor design can be considered with azimuth direction on spherical coordinates. Therefore the permanent magnet surfaced on the rotor need to be designed optimally in order to generate a sinusoidal magnetic flux density in the airgap. This paper presents results of optimal design for reducing torque ripple of the multi-degree of freedom spherical motor.

Electron Microscopical Observations of Hepatic Cells in Korean Native Goat Injected with Clostridium perfringens Toxin (Clostridium perfringens독소(毒素)를 주사(注射)한 재래산양(在來山羊) 간장(肝臟)의 전자현미경적(電子顯微鏡的) 관찰(觀察))

  • Lee, Cha-Soo
    • Korean Journal of Veterinary Research
    • /
    • v.22 no.2
    • /
    • pp.187-195
    • /
    • 1982
  • This paper dealt with the light microscopical and electron microscopical findings on the morphological changes of the liver of Korean native goat injected with toxin (culture filtrate) of Clostridium perfringens which was isolated from Korean native cattle died of acute Clostridium perfringens enterotoxemia. The results observed are summarized as follows. In the microscopical findings, hyperemia and minute hemorrhage of the liver parenchyma, dilatation of hepatic central vein and centrilobular necrosis of liver, cloudy swelling and hydropic degeneration of hepatic cells, and appearance of light eosinophilic granular bodies in the vacuoles were recognized. In the electron microscopical findings, appearance of pinocytotic vesicle (coated vesicle), fusion of these vesicles, formation of vacuole and accumulation of minute granular proteinous materials in the vacuole were observed in the hepatic cells. Decreased number of glycogen granules, swelling and destruction of mitochondria, proliferation of smooth-surfaced endoplasmic reticulum, enlargement of rough-surfaced endoplasmic reticulum, dispersal of thready agranular membranous structure and appearance of secondary lysosome were recognized in the hepatic cell cytoplasm.

  • PDF

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

The Changes of Rough Surfaced Endoplasmic Reticulm of Lymph Node Cells Stimulated by Antigen (항원성 자극을 받은 임파절세포의 Rough Surfaced Endoplasmic Reticulum 의 변화)

  • Lee Chang-Soo;Kwon Sae-Hoon;Sohn Tae-Joong
    • Applied Microscopy
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 1973
  • The changes of rough surfaced endoplasmic reticulum of plasma cells in the regional lymph node after injection of Bovine Gamma Globulin summarized as follow: The rough ER of plasma cells before antigenic stimulation shows flattened sac but changed to vesicular at 3rd day and vacuolar at 7th to 10th day. lntradisternal granules are appeared within the lumina or rough ER at 7th to 10th day. The rough ER is changed to distended sac or flattened sac at 20th day. The results suggest that normally flattened sac of rough ER is changed to vesicular and then to vacuolar after antigenic stimulation. But they are returned to distended sac or flattened sac with disappearance of antigenic stimuli.

  • PDF