• 제목/요약/키워드: Surface-micromachining

검색결과 180건 처리시간 0.028초

다결정 SiC 마이크로 공진기의 제작과 그 특성 (Fabrication and characteristics of polycrystalline SiC micro resonators)

  • 정귀상;이태원
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.425-428
    • /
    • 2008
  • This paper describes the resonant characteristics of polycrystalline SiC micro resonators. The $1{\mu}m$ thick polycrystalline 3C-SiC cantilevers with different lengths were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonance was measured by a laser vibrometer in vacuum at room temperature. For the $100{\sim}40{\mu}m$ long cantilevers, the fundamental frequency appeared at $147.2kHz{\sim}856.3kHz$. The $100{\mu}m$ and $80{\mu}m$ long cantilevers have second mode resonant frequency at 857.5.kHz and 1.14.MHz, respectively. Therefore, polycrystalline 3C-SiC resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

비 접촉 각도 센서 응용을 위한 수직 Hall 소자의 제작 (The Fabrications of Vertical Trench Hall-Effect Device for Non-contact Angular Position Sensing Applications)

  • 박병휘;정우철;남태철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.251-253
    • /
    • 2002
  • We have fabricated a novel Vertical Trench Hall-Effect Device sensitive to the magnetic field parallel to the sensor chip surface for non-contact angular position sensing applications. The Vertical Trench Hall-Effect Device is built on SOI wafer which is produced by silicon direct bonding technology using bulk micromachining, where buried $SiO_2$ layer and surround trench define active device volume. Sensitivity up to 150 V/AT is measured.

  • PDF

대기중 나노초 펄스레이저 어블레이션의 수치계산 (Numerical simlation of nanosecond pulsed laser ablation in air)

  • 오부국;김동식
    • 한국레이저가공학회지
    • /
    • 제6권3호
    • /
    • pp.37-45
    • /
    • 2003
  • Pulsed laser ablation is important in a variety of engineering applications involving precise removal of materials in laser micromachining and laser treatment of bio-materials. Particularly, detailed numerical simulation of complex laser ablation phenomena in air, taking the interaction between ablation plume and air into account, is required for many practical applications. In this paper, high-power pulsed laser ablation under atmospheric pressure is studied with emphasis on the vaporization model, especially recondensation ratio over the Knudsen layer. Furthermore, parametric studies are carried out to analyze the effect of laser fluence and background pressure on surface ablation and the dynamics of ablation plume. In the numerical calculation, the temperature, pressure, density, and vaporization flux on a solid substrate are obtained by a heat-transfer computation code based on the enthalpy method. The plume dynamics is calculated considering the effect of mass diffusion into the ambient air and plasma shielding. To verify the computation results, experiments for measuring the propagation of a laser induced shock wave are conducted as well.

  • PDF

표면 미세 가공된 측면형 전계 방출 소자를 이용한 초소형 진공 센서의 제작 (Fabrication of Micro-Vacuum Sensor using Surface-Macromachined Lateral-type Field Emitter Device)

  • 박흥우;주병권;이윤희;박정호;오명환
    • 센서학회지
    • /
    • 제9권3호
    • /
    • pp.182-189
    • /
    • 2000
  • 미소 공간 내의 진공도를 측정하기 위하여 마이크로 진공 센서를 제작하였다. 동작 원리로서 전계 방출 전류가 진공도에 의존한다는 점을 이용하였고, 이를 위해 측면형 실리콘 전계 방출 소자를 제작하였다. 음극과 게이트, 그리고 양극을 분리하기 위하여 표면 미세가공을 이용하였으며, 제작된 소자는 $10^{-5}{\sim}10^{-8}\;Torr$ 범위의 진공도에서 $1.20{\sim}2.42\;{\mu}A$ 범위의 방출 전류 변화를 보였다.

  • PDF

원자현미경을 이용한 생체물질의 접착력 측정기술 개발 (Novel measuring technique for biological adhesion forces using AFM)

  • 김성주;문원규;전종협
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.641-644
    • /
    • 2005
  • The study on the interaction forces of some biological materials is important to understanding biological phenomena and their application to practical purpose. This paper introduces a measuring technique for biological adhesive forces using the AFM(Atomic Force Microscope). Since no standardized thesis on adhesive forces exist, the adhesive forces is defined as adhesive forces against a hardened surface of biological materials. To grant the results are meaningful, which is based on the understanding the surface characteristics of biological materials using the AFM, a nominal value of average adhesive force per unit area should be measured. Therefore the modified AFM probe with small micro glass bead was proposed so that it can guarantee the required contact area for measuring the average adhesive forces. A pyrex glass substrate with circular patterns, which was fabricated by micromachining technique, is introduced in order to controll the contact area. The two types of mussel adhesive proteins, Celltak and recombinant-MGFP5, were tested by the proposed measuring method. The test results show that the adhesive force of the mussel adhesive proteins can be reliably measured by use of this method.

  • PDF

레이저 유도에칭을 이용한 티타늄 미세채널 제조 (Fabrication of Titanium Microchannels by using Ar+ Laser-assited Wet Etching)

  • 손승우;이민규;정성호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.709-713
    • /
    • 2004
  • Characteristics of laser-assisted wet etching of titanium in phosphoric acid were investigated to examine the feasibility of this method for fabrication of high aspect ratio microchannels. Laser power, number of scans, etchant concentration, position of beam waist and scanning speed were taken into consideration as the major process parameters exerting the temperature distribution and the cross sectional profile of etched channels. Experimental results indicated that laser power influences on both etch width and depth while number of scans and scanning speed mainly affect on the etch depth. At a low etchant concentration, the cross sectional profile of an etched channel becomes a U-shape but it gradually turns into a V-shape as the concentration increases. On the other hand, surface of the laser beam focus with respect to the sample surface is found to be a key factor determining the bubble dynamics and thus the process stability. It is demonstrated that metallic microchannels with different cross sectional profiles can be fabricated by properly controlling the process parameters. Microchannels of aspect ratio up to 8 with the width and depth ranges of 8∼32 m and 50∼300 m, respectively, were fabricated.

  • PDF

HF 증기상 식각과 열처리를 이용한 다결정 규소 미세 구조체의 제작 (Fabrication of Polysilicon Microstructures Using Vapor-phase HF Etching and Annealing Techniques)

  • 박경호;이춘수;정영이;이재열;이용일;최부연;이종현;유형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.603-605
    • /
    • 1995
  • We present a novel method. to fabricate surface micromachined structures without their sticking on the substrate. An anhydrous HF/$CH_3OH$ vapor-phase etching (VPE) of sacrificial $SiO_2$ layers was employed to release 0.5-2 {\mu}m$ thick polysilicon cantilevers. The fabricated structures were observed using scanning electron microscope and 3-dimensional optical microscope. The results show that we can successfully make cantilever beams up to 1200{\mu}m$ long without sticking. Annealing effects on residual stress of polysilicon microstructures were also investigated. Anneal ins at 1100$^{\circ}C$ for 1 hour was found to be effective to release the residual stress of the polysilicon microstructures. These VPE and anneal ins techniques will be useful in surface micromachining technologies.

  • PDF

표면 및 몸체 미세 가공 기술로 제작된 대기압에서 동작하는 전자력 검출형 각속도계의 연구 (A Surface-Bulk Micromachined Electromagnetic Gyroscope Operating at Atmospheric Pressure)

  • 김성혁;김용권;송진우;이장규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2230-2232
    • /
    • 2000
  • This paper reports an electrostatically driven and electromagnetically sensed planar vibratory gyroscope based on a surface-bulk combined micromachining. The fabricated structure has comb electrodes which are 400${\mu}m$ thick, 18${\mu}m$ wide, 600${\mu}m$ long and separated by 7${\mu}m$ so that the height-gap ratio is about 57. It also has electroplated gold springs which are 15${\mu}m$ wide, 14${\mu}m$ thick and 500${\mu}m$ long on both sides of the seismic mass. The open-loop characteristics of fabricated gyroscope at atmospheric pressure are measured on a rate table. The fabricated gyroscope has a sensitivity of 30mV/deg/sec, and a resolution of 0.1deg/sec at atmospheric pressure. It is expected that non linearity of full scale output is less than 0.8% with. the dynamic range of $\pm$500deg/sec.

  • PDF

다결정 3C-SiC 멤브레인 위에 균일한 온도분포를 갖는 마이크로 히터의 제작과 그 특성 (Fabrication of micro heaters with uniform-temperature area on poly 3C-SiC membrane and its characteristics)

  • 정귀상;정재민
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.349-352
    • /
    • 2009
  • This paper describes the fabrication and characteristics of micro heaters built on AlN($0.1{\mu}m$)/3C-SiC($1{\mu}m$) suspended membranes by surface micromachining technology. In this work, 3C-SiC and AlN films are used for high temperature environments. Pt thin film was used as micro heaters and temperature sensor materials. The resistance of temperature sensor and the power consumption of micro heaters were measured and calculated. The heater is designed for operating temperature up to about $800^{\circ}C$ and can be operated at about $500^{\circ}C$ with a power of 312 mW. The thermal coefficient of the resistance(TCR) of fabricated Pt resistance of temperature detector(RTD)'s is 3174.64 ppm/$^{\circ}C$. A thermal distribution measured by IR thermovision is uniform on the membrane surface.