화학흡착(CVD)법에 의한 TiC 흡착 시 모재가 피복 길항합금의 항면력 및 접착력에 미치는 영향 (Effects of Composition of Substrate on Transverse Rupture Strength and Bonding Strength of Cemented Carbide Coated with Titanium Carbide by CVD Process)

  • 이건우;오재현
    • 한국표면공학회지
    • /
    • 제24권1호
    • /
    • pp.8-8
    • /
    • 1991
  • To investigate the effects of substrate on transverse-rupture strength(TRS) and bonding strength between substrate and TiC layer coated by CVD, two kinds of substrate (substrate A:WC-9.5wt%Co-MC*[low C], substrate B: WC-6wt% Co-MC*[high C] were studied in terms of Cobalt and C contents respectively. For preparation of test samples the coating parameters of deposition time, deposition temperature and deposition pressure were varied. The result show that the carbon contents in substrates have greater effects on the TRS of the CVD TiC coated cemented carbide than Co contents in substrates.

Fabrication Process of Light Emitting Diodes Using CdSe/CdS/ZnS Quantum Dot

  • Cho, Nam Kwang;Kang, Seong Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.428-428
    • /
    • 2013
  • Red color light emitting diodes were fabricated using CdSe/CdS/ZnS quantum dots (QDs). Patterned indium-tin-oxide (ITO) was used as a transparent anode, and oxygen plasma treatment on a surface of ITO was performed. Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) was spin coated on the ITO surface as a hole injection layer. Then CdSe/CdS/ZnS QDs was spin coated and thermal treatment was performed for the cross-linking of QDs. TiO2 was coated on the QDs as an electron transport layer, and 150 nm of aluminum cathode was formed using thermal evaporator and shadow mask. The device shows a pure red color emission at 606 nm wavelength. Device characteristics will be presented in detail.

  • PDF

Effect of Titanium Coating on Cell Adhesion and Extracellular Matrix Formation in Human Osteoblast-like MG-63 Cells

  • Lee, Jae-Bum;Seo, Sang-Hui;Kim, Yu-Ri;Shin, Sang-Wan;Kim, Meyoung-Kon;Ryu, Jae-Jun
    • Molecular & Cellular Toxicology
    • /
    • 제4권3호
    • /
    • pp.192-198
    • /
    • 2008
  • A variety of titanium (Ti) and its alloys are used in the clinical procedures of bone regeneration for periodontal and dental implant therapies. This study was performed to determine the effect of different surface dental implant materials on biologic responses of a MG-63 human osteoblast-like cell line. MG-63 cells were cultured on Ti coated with hydroxyapatite (HA), calcium metaphosphate (CMP), anodized (A), which compared with non-coated Ti (control). The appearances of surface of dental implant materials and the morphology of these cells were assessed by scanning electron microscopy (SEM). The gene expression profiles of MG-63 cells cultured on Ti were examined by human cDNA microarray (1,152 elements). The expression of several genes was up- and down-regulated by different surfaces of dental implant materials. Interesting, the genes correlated with cellular adhesion and extra cellular matrix (ECM) formation were enhanced, in accordance surface morphology of the dental implant materials used.

Performance Characteristics of CVD Diamond Cutting Tools

  • Oles, E.J.;Cackowski, V.J.
    • The Korean Journal of Ceramics
    • /
    • 제2권4호
    • /
    • pp.203-211
    • /
    • 1996
  • CVD diamond tools are becoming more widely used in industry as an economic alternative to polycrystalline diamond (PCD) for machining non-ferrous and non-metallic materials. Although CVD diamond-sheet tools have been on the market for several years, diamond-coated carbide inserts have become available only recently, with the successful resolution of long-standing adhesion problems. Diamond coating morphology on the rake surface of the tool affects chip formation favorably, whereas a microscopically rough, faceted morphology on the flank surface of the tool produces a rough workpiece finish. Workpiece finish can be improved by using a coated tool with a larger nose radius. The tool life provided by diamond-coated tools(~30 $\mu\textrm{m}$ thick) can meet or exceed that of PCD tools, depending on the characteristics of the workpiece material. When using diamond-coated carbide tools in milling, a sharp-edged PCD tool should be used in the wiper position of the cutter to minimize workpiece roughness and burr formation.

  • PDF

정전 분무 공정을 이용한 Fecralloy 나노 입자가 코팅된 Fecralloy Foil의 제조 (Fabrication of Fecralloy Foil Coated by Fecralloy Nanoparticles Using Electrospray Processing)

  • 윤중열;양상선;구혜영;이혜문
    • 한국분말재료학회지
    • /
    • 제18권6호
    • /
    • pp.526-531
    • /
    • 2011
  • Fecralloy is the promising materials for high temperature exhaust filtering system due to the excellent its oxidation resistance property. In this research, Fecralloy nanoparticles coated Fecralloy thin foil was prepared by a single nozzle electrospray system in order to increase surface area of Fecralloy foil. Fecralloy nanoparticles were fabricated by electrical wire explosion method in ethanol using Fecralloy wires as a source material. Electrospray modes with applied D.C voltages to Fecralloy colloidal solution were investigated to make a stable cone-jet mode. Coated layers with and without additional heat treatment were observed by FE-SEM (field emission-scanning electron microscope) and tape test for evaluating their adhesion to substrate were performed as well.

Spectroscopic characterization of electroluminescent ZnS:Cu,Cl phosphor coated by sol-gel process

  • Lee, You-Hui;Han, Chi-Hwan;Han, Sang-Do;Chang, Mi-Youn;Sharma, Gaytri.;Park, Youn-Bong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1323-1326
    • /
    • 2005
  • The photoluminescence, electroluminescence and surface properties of ZnS:Cu,Cl phosphor coated by sol-gel process were studies. Na-silicate was used as precursor coating material. pH of solution and the concentration of Na-silicate are the important conditions to obtain the uniform coating on the phosphors. Also, the electroluminescent devices were made with Na-silicate coated phosphor. The spectroscopic characterization is performed by photospectrometer.

  • PDF

EFFECT OF TITANIUM SURFACE ROUGHNESS ON CELL ADHESION OF HUMAN OSTEOBLAST-LIKE CELLS (MG63)

  • Yim Soon-Ho
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.261-266
    • /
    • 2004
  • Statement of problem. The effects of surface roughness have not or insufficiently been analyzed on earlier events such as cell adhesion though cell behavior most germane to implant performance is cell adhesion. Purpose. The purpose of this study was to evaluate cell adhesion of osteoblast-like cells (MG63) onto three types of titanium disks with varying roughness using the Elisa assay. Materials and methods. Representative disks from each group (SLA, HA, machined) were subjected to surface analysis and surface roughness was measured by the optical interferometer (Accura 2000, Intekplus Co., Seoul, Korea). Following this, MG63 cells were cultured on the titanium disks and released. Cell adhesion measurements using the Elisa assay were performed specifically at three points: after 24, 48, and 72 hours of culture. Results. Among the 3 types of surface analyzed, the SLA surface was the roughest with a Ra value of $1.114{\mu}m$ followed by HA coated surface and machined surface, consecutively. The optical density values for the SLA surface group was significantly higher than that of the machined and HA coated surface groups following 24 and 48 hours of culture. The cell culture on HA coated surface showed significantly higher values compared to the machined surface following 24, 48 and 72 hours of culture. Conclusion. The results suggest that surface treatment of titanium surfaces enhanced cell adhesion of human osteoblast-like cells (MG63).

A Composite of Metal and Polymer Films: Thin Nickel Film Coated on a Polypropylene Film after Atmospheric Plasma Induced Surface Modification

  • Song, Ho-Shik;Choi, Jin-Moon;Kim, Tae-Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권3호
    • /
    • pp.110-114
    • /
    • 2011
  • Polymeric films of high chemical stability and mechanical strength covered with a thin metallic film have been extensively used in various fields as electric and electronic materials. In this study, we have chosen polypropylene (PP) as the polymer due to its outstanding chemical resistance and good creep resistance. We coated thin nickel film on PP films by the electroless plating process. The surfaces of PP films were pre-treated and modified to increase the adhesion strength of metal layer on PP films, prior to the plating process, by an environment-friendly process with atmospheric plasma generated using dielectric barrier discharges in air. The surface morphologies of the PP films were observed before and after the surface modification process using a scanning electron microscope (SEM). The static contact angles were measured with deionized water droplets. The cross-sectional images of the PP films coated with thin metal film were taken with SEM to see the combined state between metallic and PP films. The adhesion strength of the metallic thin films on the PP films was confirmed by the thermal shock test and the cross-cutting and peel test. In conclusion, we made a composite material of metallic and polymeric films of high adhesion strength.

전기수력학적 분무에서 노즐재질이 입경분포에 미치는 영향 (Effect of Nozzle Material on Drop Size Distribution in Electrohydrodynamic Spraying)

  • 김명찬;이상용
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1451-1457
    • /
    • 2002
  • When an aqueous liquid such as water having high electric conductivity and high surface tension is discharged from a nozzle under a strong DC electric field, fine drops ranging from 30 to 450 microns can be obtained only through the spindle mode. In the present study, effects of the electric conductivity and the surface wettability of nozzle materials on formation of drops with this mode were investigated. For that, three nozzles with the same size but with different materials were prepared and tested; a stainless steel needle, and a plain and a metal (gold)-coated (except for the tip portion) silica needles. Uniform drops were obtained with the gold-coated silica nozzle over the wider range of the DC voltage input. That is, formation of the liquid cone and detachment of the liquid spindle (ligament) can be more stabilized and frequent with the needles having high electric conductivity but with low surface wettability at their tips.