• 제목/요약/키워드: Surface resistivity

검색결과 995건 처리시간 0.031초

Correlation Between Bulk and Surface Resistivity of Concrete

  • Ghosh, Pratanu;Tran, Quang
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권1호
    • /
    • pp.119-132
    • /
    • 2015
  • Electrical resistivity is an important physical property of portland cement concrete which is directly related to chloride induced corrosion process. This study examined the electrical surface resistivity (SR) and bulk electrical resistivity (BR) of concrete cylinders for various binary and ternary based high-performance concrete (HPC) mixtures from 7 to 161 days. Two different types of instruments were utilized for this investigation and they were 4 point Wenner probe meter for SR and Merlin conductivity tester for bulk resistivity measurements. Chronological development of electrical resistivity as well as correlation between two types of resistivity on several days was established for all concrete mixtures. The ratio of experimental surface resistance to bulk resistance and corresponding resistivity was computed and compared with theoretical values. Results depicted that bulk and SR are well correlated for different groups of HPC mixtures and these mixtures have attained higher range of electrical resistivity for both types of measurements. In addition, this study presents distribution of surface and bulk resistivity in different permeability classes as proposed by Florida Department of Transportation (FDOT) specification from 7 to 161 days. Furthermore, electrical resistivity data for several HPC mixtures and testing procedure provide multiple promising options for long lasting bridge decks against chloride induced corrosion due to its ease of implementation, repeatability, non-destructive nature, and low cost.

PE 및 PP혼합 재료의 표면저항에 미치는 습도효과 (Humidity effects on surface resistivities in PE and PP mixtures)

  • 강전홍;유황민;김한준;한상옥;김종석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.424-426
    • /
    • 2002
  • The surface and volume resistivity in the polymers, PE(polyethylene) and PP(polypropylene) mixtures are tested and measured by the ASTM D257(KS M3015) standard. Humidity effects on surface and volume resistivity in two polymers have been studied qualitatively at room temperature. The results of resistivity in these polymers show that the values of surface resistivity (and volume resistivity) at the humidity of 90% are remarkably small compared with those at the humidity of 50%, independing on applied voltage. When we varied the humidity in two polymers, it was found to takes many hours to recover into original surface resistivity (and volume resistivity) of these polymers.

  • PDF

Testing of the permeability of concrete box beam with ion transport method in service

  • Wang, Jia Chun
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.461-471
    • /
    • 2015
  • The permeability is the most direct indicator to reflect the durability of concrete, and the testing methods based on external electric field can be used to evaluate concrete permeability rapidly. This study aims to use an experiment method to accurately predict the permeability of concrete box beam during service. The ion migration experiments and concrete surface resistivity are measured to evaluate permeability of five concrete box beams, and the relations between these results in service concrete and electric flux after 6 hours by ASTM C1202 in the laboratory are analyzed. The chloride diffusion coefficient of concrete, concrete surface resistivity and concrete 6 hours charge have good correlation relationship, which denote that the chloride diffusion coefficient and the surface resistivity of concrete are effective for evaluating the durability of concrete structures. The chloride diffusion coefficient of concrete is directly evaluated permeability of concrete box beam in service and may be used to predict the service life, which is fit to engineering applications and the concrete box beam is non-destructive. The concrete surface resistivity is easier available than the chloride diffusion coefficient, but it is directly not used to calculate the service life. Therefore the mathematical relation of the concrete surface resistivity and the concrete chloride diffusion coefficient need to be found, which the service life of reinforced concrete is obtained by the concrete surface resistivity.

아르곤 플라즈마처리에 의한 다결정 $Si_{1-x}Ge_x$박막의 표면거칠기 개선 (The Improvement of Surface Roughness of Poly-$Si_{1-x}Ge_x$Thin Film Using Ar Plasma Treatment)

  • 이승호;소명기
    • 한국세라믹학회지
    • /
    • 제34권11호
    • /
    • pp.1121-1128
    • /
    • 1997
  • In this study, the Ar plasma treatment was used to improve the surface roughness of Poly-Si1-xGex thin film deposited by RTCVD. The surface roughness and the resistivity of Si1-xGex thin film were investigated with variation of Ar plasma treatment parameters (electrode distance, working pressure, time, substrate temperature and R.F power). When the Ar plasma treatment was used, the cluster size decreased by the surface etching effect due to the increasing surface collision energy of particles (ion, neutral atom) in plasma under the conditions of decreasing electrode distance and increasing pressure, time, temperature, and R. F power. Although the surface roughness value decreased by the reduction of the cluster size due to surface etching effect, however, the resistivity increased. This may be due to the surface damage caused by the increasing surface collision energy. It was concluded that the surface roughness could be improved by the Ar plasma treatment, while the resistivity was increased by the surface damage on the substrate.

  • PDF

2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석 (Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model)

  • 이복희;김태기;조용승;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

Electrical Properties of the Transparent Conducting Oxide Layers of Al-doped ZnO and WO3 Prepared by rf Sputtering Process

  • 강동수;김희성;이붕주;신백균
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.316-316
    • /
    • 2014
  • Two different transparent conducting oxide (TCO) layers of Al-doped ZnO (AZO) and $WO_3$ were prepared by a rf sputtering process. Working pressure, deposition time, and target-to-substrate distance were varied for the sputtering process to improve electrical properties of the resulting layer. Thickness of the TCO layers was measured by a profile meter of ${\alpha}$-step. To evaluate the electrical conductivity, surface resistivity of the TCO layers was measured by a four-point probe technique. Decrease of the working pressure resulted in increase of deposition rate and decrease of surface resistivity of the resulting layer. Increase of the layer thickness due to increased deposition time resulted in decrease of surface resistivity of the resulting layer. The shorter the target-to-substrate distance was, the lower was the surface resistivity of the resulting layer.

  • PDF

코로나 방전에 따른 실리콘 고무의 표면 특성 (Surface Characteristics of Silicone Rubber Processes by Corona Discharges)

  • 한동희;조한구;강동필;민경은
    • 한국전기전자재료학회논문지
    • /
    • 제15권2호
    • /
    • pp.133-140
    • /
    • 2002
  • This paper aims to investigate the effect of silicone oils as processing agent affecting the loss and recovery of hydrophobicity. The recovery of hydrophobicity was evaluated by the measurement of the surface electrical resistivity and the contact angle on the SIR surface. Two kinds of silicone oils (1 and 2) having different molecular weight were selected under a consideration of hydrophobicity and processability. SIR specimens were exposed to corona discharges in air and the specimens were analyzed with contact angle and surface resistance measurements. It was observed that the contact angle and the surface resistivity of SIR increase gradually with testing time. The fast recovery of hydrophobicity of SIR, expressed by the increment of contact angle and surface resistivity, was showed in SIR2 containing silicone oil 2.

강섬유 보강콘크리트의 강섬유 분산이 표면전기저항에 미치는 영향 (Effect of Steel Fiber Distribution in Steel Fiber-reinforced Concrete on Surface Electrical Resistivity)

  • 김성도;문도영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.106-113
    • /
    • 2013
  • 콘크리트의 투수성능을 평가하는 여러 가지 비파괴시험방법 중의 하나는 표면전기저항을 측정하는 것이다. 그러나 콘크리트내에 강섬유로 인한 판단의 오류가 발생할 수 있기 때문에 강섬유 보강콘크리트에 본 표면전기저항측정방법을 적용하기에는 한계가 있다. 본 연구에서는 강섬유보강 콘크리트의 강섬유 분산도가 표면전기저항에 미치는 영향을 실험적으로 고찰하였다. 3개의 정방형 및 원형 실험체의 4개면에서의 저항치를 3번 반복하여 측정하였으며, 서로 비교하였다. 측정결과에 의하면, 원형실험체를 이용한 실험결과가 정방형 실험체의 결과에 비하여 강섬유의 영향을 일관되게 나타내고 있는 것으로 확인되었다. 또한, 강섬유의 분산도는 강섬유 혼입량에 비하여 측정결과에 미치는 영향이 미미한 것으로 나타났다. 결론적으로, 표면전기저항측정을 이용한 비파괴 평가법은 0.5%까지의 강섬유를 포함한 SFRC의 투수성 평가에 적용될 수 있는 것으로 판단된다.

Surface Characterization of Silicone Rubber for Outdoor Insulation by Measurement of Surface Voltage Decay

  • Youn, Bok-Hee;Huh, Chang-Su;Cho, Han-Gu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제12C권4호
    • /
    • pp.214-219
    • /
    • 2002
  • The influence of ultraviolet (UV) irradiation and corona on the surface degradation of high temperature vulcanized (HTV) silicone rubber used for outdoor insulation through measuring surface voltage decay after corona charging, surface resistivity, contact angle and X-ray photoelectron spectroscopy (XPS) analysis was studied. The surface resistivity calculated by the surface voltage decay was compared with a value directly obtained from the three electrode method having the guard ring electrode. A good agreement between the two methods for surface resistivity was obtained. UV treated specimens showed the slower decrease of surface voltage decay, while the corona exposed specimens showed a dramatically faster decrease. Although both artificial treatments cause the same oxidative products, which was confirmed with XPS, we could distinguish the difference between the reactions of the two treatments by monitoring the surface voltage decay on corona-charged specimen. In addition, we could derive the specific surface states of the silicone rubber treated by accelerated artificial aging factors and the degradation process.

Cu(Mg) alloy의 비저항에 영향을 미치는 인자에 대한 연구 (A study on the factors affecting Cu(Mg) alloy resistivity)

  • 조흥렬;조범석;이재갑;박원욱;이은구
    • 한국표면공학회지
    • /
    • 제32권6호
    • /
    • pp.695-702
    • /
    • 1999
  • We have explored the factors affecting the resistivity of Cu (Mg) alloy, which was prepared by sputtering. The results show that the resistivity is a function of Mg content, annealing temperature, annealing time, and Cu-alloy thickness. Addition of Mg to copper increases the resistivity through solute scattering. In addition, increasing Mg content promotes the interfacial reaction between Mg and SiO$_2$ to produce the free silicon and the generated free silicon dissolves into copper, resulting in a significant increase of resistivity. Furthermore, increasing oxidation temperature rapidly decreases the resistivity at the initial stage of oxidation and then continues to increase the resistivity to the saturation value with increasing oxidation time. The saturation value depends on the residual Mg content and the thickness of the alloy. TEM and AES analyses reveal that dense, uniform MgO grows to the limiting thickness of about $150\AA$. However, interfacial MgO does not show the limiting thickness, instead continues to grow until Mg is completely exhausted. From these facts, we proposed the maximum available Mg content needed to from the dense MgO on the surface and suppress the excessive interfacial reaction.

  • PDF