• Title/Summary/Keyword: Surface marker method

Search Result 80, Processing Time 0.031 seconds

Relationship between Center of Pressure and Local Stability of the Lower Joints during Walking in the Elderly Women

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • Objective: The purpose of this study was to determine the relationship between center of pressure (CoP) and local stability of the lower joints, which was calculated based on approximate entropy (ApEn) during walking in elderly women. Method: Eighteen elderly women were recruited (age: $66.4{\pm}1.2yrs$; mass: $55.4{\pm}8.3kg$; height: $1.56{\pm}0.04m$) for this study. Before collecting data, reflective marker triads composed of 3 non-collinear spheres were attached to the lateral surface of the thigh and shank near the mid-segment to measure motion of the thigh and shank segments. To measure foot motion, reflective markers were placed on the shoe at the heel, head of the fifth metatarsal, and lateral malleolus, and were also placed on the right anterior-superior iliac spine, left anterior-superior iliac spine, and sacrum to observe pelvic motion. During treadmill walking, kinematic data were recorded using 6 infrared cameras (Oqus 300, Qualisys, Sweden) with a 100 Hz sampling frequency and kinetic data were collected from a treadmill (Instrumented Treadmill, Bertec, USA) for 20 strides. From kinematic data, 3D angles of the lower extremity's joint were calculated using Cardan technique and then ApEn were computed for their angles to evaluate local stability. Range of CoP was determined from the kinetic data. Pearson product-moment and Spearman rank correlation coefficient were applied to find relationship between CoP and ApEn. The level of significance was determined at p<.05. Results: There was a negative linear correlation between CoP and ApEn of hip joint adduction-abduction motion (p<.05), but ApEn of other joint motion did not affect the CoP. Conclusion: It was conjectured that ApEn, local stability index, for adduction/abduction of the hip joint during walking could be useful as a fall predictor.

Muscle Function Path Analysis through Muscle Activity Analysis of Human Myofascial Meridians

  • Park, Young Hyun;Hong, Aa Reum;So, Jea Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.279-285
    • /
    • 2017
  • Objective: The purpose of this study was to perform a muscle function path analysis of muscle function on myofascial meridians. Method: Seven male students (mean age: $22{\pm}3.46years$; mean mass: $72.71{\pm}8.19kg$; mean height: $174{\pm}4.39cm$) without a history of musculoskeletal system symptoms or injuries were recruited for this study. The measurement muscle of the myofascial line was selected along with the muscle presented in "anatomy trains (Thomas W. Myers. 2014)", and the attachment of the surface EMG (Telemyo 2400T G2, USA) pad was determined according to "EMG analysis (Kim Tae Wan et al., 2013)". The subjects underwent maximum volumetric contraction of their fascia line end muscles three times in lying and standing postures and were subjected to the maximum number of contractions of the myofascial line muscle three times in the lying and standing postures. The sampling rate of the EMG signal was set to 1,000 Hz, and the bandwidth was 20 to 350 Hz. The activity of each muscle was quantitated using the Pearson correlation coefficient, and SPSS 22.0 was used for data analysis. Results: In myofascial meridians, a positive correlation in the myofascial connection and a negative correlation in the mechanical connection were observed. Conclusion: Muscles that show significant contract correlations with one another may be expected to be used as an effective clinical marker in muscle strengthening or relaxation therapy, and rehabilitative training. In this study, the correlation of total myofascial meridians may differ without consideration of functional posture. Future studies need to consider these points.

Human Lung Cancer Cell Xenografts Implanted under the Capsule of Kidney, Spleen and Liver (폐암 세포주를 사용한 신, 비장 및 간 피막하 분식법의 비교)

  • 김수현;김종인;이해영;조봉균;박성달;김송명
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.711-720
    • /
    • 2003
  • Bakground : Complete resection by the surgery has been selected as the treatment of choice in lung cancer patients, but in cases of recurrence after excision or inoperable cases, the importance of anticancer chemotherapy has been emphasized. If one can select a set of the sensitive chemotherapeutic agents before anticancer chemotherapy, it will give more favourable results. Subrenal capsular assay has been recognized as a useful in-vivo chemosensitivity test of thoracic and abdominal tumors and it can be done in a short time for a rapid interpretation of tumor responsiveness to anticancer chemotherapeutic drugs. It has been reported that various kinds of cancer cells can be implantable to the kidney, but so far there is no comparative study of xenogeneic cell implantation on liver, spleen and kidney. The author implanted the human lung cancer cells under the capsule of S.D rat's liver, spleen and kidney respectively and compared the pattern of growth and histology. Material and Method: After incubation of human lung cancer cell line (SW-900 G IV) in RPMI 1640 (Leibovitz L-15 medium) culture media, 3${\times}$3${\times}$3 mm size fibrin clots which contain 108 cancer cells were made. Thereafter the fibrin clots were implanted at subcapsule area of liver, spleen and kidney of S.D. female rat. For immune suppression, cyclosporin-A (80 mg/Kg) was injected subcutaneously daily from post-implantation first day to sixth day. The body weight was measured at pre and post implantation periods. The growth pattern and the size of tumor mass were observed and the pathologic examination and serum tumor marker tests were performed. Result: Body weight increased in both of control and experimental groups. Serum Cyfra 21-1 was not detected. Serum levels of CEA and NSE revealed no significant change. The SCC-Ag increased significantly in implanted group. The growth rate of human lung cancer cells which was implanted on spleen was higher than on liver or kidney. The surface area, thickness, and volume of tumor mass were predominant at spleen. The success rates of implantation were 80% on kidney, 76.7% on spleen and 43.3% on liver. Pathologic examination of implanted tumors showed characteristic findings according to different organs. Tumors that were implanted on kidney grew in a round shape, small and regular pattern. In the spleen, tumors grew well and microscopic neovascularization and tumor thrombi were also found, but the growth pattern was irregular representing frequent daughter mass. Human lung cancer cells that were implanted in the liver, invaded to the liver parenchyme, and had low success rate of implantation. Microscopically, coagulation necrosis and myxoid fibrous lesion were observed. Conclusion: The success rate of implantation was highest in the kidney. And the mass revealed regular growth that could be measured easily. The SCC-Ag was presented earlier than CEA or Cyfra21-1. The Cyfra21-1 was not detected at early time after implantation. The best model for tumor implantation experiment for chemosensitivity test was subrenal capsular analysis than liver and spleen and the useful serum tumor marker in early period of implantation was the SCC-Ag.

Augmented Plasticity: Giving Morphological Editability to Physical Objects (증강가소성: 물리적 오브젝트에 형태적 편집가능성 부여하기)

  • Lee, Woo-Hun;Kang, Hye-Kyoung
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.225-234
    • /
    • 2006
  • Product designers sketch various ideas of foreground figures(detail design) onto background figures(basic form) and evaluate numerous combinations of them in the late stages of design process. Designers have to test their ideas elaborately with a high-fidelity physical model that looks like a real product. However, due to the requirements of time and expense in making high-fidelity design models, it is impossible to evaluate such a number of combinatorial solutions of background and foreground figures. Contrary to digital models, physical design models are not easily modifiable and so designers cannot easily develope ideas through iterative design-evaluation process. To address these problems, we proposed a new concept 'Augmented Plasticity' that gives morphological editability to a rigid physical object using Augmented Reality technology and implemented the idea as Digital Skin system. Digital Skin system figures out the position and orientation of object surface with ARToolKit visual marker and superimposes a deformed surface image seamlessly using differential rendering method. We tried to apply Digital Skin system to detail design, redesign of product, and material exploration task. In consequence, it was found that Digital Skin system has potential to allow designers to implement and test their ideas very efficiently in the late stages of design process.

  • PDF

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

Immunological Synergistic Effects of Combined Treatment with Herbal Preparation (HemoHIM) and Red Ginseng Extracts (마우스세포를 이용한 홍삼추출물과 생약복합추출물의 병용 처리에 따른 면역활성 효과)

  • Byun, Myung-Woo;Byun, Eui-Hong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.2
    • /
    • pp.182-190
    • /
    • 2015
  • This present study demonstrates the immunological synergistic effects of herbal preparation (HemoHIM) and red ginseng powder granule in various immune cell models (bone marrow-derived macrophages, dendritic cells, and mouse splenocytes) from mice. Both herbal preparation and red ginseng extracts were treated to bone-marrow derived macrophages, dendritic cells, and mouse splenocytes, and there was no cytotoxicity at a dose below $200{\mu}g/mL$. Cell proliferation and cytokine [tumor necrosis factor (TNF)-${\alpha}$, interleukin (IL)-6, and IL-12] production tested in bone marrow-derived macrophages and dendritic cells significantly increased upon combined treatment. Cell surface marker (CD 80/86, MHC class I/II)-mediated immune cell activation was highly elevated by combined treatment. For cytokine production in splenocytes, combined treatment significantly increased production of Th 1 type cytokines [IL-2 and interferon (IFN)-${\gamma}$] but not Th 2 type cytokines (IL-4 and IL-10). Therefore, combined treatment with HemoHIM and red ginseng extracts is an effective method to establish powerful immunological synergy in immune cells.

Antitumor Responses of Adoptively-Transferred Tumor-Specific T-Cell Cultures in a Murine Lymphoma Model

  • Kim, Hee-Sue;Lee, Hee-Gu;Lim, Jong-Seok;Lee, Ki-Young;Kim, Jae-Wha;Chung, Kyeong-Soo;Choe, Yong-Kyung;Choe, In-Seong;Chung, Tai-Wha;Kim, Kil-Hyoun
    • BMB Reports
    • /
    • v.28 no.6
    • /
    • pp.556-561
    • /
    • 1995
  • The purpose of this study was to establish an in vitro culture method of tumor-specific T cells, and determine the efficacy of the cultured tumor-specific cytotoxic T-lymphocytes (CTL) as an agent of anti-tumor immunotherapy against a murine lymphoma, TIMI.4. Tumor-specific T-lymphocytes derived from C57BL/6 mice (thy-1.2) immune to TIMI.4 were activated by in vitro stimulation with the irradiated TIMI.4 cells, and expanded by restimulation with TIMI.4 in the presence of the concanavalin A-stimulated rat spleen culture supernatant, and splenic antigen-presenting cells. In vitro restimulation enhanced markedly the proportion of $CD8^+$, a predominant surface marker of CTL and the cytotoxic activity in the cultured immune T cell population. The resulting TIMI.4-specific T cells were adoptively transferred into nude mice. The tumor cells residing in the host after 7 days of adoptive transfer to B6.PL (thy-1.1) mice were quantified by use of an antibody directed to the thy-1.2 allele. The TIMI.4 cells in the recipient nude mice were decreased in a dose-dependent manner. Anti-tumor activity of the TIMI.4-specific T cells was also demonstrated by a survival test, where the tumor-bearing nu/nu mice which received the activated T-cells survived about 30% longer than the control mice which received the tumor cells alone. These suggest that adoptive transfer of TIMI.4-specific T cells could be a candidate for effective therapy of the murine lymphoma.

  • PDF

Surface Marker Analysis in Acute Leukemias (백혈병의 면역학적 표지자검사의 결과분석)

  • Moon, Jin-Young;Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.2
    • /
    • pp.359-369
    • /
    • 1997
  • We studied the expression of the cell surface antigen associated with myeloid and lymphoid leukemias on bone marrow or peripheral blood blast cells from 153 leukemic patients including 61 cases of acute myelogenous leukemias(AML), 46 of acute lymphocytic leukemias(ALL) and 12 of acute leukemias. They were analyzed by direct or indirect immunofluorescence method for reactivity with the monoclonal antibodies to B cells(CD10, CD19, SmIg), T cells(CD2, CD5, CD7, CD3, CD4, CD8), myeloid antigen(CD13, CD14, CD33, CD61) and a nonspecific antigen, HLA-DR. Lymphoid associated markers detected on AML is CD7 32.8%, CD10 14.8%, CD5 13.1%, CD2 6.6% and CD19 1.6%. TdT was positive in 4.9% of AMLs. Hybrid leukemias were 8 cases out 61 AML cases and were mainly composed of monocytic lineage, M4 and M5a. Myeloid markers detected in ALL were CD13 2.2% and CD33 2.2%. In this study, immunologically classified ALLs were composed of 65.2% of CALLA (+) B precursor type, 10.9% of CALLA (-) B precursor pattern, 8.7% of T cell type, 2.2% of B cell type, 4.5% of mixed lymphoid lineage(B&T), 2.2% of undifferentiated leukemia, and 6.5% of hybrid leukemia. Twelve cases of acute leukemias ware finally diagnosed to be 5 cases of hybrid leukemia, 3 cases of B lineage, 3 case of T lineage and 1 case of mixed lymphoid(B&T) leukemia. In summary, we think the best method for typing acute leukemias is by using a combination of FAB classification and immunophenotying.

  • PDF

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

A Study on the Expression of CD44s and CD44v6 in Non-Small Cell Lung Carcinomas (비소세포성 폐암종의 CD44s 및 CD44v6의 발현에 대한 연구 -CD44의 발현에 대한 연구-)

  • Chang, Woon-Ha;Oh, Tae-Yun;Kim, Jung-Tae
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.1-11
    • /
    • 2006
  • Background: CD44 is a glycoprotein on the cell surface which is involved in the cell-to-cell and cell-to-matrix interaction. The standard form, CD44s and multiple isoforms are determined by alternative splicing of 10 exons. Recent studies have suggested that CD44 may help invasion and metastasis of various epithelial tumors as well as activation of Iymphocytes and monocytes. The expression pattern of CD44 can be different according to tumor types. The author studied the expression pattern of CD44s and one of its variants, CD44v6 in non-small cell lung carcinomas (NSCLC) to find their implications on clinicopathologic aspects, including the survival of the patients. Material and Method: A total of 89 primary NSCLSs (48 squamous cell carcinomas, 33 adenocarcinomas, and 8 undifferentiated large cell carcinomas) were retrieved during the years between 1985 to 1994. The immunohisto chemistry was done by using monoclonal antibodies and the CD44 expression for angiogenesis was evaluated by counting the number of tumor microvessels. Result: Seventy-one (79.8$\%$) and 64 (71 .9$\%$) among 89 NSCLSs revealed the expression of CD44s and CD44v6, respectively. The expression of CD44s was well correlated with that of CD44v6 (r=0.710, p < 0.0001). The expression of CD44s and CD44v6 was associated with the histopathologic type of the NSCLCs, and squamous cell carcinoma was the type that showed the highest expression of CD44s and CD44v6 (p < 0.0001). Microvessel count was the highest in adenocarcinomas (113.6$\pm$69.7 on 200-fold magnification and 54.8$\pm$41.1 on 400-fold magnification) and correlated with the tumor size of TNM system (r=0.217, p=0.043) and CD44s expression (r=0.218, p=0.040). In adenocarcinoma, the patients with higher CD44s expression survived shorter than those with lower CD44s expression (p=0.0194) but there was no statistical significance on multivariate analysis(p=0.3298). Conclusion: The expression of both CD44s and CD44v6 may be associated with the squamous differentiation in non-small cell lung carcinomas. The relationship of CD44s expression with micro-vessel density of the tumor suggests an involvement of CD44s in tumor angiogenesis, which in turn would help tumor growth.