• Title/Summary/Keyword: Surface luminance

Search Result 185, Processing Time 0.033 seconds

Effect of Luminance Contrast Ratio of Character on Readability and Visual Fatigue during Long-term Reading Using Tablet PC in Low Luminance Environment (저휘도 환경에서 태블릿 PC를 이용한 장시간 독서시 문자대비가 가독성과 피로감에 미치는 영향)

  • Yu, Hanui;Akita, Takeshi
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.191-202
    • /
    • 2019
  • This study examines the effect of luminance contrast ratio of character on readability and visual fatigue during an hour-long reading session while using a tablet PC in ambient environments having low luminance limited to $25cd/m^2$. Experiments were conducted with four patterns of the tablet's luminance contrast ratio of characters, namely 1:2.5, 1:4.5, 1:6.5, and 1:8.5, in low ambient luminance of $9cd/m^2$ and $25cd/m^2$. The obtained results show that the characters can be easily read at the luminance contrast ratio of character of 1:8.5 under surface luminance of $25cd/m^2$. Visual fatigue was evaluated through a subjective survey of symptoms. Physical, psychological, and visual fatigue were observed at a surface luminance of $9cd/m^2$, whereas solely visual fatigue was felt at a surface luminance of $25cd/m^2$. By assessing the physical fatigue using the value, it has been found that smaller the luminance contrast ratio of character, greater is the CFF variation rate. Furthermore, readability is poor and visual fatigue can be observed when the surface luminance is lower than the ambient luminance. However, readability can be improved by increasing the luminance contrast ratio of character to a value of 1:8.5. Thus, in low luminance environments, luminance contrast ratio of characters can affect readability and fatigue. Consider providing the full form of "CFF" so that the acronym can be used unambiguously throughout the manuscript.

Development of the Program Road lighting Road Surface Property Measuring Apparatus (도로조명용 프로그램과 노면특성 장치의 개발)

  • ;金紀勳
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.133-133
    • /
    • 1999
  • Average illuminance and luminance can be calculated by graphical methods to a certain extent but to calculate for a wide place a suitable software is needed. Softwares suitable for this purpose have been already developed in foreign nations, but the appropriate softwares for domestic use have not been developed. Therefore a program is developed which is executable in Hangul Windows. The softwares LAPRoad, is developed to calculate luminance and illuminance distribution of road surface, as well as average luminance and illuminance, overall uniformity, longitudinal uniformity, threshold increment veilling luminance and glare. And an apparatus that measures road surface reflection properties is developed. Because the road surface reflection properties is very important in luminance calculation, then concrete road surface reflection properties were measured.

A Study on Luminance Contrast Criteria for Tactile Walking Surface Indicators (시각장애인 점자블록의 휘도대비 기준에 대한 연구)

  • Shin, Dong-Hong;Park, Kwang-Jae;Kim, Sang-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.1
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are the number of color tactile walking surface indicators installed in Korea, because of indefinite regulation in blind and vision-impaired persons' tactile walking surface indicators. In case of yellow tactile walking surface indicators, it shows a deviation severe color. In this study, the researchers suggested color and brightness reference for helping blind and vision-impaired persons' walking through analyzing the color references of tactile walking surface indicators and the color luminance between tactile walking surface indicators and sidewalk currently used. Method: Reasonable luminance contrast criteria is suggested by examining ways of improving the recognition and recognition of objects according to color contrast visually impaired through literature review and analyzing standards of tactile walking surface indicators and the Europe, Japan and Australia of color and luminance contrast criteria. And by examining the color of the tactile walking surface indicators reported in Korea currently used to derive the problem presented by the luminance contrast in the reference and comparison. Finally, the visually impaired tactile walking surface indicators is set for color selection criteria for the recognition rate improves. Results: In order to improve the recognition rate to be tactile walking surface indicators of the contrast of the visually impaired and the environment than the color of the tactile walking surface indicators itself to secure always a certain level or more of brightness contrast values in the set of the color of the tactile walking surface indicators so important. Implication: In order to set the blind tactile walking surface indicators color recognition based on the verification of the real pedestrian based on the results presented in this paper it is required. It is to be understood as an element of the barrier free configuration for securing the walking pedestrian safety.

Appropriateness Assessment of Illuminance-Based Evaluation Method in Automotive Headlight Visibility Performance (조도 기반 자동차 전조등 시인 성능 평가 방법의 적정성 평가)

  • Cho, Wonbum
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.165-173
    • /
    • 2017
  • PURPOSES : The current practice in car headlight visibility performance evaluation is based on the luminous intensity and illuminance of headlight. Such practice can be inappropriate from a visibility point of view where visibility indicates abilities to perceive an object ahead on the road. This study aimed at evaluating the appropriateness of current headlight evaluation method. METHODS : This study measured the luminance of object and road surface at unlit roadways. The variables were measured by vehicle type and by headlight lamp type. Based on the measurements, the distance where drivers can perceive an object ahead was calculated and then compared against such distance obtained by conventional visibility performance evaluation. RESULTS : The evaluation method based on illuminance of headlight is not appropriate when viewed from the visibility concept that is based on object-perceivable distance. Further, the results indicated a shorter object-perceiving distance even when road surface luminance is higher, thereby suggesting that illuminance of headlight and luminance of road surface are not the representative indices of nighttime visibility. CONCLUSIONS : Considering that this study utilized limited vehicle types and that road surface (background) luminance can vary depending on the characteristics of the given road surface, it would likely go too far to argue that this study's visibility performance evaluation results can get generalized to other conditions. Regardless, there is little doubt that the current performance evaluation criterion which is based on illuminance, is unreasonable. There should be future endeavors on the current subject which will need to explore study conditions further, under which more experiments should be conducted and effective methodologies developed for evaluating automotive headlight visibility performance. Needs are recognized particularly in the development of headlight visibility performance evaluation methodology which will take into account road surface (background) luminance and luminance contrast from various perspectives as the former indicates the driver's perception of the front road alignment and the latter being indicative of object perception performance.

Perception of Glare Source According to the Luminance Difference on a Window Plane (창면의 상하부 휘도차에 따른 글레어 광원의 인식변화)

  • Kim, Wonwoo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.17-22
    • /
    • 2007
  • The existing discomfort glare models are based on research that was conducted exclusively with uniform luminance sources. It is impossible to apply the models to windows of non-uniform luminance. For evaluating discomfort glare from windows, the method selecting glare source on a window plane is necessary. This study was carried outto propose a practical method to choose glare source from anon-uniform window plane. In the experiment, the perception of glare source according to the luminance difference is examined using a simulated windowof non-uniform luminance. The surface of the window is divided into two or three parts, and different luminance is setting on each surface. The observers were asked to decide whether the lower part of the window can be perceived as a glare source or not. The result shows that the lower part is perceived as a glare source when the lower part has over 37% of the luminance of the upper part of the window divided into two parts, and when it has over 51% of the luminance of the upper part of the window divided into three parts. the results may be applicable to select the glare source in awindow.

The Study on the Analysis of Road Surface Brightness of Low Mounted Road Lighting System (낮은 도로 조명의 노면 휘도 실태 분석에 대한 연구)

  • Kiho Nam;Chung Hyeok Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.314-321
    • /
    • 2024
  • Low road lighting is a lighting device that complements the shortcomings of existing pillar-type street lights. It is a lighting device that emits light from the side of the road surface and adjusts the luminance of the road surface like a light carpet. In this paper, to achieve full commercialization, we analyzed the luminance of the installed road surface and studied whether lighting could replace existing road lighting. In this study, the LMK (Luminance Measurement Camera) LABSOFT program was used to measure and analyze the surface luminance of road lighting, and the RELUX program was used to evaluate and analyze the simulation performance to determine light-based lighting conditions. A study was conducted to determine whether replacing pillar-type road lighting with low-level road lighting in a real environment would ensure comfortable and safe night vision for drivers at night.

Relation of Luminance by Insulator and Phosphor Layer with Thin Type (형광층 및 절연층의 두께에 의한 휘도특성)

  • 박수길;조성렬;손원근;박대희;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.85-88
    • /
    • 1998
  • Light-emitting diode(LEDs), diode arrays, and phosphor display panels are finding increased use in a variety of commercial applications. Present and anticipated application of these devices include solid state indicator(e.g., digital clocks, meter readout) and display systems(e.g., instrument panels, TV display), the application being determined by the light -output capability and size availability(cost) of the particular device. In this work, Phosphor based on ZnS:Cu are used. Relation by luminance with the thickness of insulating layer and phosphor layer are discussed. Increased thickness of insulating layer are stable on voltage to 300V. By considering thickness and voltage, optimal structure and thickness are investigated. Also in order to maximize even surface emission, various sieving process are introduced. Very similar phosphor particle size is selected. Luminance by various wave intensity is also investigated. 150cd/m$^2$ luminance are investigated in stable voltage and frequency.

  • PDF

Design of 30Watt Inverter for high luminance LCD Backlight Application (LCD용 고휘도 Backlight 구동을 위한 30Watt급 인버터의 설계)

  • 허정욱;김태조;임성규
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.747-750
    • /
    • 1999
  • A 30Watt inverter with 300: 1 dimming capability for high luminance, one cell, surface discharge plasma light source for LCD backlight was designed and tested. It was possible to achieve 300:1 dimming control by using the push-pull type inverter with burst-mode dimming control. The surface discharge plasma light cell with luminance of more than 5, 260 cd/$m^2$ was successfully operated.

  • PDF

Luminance Assessment of Outdoor Lighting for Advertisements at Night (옥외광고용 발광조명의 야간휘도분포 분석)

  • Shin, Hwa Young;Lee, Jong Soo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

Analysis of Luminance distribution of Illuminated Bridges by View (조망의 변화에 따른 교량경관조명의 휘도특성분석)

  • Choi, Yoon-Seok;Jeong, In-Young;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.1-8
    • /
    • 2006
  • The study is to analyze the surface luminance of the illuminated bridges according to the change of view point using luminance measurements with instrument CS-100 and ProMetric 1400. For the purpose the illuminated bridges of the structure type were sleceted. Also, the view points were classified the three types which are a perspective view, a building view, a driver view. The luminance of the surrounding sky, surface of river, upper structure or bridge, girder side, and pier or the objects was measured. As a result of this study, The Kwangjin and Dongho Bridge showed the luminance distribution of a perspective view was high. And the Olympic and Dongjac bridge the luminance distribution of building view was high. The luminance effect of the girder bridge that has no upper structure was distinguished for the perspective view, and the cable-stayed girder bridge and the arch bridge were characterized as the building view.