• 제목/요약/키워드: Surface leakage

검색결과 776건 처리시간 0.031초

Leakage Flux Distribution in the Simulated Environment

  • Kim, Chung-Hyeok;Kim, Tag-Yong;Oh, Yong-Cheul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.401-405
    • /
    • 2012
  • Current research about voltage leakage involves investigation of the effects of leaked voltage and current on humans through simulated environments and dummies. Electrocution results from leaked current when electricity flows through the body as a result of potential difference. Research that analyzes actual electrocution is insufficient because of the danger from leaked voltage present in the leakage area. This thesis analyzes magnetic flux density from current around a leak to investigate the distribution of current. The authors used a simulated environment to investigate electrocution accidents that frequently occur during floods through leakage along metal surfaces, and evaluated the distribution of leaked magnetic flux.

누설전류 측정을 통한 옥외절연물 오손도 측정 (Study for Measurement of Polluted Outdoor Insulations Using Leakage Current)

  • 이부원;김성중;박우용;김영달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2068-2069
    • /
    • 2007
  • This study describes a compairison leakage current properties between a polluted insulator and insulator subjected to salt polluted condition. Exposure tests at a sea coast test and the leakage current of insulators, climate conditions, and salt deposit density were measured during the tests. Appearance of leakage current for the insulator was affected by the humidity and the salt deposition on the surface. comparison of leakage current under salt polluted conditions. salt polluted test and humidity tests were carried out in laboratory using the same insulator profiles in oder to determine the leakage current patterns during critical conditions

  • PDF

Reduction of Leakage current Generated by Degradation in Organic Thin Film Transistors using Pattern on Pentacene Surface by Atomic Force Microscope

  • Hwang, Hyun-Doo;Kim, Hyun-Suck;Kim, Chang-Ho;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.560-562
    • /
    • 2009
  • In this paper, we proposed a simple method of decreasing the off current generated by degradation for improve the electrical characteristics such as mobility and on/off current ratio by making the line patterns on the pentacene surface between the electrodes using atomic force microscope (AFM) lithography.

  • PDF

Surface Texturing에 의한 유압부품의 마찰저감 (Surface Texturing in Hydraulic Machine Components for Friction Reduction)

  • 박태조;김민규
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권1호
    • /
    • pp.27-33
    • /
    • 2016
  • In hydraulic machinery, the hydraulic fluid acts primarily as working fluid and secondarily as a lubricant. Hence, the viscous friction force acting on the sliding components should be reduced to improve the mechanical efficiency. It is now well known that the surface texturing is a useful method for friction reduction. In this study, using a commercial computational fluid dynamics (CFD) code, FLUENT, the lubrication characteristics of a surface textured slider bearing under high boundary pressure difference is studied. The streamlines, velocity profiles, pressure distributions, load capacity, friction force and leakage flowrate are highly affected by the film thickness ratio and the textured region. Partial texturing at the inlet region of the inclined slider bearing can reduce both friction force and leakage flowrate than in the untextured case. The present results can be used to improve the lubrication characteristics of hydraulic machinery.

가정용 연료전지 시스템 내부 수소 누출의 비정상 및 정상 상태에 관한 전산 해석 (A CFD Study on Unsteady and Steady State of the Hydrogen Leakage for Residential Fuel Cell System)

  • 정태용;안재욱;남진현;신동훈;김영규
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.41-46
    • /
    • 2007
  • 본 연구는 국내 F사의 가정용 연료전지 시스템의 실제 크기를 모델로 하여, 시스템 내부에 4가지 구성품(개질기, 연료전지 스택, 가습기, 탈황기)이 시스템 체적 중 약 30%를 차지하고 있을 때, 환기 면적과 수소 누출량을 변화시키면서 전산 해석을 수행하였다. 환기 면적 1%, 수소 누출량 1%인 경우, 비정상 상태 전산 해석 결과, 수소는 약 50초 후 누출 지점 근처에서 농도 변화를 확연히 감지할 수 있었으며, 200초 후, 시스템 하부에 비해 상부에서 농도 증가를 뚜렷하게 알 수 있었다. 환기 면적 1%, 수소 누출량 1%, 3%, 5%의 대한 정상 상태 해석 결과, 수소 누출량이 5%가 되면 시스템 전 영역에서 수소의 인화 하한(4%, 체적기준)에 도달하는 것을 확인하였다. 환기 면적 2%, 수소 누출량 1%인 경우, 비정상 상태 전산해석 결과, 수소는 약 60초 동안은 누출 지점에서 하부측으로 농도 증가를 보이다가, 점차 상부측 환기구를 통해 배출되어 약 250초가 지난 후 정상 상태에 도달하였다. 환기 면적 2%, 수소 누출량 1%, 3%, 5%의 정상 상태 해석 결과, 수소 누출량이 5%가 되더라도 대부분의 영역에서 경보 농도 수준(1%, 체적기준) 이하임을 확인할 수 있었으나, 누출 지점으로부터 상부쪽으로 위험 영역이 존재함을 알 수 있었다.

  • PDF

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;이운용;한동희;강성화;최인혁;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

환형 캐스케이드 내 고정된 터빈 블레이드 및 슈라우드에서의 열/물질전달 특성 (I) - 블레이드 끝단 인접 표면 - (Heat/Mass Transfer Characteristics on Stationary Turbine Blade and Shroud in a Low Speed Annular Cascade (I) - Near-tip Blade Surface -)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제29권4호
    • /
    • pp.485-494
    • /
    • 2005
  • For the extensive investigation of local heat/mass transfer on the near-tip surface of turbine blade, experiments were conducted in a low speed stationary annular cascade. The turbine test section has a single stage composed of sixteen guide vanes and blades. The chord length and the height of the tested blade are 150 mm and about 125 mm, respectively. The blade has flat tip geometry and the mean tip clearance is about $2.5{\%}$ of the blade chord. Detailed mass transfer coefficient on the blade near-tip surface was obtained using a naphthalene sublimation technique. The inlet flow Reynolds number based on chord length and incoming flow velocity is changed from $1.0{\times}10^{5}\;to\;2.3{\times}10^{5}.$ Extremely complex heat transfer characteristics are observed on the blade surface due, to complicated flow patterns, such as flow acceleration, laminarization, transition, separation bubble and tip leakage flow. Especially, the suction side surface of the blade has higher heat/mass transfer coefficients and more complex distribution than the pressure side surface, which is related to the leakage flow. For all the tested Reynolds numbers, the heat/mass transfer characteristics on the turbine blade are the similar. The overall averaged $Sh_{c}$ values are proportional to $Re_{c}^{0.5}$ on the stagnation region and the laminar flow region such as the pressure side surface. However, since the flow is fully turbulent in the near-tip region, the heat/mass transfer coefficients are proportional to $Re_{c}^{0.8}.$

제주도 공공 농업용 지하수의 효율적 누수량 산정 연구 (Efficient Leakage Estimation of Public Agriculture Groundwater in Jeju Island)

  • 김민철;박원배;강봉래;김지명
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권3호
    • /
    • pp.1-11
    • /
    • 2020
  • In this study, leakage ratios of Jeju Island's public agricultural groundwater were calculated by utilizing field measurements of groundwater level and surface reservoir water level. The average leakage ratios were 75.6% at groundwater well A and 57.5% at well B, with the ratio inversely proportional to agricultural water usage. The level of agricultural reservoirs varied at constant intervals at night, and the amount of water leakage associated with the variation was estimated as 0.1 - 16.3 ㎥/h. The leakage ratio was also influenced by pipeline length, average slope, and number of farmhouses. Currently, the estimation of agricultural water leakage on Jeju Island is based upon field inspection which is very labor- and cost intensive. The leakage ratio estimated by monitoring the reservoirs associated with the well A and B were 73.3 and 54.7%, respectively, consistent with the values obtained by field measurements.

위생매립지 누출검지 및 누출위치 파악을 위한 전극배치시스템 개발 (Development of new electrical leakage detection system for waste landfil)

  • 한상재;신현영;정재현;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.242-250
    • /
    • 2008
  • Lining systems are used for two purpose in landfills : as covers to minimize leachate generation and surface water contamination by providing a barrier from precipitation and other percolating waters, and as containment liners to contain leachate and minimize its downward migration into underlying groundwater. So identifying leaks in landfill liners is an essential part of waste management. There are many leakage detection systems to monitor and seek leakage location, such as two electrode method, electrode grid method, diffusion hoses, capacitance sensors and tracers sensing cables. However, most of them can be applied in the new landfill construction sites because sensors must be installed prior to work. This paper presents a new type of leakage detection system, so called fence type electrode arrangement system, to monitor leakage and to seek leakage location in working landfill as well as new landfill. This system is based on the measurement of an electrical current flowing through leakage point. Series of laboratory tests are performed to investigate an availability of this system and this paper present some of these results.

  • PDF

Fractal Analysis of the Surface in Thin Film Capacitors

  • Hong, Kyung-Jin;Min, Yong-Ki;Cho, Jae-Cheol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권2호
    • /
    • pp.18-22
    • /
    • 2001
  • The thin films of high permitivity in ferroelectric materials using a capacitor are applied to DRAMs and FRAMs. (Ba, Sr)TiO$_3$ thin as ferroelectric materials were prepared by the sol-gel method and made by spin-coating on the Pt/Sio$_2$/Si substrate at 4,000 [rpm] for 10 seconds. The structural characteristics of the surface were analyzed by fractal dimension. The thickness of BST ceramics thin films was about 260∼280 [nm]. The property of the leakage current was stable with 10-9∼10-11[A] when the applied voltage was 0∼3[V]. BST thin films ha low leakage current properties when fractal dimension was low and a coating area was high.