• 제목/요약/키워드: Surface discharge

검색결과 2,014건 처리시간 0.031초

Estimation of River discharge using Very High-Resolution Satellite Data in Yangtze River

  • Zhang, Jiqun;Xu, Kaiqin;Watanabe, Masataka;Sun, Chunpeng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.728-733
    • /
    • 2002
  • The measurement of river discharge is among the most fundamental observations and is necessary for understanding many water-related issues, such as flooding hazards, sediment transportation, and nutrient movement. Traditionally river discharge is estimated by measuring the water stage and converting the measurement to discharge using a stage-discharge rating curve. The possibility of monitoring river discharge from satellites has been largely ignored, because it is difficult to measure water surface information from space with sufficient precision. In this paper, an efficient approach to discharge estimation using mainly satellite data is developed and described. The proposed method, which focuses on the measurement of water-surface width coupled with river width-stage and stage-discharge relationships, is applied to the Yangtze River with good results.

  • PDF

경사지 밭에서 발생하는 토양유실 저감을 위한 피복재 적용 (Surface Cover Application for Reduction of Runoff and Sediment Discharge from Sloping Fields)

  • 신민환;원철희;박운지;최용훈;신재영;임경재;최중대
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.129-136
    • /
    • 2011
  • To measure effects of surface cover on runoff and sediment discharge reduction using rainfall simulator, four(5 m${\times}$30 m scale) plot experiments were conducted in this study. Surface covers made with straw mat, Polyacrylamide (PAM), chaff, and sawdust were simulated 4 times under 31.1~44.4 mm/hr rainfall intensities. Compared with results from control plot, the time of runoff generation is delayed and outflow volume decreased with surface cover. Effects on runoff reduction of straw mat, PAM, sawdust and chaff ranged 4.7~81.5 % and runoff rate reduced by 6.5~76.1 % respectively, when compared with those from control plot. The percentage of decrease in sediment discharge were 99.7~99.8 % from straw mat+sawdust+PAM plots, 85.9~95.6 % from straw mat+PAM plots, and 98.5~99.4 % from straw mat+chaff+PAM plots. The runoff, sediment discharge, and SS concentration reduction efficiencies of the cover materials were outstanding when compared to control plot. It was analyzed that reduction of runoff and sediment discharge were mainly contributed by decrease in rainfall energy impact and flow velocity and increase of infiltration due to the surface cover materials. The results could be used as a base for the development of best management practices (BMPs) to reduce runoff, sediment discharge from sloping field.

수면경사를 반영한 하천 유량산정에 관한 연구 (A Study on Development of Estimation for Discharge Rate Reflecting Water Surface Slope)

  • 추태호;홍순헌;박상진;김영환
    • 한국콘텐츠학회논문지
    • /
    • 제17권2호
    • /
    • pp.535-542
    • /
    • 2017
  • 우리나라는 갈수기와 홍수기의 유량차이가 극심하여 수자원 관리에 대한 중요성이 대두되고 있는 실정이다. 하천의 특성을 파악하기 위해 정확한 유량을 산정해야 한다. 유량을 산정하기 위해서는 유량을 구하고자 하는 하도의 단면적을 산정하고, 해당 단면에서의 유속을 측정해 연속방정식을 이용하여 유량을 산출해야 한다. 보편적으로 수위-유량관계식으로부터 유량을 산정하지만, 이 경우에는 동일한 수심 동일한 유량만을 산출할 수밖에 없다는 단점이 있다. 그래서 본 연구에서는 낙동강 교량 강창교 지점의 성서관측소의 수심과 ADVM를 이용하여 측정된 수심을 이용한 수면경사와 ADVM지점의 수심을 이용하여 유량산정식을 개발하였다. 자연하천의 흐름은 정류나 등류가 아닌 부정류 흐름이기 때문에 하상경사가 아닌 수면경사를 반영하고자 본 연구에서는 두 지점의 측정된 수심으로부터 손쉽게 유량을 산정하는 방법을 제안하였다.

전지구 고해상도 수문모델 적용을 위한 격자유량 추정 방법 적용 연구 (Application of a Method Estimating Grid Runoff for a Global High-Resolution Hydrodynamic Model)

  • 류영;지희숙;황승언;이조한
    • 대기
    • /
    • 제30권2호
    • /
    • pp.155-167
    • /
    • 2020
  • In order to produce more detailed and accurate information of river discharge and freshwater discharge, global high-resolution hydrodynamic model (CaMa-Flood) is applied to an operational land surface model of global seasonal forecast system. In addition, bias correction to grid runoff for the hydrodynamic model is attempted. CaMa-Flood is a river routing model that distributes runoff forcing from a land surface model to oceans or inland seas along continentalscale rivers, which can represent flood stage and river discharge explicitly. The runoff data generated by the land surface model are bias-corrected by using composite runoff data from UNH-GRDC. The impact of bias-correction on the runoff, which is spatially resolved on 0.5° grid, has been evaluated for 1991~2010. It is shown that bias-correction increases runoff by 30% on average over all continents, which is closer to UNH-GRDC. Two experiments with coupled CaMa-Flood are carried out to produce river discharge: one using this bias correction and the other not using. It is found that the experiment adapting bias correction exhibits significant increase of both river discharge over major rivers around the world and continental freshwater discharge into oceans (40% globally), which is closer to GRDC. These preliminary results indicate that the application of CaMa-Flood as well as bias-corrected runoff to the operational global seasonal forecast system is feasible to attain information of surface water cycle from a coupled suite of atmospheric, land surface, and hydrodynamic model.

질소산화물 제거를 위한 무성 방전 공정의 전기 및 NO 전환 특성 (Electrical and NO Conversion Characteristics of Dielectric Barrier Discharge Process)

  • 이용환;정재우;조무현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.15-21
    • /
    • 2002
  • We investigated effects of electrical, physical, and chemical parameters on energy transfer, NO conversion, and light emission in the dielectric barrier discharge (DBD) process. As gap distance between electrodes increased, discharge onset voltage increased. However, as gap distance between electrodes increased, electric field which initiates discharge showed approximately the same value, 30kV/cm. The discharge onset voltage of the coarse surface electrode was lower than that of the smooth surface electrode. And, energy transfer was slightly enhanced in the coarse electrode condition. However, NO conversion rate decreased with the coarse surface electrode because more uniform discharge can be obtained on the smooth surface electrode. The NO conversion rate increased with decreasing the initial concentration, so the DBD process is more feasible in the lower concentration condition. The variation of gas residence time tested at the same energy density in the experiment did not affect on the NO conversion. The result shows that the NO conversion rate mainly depends on the energy density. The DBD process is able to adjust on plasma-photocatalyst process because it emits the short wavelength light in the range of ultraviolet. The intensity of light emission increased with the increase of the energy transfer to the reactor and the gas flow rate.

수질 개선용 방전 리액터의 개발과 기본적 수질 특성 변화 조사 (The development of discharge reactor for water purification and the fundamental study on the change of water characteristics)

  • 한상보;박재윤;김종석;정장근;고희석;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2193-2195
    • /
    • 2005
  • The hybrid discharge reactor was designed for the application of wastewater treatment and the removal of hazardous volatile organic substances in water. This discharge type was similar to the barrier discharge, and the surface discharge on the dielectric surface was propagated to the water surface. That caused the heterogeneous chemical reaction strongly at the interface between the working gases and the water surface. Changes of the conductivity, acidity, and the dissolved ozone with respect to the treatment time and water quantities were studied as the fundamental experiment. The concentration of hydrogen ions largely increased with increasing the treatment time and the conductivity increased with respect to the increase of water quantities under the constant other discharge parameters.

  • PDF

방전에너지에 따라 동전극과 흑연전극이 방전가공면에 미치는 영향 (Influence on EDM Surface with the Copper and Graphite Electrode According to the Discharge Energy)

  • 최재용;전언찬;정재현
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.53-59
    • /
    • 1997
  • This study has been performed to inmvestigate MRR(metal removal rate), REW(relative electrode wear), surface roughness, heat transumutation layer and microhardness distribution in cross-section of the machined surface with various pulse-on duration and peak pulse current, using the copper and graphite electrode on the heat treated STD11 which is extensively used for metallic molding steel with the EDM. The results obtained are as follows; a) There exists critical pulse-on duration(If Ip equals 5A, .tau. on is 50 .mu. s) which shows the the maximum MRR in accordance with peak oulse current and the MRR decreases when the pulse-on duration exceeds the critical pulse-on during because of the abnormal electric discharge. b) Safe discharge is needed to make maximum of MRR and the metalic organization must be complicated for discharge induction. c) Graphite has much more benefits than copper electrode when rapid machining is done without electrode wear. d) The most external surface has the highest microhardness because of car- burizing from heat analysis of the dielectric fluid and the lower layar of the white covered layer has lower microhar dness than base matal because of softening.

  • PDF

무성방전내에서 톨루엔 제거에 미치는 운전변수의 영향 (Effects of Operating Parameters on Toluene Removal in Dielectric Barrier Discharge Process)

  • 정재우;이용환;박경렬
    • 한국대기환경학회지
    • /
    • 제18권3호
    • /
    • pp.173-182
    • /
    • 2002
  • We investigated the effects of operating variables, such as electrical. reactor and gas parameters on toluene removal and discharge property in the dielectric barrier discharge (DBD) process. The toluene removal was initiated with the energy transfer to the reactor by loading of voltages higher than the discharge onset value. The energy transfer and toluene removal increased with the applied voltage. Higher removal rate was observed with smooth surface electrode despite of lower energy transfer compared with the coarse electrode, because more uniform discharge can be obtained on smooth surface state. The decrease of dielectric material thickness enhanced the removal efficiency by increasing the discharge potential. The toluene removal efficiency decreased with the increase of the inlet concentration. The increase of gas retention time enhanced the removal efficiency by the increase of energy density. The oxygen and humidity contents seem to exert significant influences on the toluene removal by dominating the generation of electrons, ions, and radicals which are key factors in the removal mechanism.

형조 방전가공에서 극간 전압과 가공 안정성에 관한 연구 (A Study on the Gap Voltage and Machining Stability in Diesinking Electrical Discharge Machining)

  • 김광열;이상민;이건기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.429-436
    • /
    • 2003
  • The electrical discharge machining(EDM) with Si electrode instead of Gr or Cu electrode. made enormous effects on the surface. machining time, anti-caustic workpiece surface and so on In this paper. we experimented on the inter-role distance during discharge the electrical phenomenon of inter-pole, the distribution of discharge point. the distribution of off load time. etc., using Si electrode Cu electrode and Gr electrode under the same machining condition. As a result of a large quantity generated exclusive powders. the performance of the EDM using Si electrode. compared with EDM using others. is improved. We show that the quantities of those make far pole-gap discharge and discharge scatter under stable machining status possible.