• Title/Summary/Keyword: Surface density

Search Result 5,287, Processing Time 0.034 seconds

Performance analysis of light guide panel implemented with laser-processed inner and surface patterns (레이저 가공된 내부 및 표면패턴을 가지는 도광판 성능 분석)

  • Choi, Young-Hee;Shin, Yong-Jin;Choi, Eun-Seo
    • Laser Solutions
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • We proposed new light guide panel (LGP) fabrication method exploiting laser-processed inner scatterers and surface pattern. The proposed method has achieved LGP performance improvement in both brightness and uniformity. The inner scatterers and surface pattern of grid type were fabricated with a 2nd harmonic Nd:YAG pulse laser engraving system and a $CO_2$ laser scanning system, respectively. In the implementation of LGP, inner scatterers was arranged in accordance with linear or curved pattern with changing density and surface pattern was engraved on the surface of an inner-scatterers embedded LGP. The increase of scatterers' density and the use of surface patterns in both linear and curved pattern provided high luminance and uniformity enhancement. While thecurved pattern incorporated with increased scatterers' density and surface patterns yielded brightness improvement with preserving good uniformity, the linear pattern showed highly localized brightness near the light entrance of the LGP. We can also observe that the uniformity was mainly determined by pattern of inner scatterers, and the brightness was improved by the higher density and the utilization of surface patterns. From the results, the use of laser-processed inner and surface patterns can be a potential alternative for efficient and simple LGP fabrication method.

  • PDF

Comparison of Surface and Core Peptide Fraction from Apo B-100 of Human LDL (Low Density Lipoprotein)

  • Cho, Hyun-Mi;Shin, Seung-Uon;Kim, Tae-Woong
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.2
    • /
    • pp.145-151
    • /
    • 1999
  • Apolipoprotein B-100 (apo B-100) is an important component in plasma low density lipoproteins (LDL). It function as the ligand for the LDL receptor in peripheral cells. The LDLs are removed from the circulation by both high-affinity receptor-mediated and receptor-independant pathways. LDLs are heterogeneous in their lipid content, size and density and certain LDL subspecies increase risk of atherosclerosis due to differences in the conformation of apo B in the particle. In the present study , surface and core peptide fraction of Apo B-100 have been characterized by comparing peptide-mapping and fluorescence spectroscopy. Surface fragments of apo B-100 were generated by digestion of LDL with either trypsin , pronase, or pancreatin elastase. Surface fractions were fractionated on a Sephadex G-50 column. The remaining core fragments were delipidated and redigested with the above enzymes, and the resulting core peptides were compared with surface peptides. Results from peptide-mapping by HPLC showed pronase-digestion was more extensive than trypsin -digestion to remove surface peptide fraction from LDL. Fluorescence spectra showed that core fractions contained higher amount of tryptophan than surface fractions, and it indicated that core fraction wa smore hydrophobic than surface fractions. A comparison of the behavior of the core and surface provided informations about the regions of apo B-100 involved in LDL metabolism and also about the structural features concerning the formation of atherosclerosis.

  • PDF

Surface Functionalization of Carbon Fiber for High-Performance Fibrous Supercapacitor (고성능 섬유형 슈퍼커패시터를 위한 탄소섬유의 표면 기능화)

  • Lee, Young-Geun;An, Geon-Hyoung
    • Korean Journal of Materials Research
    • /
    • v.32 no.2
    • /
    • pp.107-113
    • /
    • 2022
  • Fibrous supercapacitors (FSs), owing to their high power density, good safety characteristic, and high flexibility, have recently been in the spotlight as energy storage devices for wearable electronics. However, despite these advantages, FCs face many challenges related to their active material of carbon fiber (CF). CF has low surface area and poor wettability between electrode and electrolyte, which result in low capacitance and poor long-term stability at high current densities. To overcome these limits, fibrous supercapacitors made using surface-activated CF (FS-SACF) are here suggested; these materials have improved specific surface area and better wettability, obtained by introducing porous structure and oxygen-containing functional groups on the CF surface, respectively, through surface engineering. The FS-SACF shows an improved ion diffusion coefficient and better electrochemical performance, including high specific capacity of 223.6 mF cm-2 at current density of 10 ㎂ cm-2, high-rate performance of 171.2 mF cm-2 at current density of 50.0 ㎂ cm-2, and remarkable, ultrafast cycling stability (96.2 % after 1,000 cycles at current density of 250.0 ㎂ cm-2). The excellent electrochemical performance is definitely due to the effects of surface functionalization on CF, leading to improved specific surface area and superior ion diffusion capability.

A Study on Applicability of Low-Density Surface Film Copper Mesh for Aircraft (저밀도 표면필름 구리망의 비행체 적용 가능성 연구)

  • Hyun, Se-Young;Kim, Yong-Tae;Kim, Sang-Yong;Kim, Bong-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.10
    • /
    • pp.841-847
    • /
    • 2021
  • In this paper, the applicability of the low-density surface film copper mesh for aircraft applications have been analyzed. Recently, low-density surface film copper mesh is developed to reduce weight and cost compared with traditional surface film copper mesh. In order to apply low-density surface film copper mesh to aircraft, it is needed to analyze its electromagnetic effects as well as structural integrity with sandwich panels to prevent pinholes. The structural integrity and electromagnetic characteristics have been analyzed for 2 samples of low-density surface film copper mesh and 1 sample of surface film copper mesh. To review the applicability of the low-density surface film, it is combined with sandwich composite panel to confirm pinhole effects. The low-density surface film has been modeled as a periodic structure and analyzed with 3D electromagnetic simulation tool. The simulation results has been verified through measured electromagnetic transmission results using free space measurements. From the results, it will be possible to use these results for the analysis and the applicability of low-density surface film copper mesh for aircraft.

The Effect of Surface Recombination Current on the Saturation Current in Si Solar Cell (Si 태양전지(太陽電池)의 표면재결합(表面再結合) 전류(電流)가 포화전류(飽和電流)에 미치는 영향(影響))

  • Shin, Kee-Shik;Lee, Ki-Seon;Choi, Byung-Ho
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.12-18
    • /
    • 1988
  • The effect of surface recombination current density on the saturation current density in Si solar cell has been studied. Theoretical model for surface recombination current was set up from emitter transparent model of M.A. Shibib, and saturation current of Si solar cell made by ion implantation method was also measured by digital electrometer. The theoretical surface recombination current density which is the same as saturation surface recombination current density in Shibib model was $10^{-11}[A/cm^2]$ and the measured value was ranged from $8{\times}10^{-10}$ to $2{\times}10^{-9}[A/cm^2]$. Comparing with the ideal p-n junction of Shockley, transparent emitter model shows improved result by $10^2$ order of saturation current density. But there still exists $10^2$ order of difference of saturation current density between theoretical and actual values, which are assumed to be caused by 1) leakage current through solar cell edge, 2) recombination of carriers in the depletion layer, 3) the series resistance effect and 4) the tunneling of carriers between states in the band gap.

  • PDF

Prediction of terminal density through a two-surface plasticity model

  • Won, Jongmuk;Kim, Jongchan;Park, Junghee
    • Geomechanics and Engineering
    • /
    • v.23 no.5
    • /
    • pp.493-502
    • /
    • 2020
  • The prediction of soil response under repetitive mechanical loadings remains challenging in geotechnical engineering applications. Modeling the cyclic soil response requires a robust model validation with an experimental dataset. This study proposes a unique method adopting linearity of model constant with the number of cycles. The model allows the prediction of the terminal density of sediments when subjected to repetitive changes in pore-fluid pressure based on the two-surface plasticity. Model simulations are analyzed in combination with an experimental dataset of sandy sediments when subjected to repetitive changes in pore fluid pressure under constant deviatoric stress conditions. The results show that the modified plastic moduli in the two-surface plasticity model appear to be critical for determining the terminal density. The methodology introduced in this study is expected to contribute to the prediction of the terminal density and the evolution of shear strain at given repetitive loading conditions.

The Influence of Electrolytic Condition on Tunnel Etching and Capacitance Gain of High purity Aluminium Foil on capacitor (전해조건이 고순도 알루미늄 박 콘덴서의 터널에칭과 정전용량에 미치는 영향)

  • 이재운;이병우;김용현;이광학;김흥식
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.1
    • /
    • pp.44-56
    • /
    • 1997
  • Influence of electrochemical etching conditions on capacitance gain of aluminium electrolytic on capacitor foil has been investigated by etching cubic textured high purity aluminum foil in dilute hydrochloric acid. Uniformly distributed etch pit tunnels on aluminum surface have been obtained by pretreatment aluminium foil in 10% NaOH solution for 5 minutes followed by electrochemical etching. Electrostatic capacitance of etched aluminium foil anodized to high voltage increased with the increase of current density, total charge, temperature and concentration of electrolyte up to maximum CV-value and then deceased. Election optical observation of the etched foil revealed that the density of etch of etch pits increased with the increase of current density and concentration of electrolyte. this increase of etch pit density enlarged of the increase of capacitance. However, abnormal high current density and high electrolyte concentration induced the local dissolution of the foil surface which resulted the decrease of foil capacitance.

  • PDF

Surface roughness changes in Al2O3 induced by Nd:YAG laser irradiation

  • Yeo, Sun-Mok;Lee, Seong-Jun;Park, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.331-331
    • /
    • 2011
  • We investigated the surface roughness and surface morphology changes for the laser irradiated alumina plates by a Q-switched Nd:YAG laser. For the laser irradiation on the alumina plates with ${\lambda}$ = 1064 nm, the surface roughness decreases with the increasing energy density. The surface morphology shows that the edges of alumina grains become dull with the increasing energy density. For ${\lambda}$ = 532 nm, increasing scan time at the same energy density causes a rough surface. We discuss the physical reason of the surface roughness and surface morphology changes.

  • PDF

Investigation on Electrolytic Corrosion Characteristics with the Variation of Current Density of 5083-H321 Aluminum Alloy in Seawater (5083-H321 알루미늄 합금의 해수 내 전류밀도의 변화에 따른 전식 특성 연구)

  • Kim, Young-Bok;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.1
    • /
    • pp.23-29
    • /
    • 2019
  • Electrolytic corrosion of the ship's hull can be occurred due to stray current during welding work using shore power and electrical leakage using shore power supply. The electrolytic corrosion characteristics were investigated for Al5083-H321 through potentiodynamic polarization and galvanostatic corrosion test in natural seawater. Experiments of electrolytic corrosion were tested at various current densities ranging from $0.01mA/cm^2$ to $10mA/cm^2$ for 30 minutes, and at various applied time ranging from 60 to 240 minutes. Evaluation of electrolytic corrosion was carried out by Tafel extrapolation, weight loss, surface analysis after the experiment. In the electrolytic corrosion characteristics of Al5083-H321 as the current density increased, the surface damage tended to proportionally increase. In the current density of $0.01mA/cm^2$ for a applied long time, the damage tended to grow on the surface. In the case of $10mA/cm^2$ current density for a applied long time, the damage progressed to the depth direction of the surface, and the amount of weight loss per hour increased to 4 mg/hr.

Influence on a density of micro-scale dimple for surface texturing on friction control (마찰제어를 위한 Surface texturing의 Micro-scale dimple 밀도영향)

  • Chae, Young-Hun;Kim, Seock-Sam
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.945-950
    • /
    • 2004
  • Surface texturing of tribological application is another attractive technology of friction reducing. Also, reduction of friction is therefore considered to be a necessary requirement for improved efficiency of machine. In this paper attempts to investigate the effect of density for micro-scale dimple pattern on bearing steel flat mated with pin-on-disk. We demonstrated the lubrication mechanism for a Stribeck curve, which has a relationship between the friction coefficient and a dimensionless parameter for lubrication condition. It is found that friction coefficient is depended on the density of surface pattern. It was thus verified that micro-scale dimple could affect the friction reduction.Lubrication condition regime has an influence on the friction coefficient induced the density of micro dimple.

  • PDF